D. Deodorizing Control
i. Control condition
Control at cooling/dry operation and auto fan speed.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
ii. Operation
The odor status is arranged as below and it is shifted as follow.
* When COMP is ON
* When COMP is OFF
* Start from 4 if the Thermostat is OFF during the start operation.
Odor Status
Status Shift
according to COMP
Status Shift
according
to time (s)
Fan Speed
8.1.8.
Outdoor Fan Motor Operation
Outdoor fan motor is operated with one fan speed only. It starts when compressor starts operation and it stops 30 seconds after
compressor stops operation.
8.1.9.
Airflow Direction
1. There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vertical vanes).
2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature
and intake air temperature) and manual (angles of direction can be adjusted using remote control).
(Shift to 4 when COMP is OFF)
(Shift to 1 when COMP is ON)
1
2
ON
Cooling
zone
40
50
Dry zone
Cooling
zone
OFF
SSLo
Dry zone
1 → 2 → 3
4 → 5 → 6 → 7 → 6 ←→ 7
3
4
5
30
90
Auto Fan Speed
SSLo
OFF
SLo
28
6
7
6.7.6...
OFF
20
90
20.90.20...
SSLo
OFF
SSLo.OFF...
1
ON
ON