4.6 Diagnostic
Diagnostics values are written to
of the record is in following table:
Registers
Caption
DiagCnct
D3500.0
DiagRQueue
D3500.1
D3500.8-15
DiagGsmReg
DiagSigQuality
D3501.0-7
D3501.8-15
DiagSigErr
D3502
DiagAlive
D3503
DiagVersion
D3504
0x0000
DiagReset
D3505
D3506
DiagAtFlag
D3508-D3509
DiagUpTime
Gprs ...
D3510-D3529
D3530-D3539
DiagOperator
D3540-D3549
DiagCredit
DiagAtCmd
D3550-D3699
This range of registers cannot be used for any other purposes!
D3500.x
Notation
means x-th bit of D3500 register. For example D3500.0 is the
least significant bit in register D3500. Another example D3500.8-15 are eight most
significant bits in register D3500 (high byte).
Base of
Diag Record
(D3500) may be changed to another D or R register via
configuration key REGDIAG.
5. Configuration
5.1 How to
Configuration for CMGSM is located inside PLC Fatek. Range of internal PLC registers
D3900 – D3999 is used. Configuration itself is a string of characters. This string is
created via WinProladder (software from PLC FATEK manufacturer), see following
images. This range of registers cannot be used for any other purposes!
140903 FBs-CMGSM User's Manual EN v3-04
PLC1.ir
Diagnostic Record
, standard base D3500. Structure
Description
0=no connection to PLC, 1=connection to
PLC OK
0=no SMS in receive queue, 1=at least one
SMS in receive queue
result of command AT+CREG:
0=not registered, not searching
1=registered, home network
2=not registered, searching
3=registration denied
5=registered, roaming
Signal quality in percent (0-100) or 255 if
unknown.
Signal BER (0-7) or 255 if unknown.
CMGSM writes value 0x0001 whenever
diagnostic record is refreshed (cca 6
seconds). This is intended for PLC program
to check if CMGSM is alive. In this case PLC
program will write a 0x0000 into this
register and wait for 0x0001 here.
Version of CMGSM3, in high byte is high
version number, in low byte is low byte is
low version number
For future use
If PLC writes value 0xF3A5 to this register
the CMGSM will make reset of itself.
0x0000 – Idle
0x0001 – Execute
command
DiagAtCmd (written by program in PLC)
0x0003 – Command is about to execute
(written by CMGSM)
0x0000 – Command executed successfully
(written by CMGSM)
0x0004 – Exception while executing the
command (written by CMGSM)
32 bit counter which is incremented
whenever CMGSM updates DiagRegisters
area in PLC. The counter is cleared after
restart of CMGSM. The counter value
indicates in a certain way how long the
CMGSM is running without restart (so
called Uptime).
Reserved for GPRS diagnostics
See chapter "TCP over GPRS" for details
String
with
name
of
operator
registered. Empty string if not registered.
Length 20 characters.
Reserved
Sending AT commands to modem directly.
Write a command to this place and set
D3506 (DiagAtFlag) to 0x0001. Command
is executed and result is placed in this
place (overwriting original command). In
D3506 (DiagAtFlag) is signalized end of
execution. The system is the same as with
sending SMS.
Step 1 – Right click on Table edit - ASCII Table
in
Step 2 – Enter Table Name „cfg" and Table starting address „D3900".
when
Step 3 – Enter configuration string
"CMGSM3;PIN=7608;ACODE=998877;$" into field "ASCII Editor" and
click on button "Output Preview". !!! Warning: Change PIN according your
Step 3 (GPRS) – Enter configuration string
"CMGSM3;PIN=7608;APN=internet;SERVER=test.server.com;PORT=5700
;ACODE=998877;$" into field "ASCII Editor" and click on button "Output
Preview". !!! Warning: Change PIN according to your real SIM card !!!
and select "New ASCII Table"
Then click "OK".
real SIM card !!!