  • Page 1 cordfree spot – on® Instructions for Use...
  • Page 3: Dear Customer

    GmbH & Co. KG [hereinafter referred to as orangedental] only considers itself responsible for the effects on safety, reliability and performance of the device if: Assembly, add-ons, readjustments, alterations or repairs are carried out by persons authorised by orangedental.
  • Page 4: Responsibility Of The Operator

    spot – cordfree Instructions for Use | on® 1.1.2. Responsibility of the Operator The operator is among other things responsible for: compliance with accident prevention regulations and the Ordinance on the Installation, Operation and Use of Medical Devices (German regulation - MPBetreibV). the operation.
  • Page 5: Table Of Contents

    spot – cordfree Instructions for Use on® 1.2. Contents Dear Customer ....................1 1.1. Prologue ......................1 1.1.1. Responsibility of the Manufacturer ............1 1.1.2. Responsibility of the Operator ..............2 1.2. Contents ......................3 1.3. Conventions, Symbols used ................4 About the Product ..................
  • Page 6: Conventions, Symbols Used

    spot – cordfree Instructions for Use | on® 7.3.6. Compliance with standards ..............24 7.3.7. Environmental conditions ................ 24 7.3.8. Electromagnetic compatibility ..............25 1.3. Conventions, Symbols used In these instructions, the conventions stated below indicate important information: This symbol is used if deviating from the procedure described ARNING may result in physical injury or death.
  • Page 7 spot – cordfree Instructions for Use on® RDER NUMBER This symbol indicates the order number. ERIAL NUMBER This symbol is used to indicate the serial number. CE M ARKING This symbol, attached by the manufacturer, indicates that the medical device is in conformity with and fulfills all requirements of the medical device directive 93/42/EEC.
  • Page 8: About The Product

    spot – cordfree Instructions for Use | on® ABOUT THE PRODUCT cordfree spot – is characterised by the fact that the battery is attached on® directly to the lighting unit and therefore no cable is required. cordfree Another special feature of spot –...
  • Page 9: Scope Of Delivery

    Allen key Charging unit 2.3. Accessories The following parts below can be reordered from orangedental GmbH & Co KG via your depot under the article number indicated. 1 battery unit ArtNr. zublup0499500 1 Orangefilter ArtNr. zublup0499440 00.008.133-01 | EN...
  • Page 10: Installation

    AUTION being inserted, please disconnect the charging unit from the mains plug and no longer use the charging unit. Get in touch with orangedental. Figure 1: charging batteries Note: Do not use a USB port on your PC for charging. This cannot...
  • Page 11 Figure 2: Inserting the battery If no adapter is attached to the magnifying glasses yet, Note: please use the supplied Allen key or contact orangedental if necessary. 00.008.133-01 | EN Datum: 23.11.2018 Seite 9 von 30...
  • Page 12: Usage

    spot – cordfree Instructions for Use | on® USAGE Switching on Insert a battery into the lighting unit (see 3: Installation). The LED now lights up for one second. During this time, the touch sensor is calibrated and should therefore not be touched. cordfree spot –...
  • Page 13 AUTION being inserted, please disconnect the charging unit from the mains plug and no longer use the charging unit. Contact orangedental. Do not use a USB port on your PC for charging. The USB port Note: cannot provide the required power. Normally the USB interface in the computer switches off due to overload.
  • Page 14: Settings

    spot – cordfree Instructions for Use | on® 4.1. Settings 4.1.1. Adjusting the brightness The factory setting is a luminous intensity of 10,000 lux. To change the light intensity, press the touch sensor six times when it is switched on (the light is switched off and on again three times).
  • Page 15: Automatic Switch-Off

    spot – cordfree Instructions for Use on® 4.1.2. Automatic switch-off cordfree spot – has a function that ensures that the lighting unit is on® automatically switched on or off depending on its orientation. This allows you to illuminate your working area in your working position with your head slightly bent forward, while for an angle greater than α...
  • Page 16 spot – cordfree Instructions for Use | on® Changing the switch-off angle or deactivating the automatic switch-off function spot – cordfree If you want to change the switch-off angle, put on the on® switch it on. Within the next 15 seconds, tap twice from the side on one of the temples with your index finger and middle finger ("double tap").
  • Page 17 spot – cordfree Instructions for Use on® If the double tap has not been registered by the motion Note: cordfree sensor, the spot – may switch to the setting mode on® "brightness". Set the desired brightness and then follow the instructions again as described in Section 4.1.2: Changing the switch-off angle.
  • Page 18: Assembly Of Spare Parts And Accessories

    spot – cordfree Instructions for Use | on® ASSEMBLY OF SPARE PARTS AND ACCESSORIES 5.1. Mounting the orange filter 1. Make sure that the pre-assembled grub screw does not protrude into the inside of the orange filter. cordfree 2. Place the orange filter on the spot –...
  • Page 19: Safety, Handling And Maintenance

    spot – cordfree Instructions for Use on® SAFETY, HANDLING AND MAINTENANCE 6.1. General cordfree spot – Keep in mind that the shines very brightly and warms up on® cordfree spot – during operation. When using the , make sure that you do on®...
  • Page 20: Hygiene

    spot – cordfree Instructions for Use | on® Only use the supplied battery units and charging unit to charge the batteries. Keep small cells and batteries that could be swallowed out of the reach of children. Ingestion may result in burns, perforation of soft tissue and death.
  • Page 21: Disinfection

    spot – cordfree Instructions for Use on® First, remove any residue by wiping with a mild detergent. Now remove any residues of the cleaning agent with moist, lint-free disposable cloths. 6.2.2. Disinfection cordfree The subsequent disinfection of the spot – is carried out as wipe on®...
  • Page 22: Disinfectants For Spot - On® Cordfree

    spot – cordfree Instructions for Use | on® Disinfectants for spot – on® cordfree 6.2.3. The following products have been tested for disinfection of spot – cordfree on® Innocid DW-i disinfecting tissues PRISMAN Pharma International AG; Am Stalden 16; CH-4622 Egerkingen Omnizid Spray and wipe disinfection OMNIDENT Dental-Handelsgesellschaft mbH;...
  • Page 23: Maintenance And Servicing

    Please contact your dental dealer or enretec GmbH (www.enretec.de) to arrange a return of the device. Please contact orangedental GmbH & Co. KG if you have any questions in this regard. 00.008.133-01 | EN Datum: 23.11.2018...
  • Page 24: Spezificatons, Conformity

    – cordfree Instructions for Use | on® SPEZIFICATONS, CONFORMITY orangedental GmbH & Co. KG Aspachstraße 11 | 88400 Biberach / Riß 7.1. Requirements for the practical environment cordfree spot – may only be operated by qualified and on® MPORTANT trained persons.
  • Page 25: Technical Data

    spot – cordfree Instructions for Use on® 7.3. Technical data 7.3.1. Dimensions data unit Housing battery unit 27 x 16 ⌀ Housing lighting unit 32 x 17 ⌀ Housing charging unit 80 x 46 x 15 Weight battery unit Weight lighting unit Weight charging unit 7.3.2.
  • Page 26: Emc Classification

    spot – cordfree Instructions for Use | on® 7.3.5. EMC Classification Data EN 60601-1-2 uses HF energy exclusively for its internal function Group 1 EN 60601-1-2 is suitable for use in all establishments, including residential areas and those directly connected to Class B a public supply network which also supplies buildings used for residential purposes.
  • Page 27 spot – cordfree Instructions for Use on® 7.3.8. Electromagnetic compatibility Guidance and manufacturer’s declaration – electromagnetic emissions cordfree spot – is intended for use in an environment as described on® cordfree spot – below. The customer or the user of the should assure that on®...
  • Page 28 spot – cordfree Instructions for Use | on® Guidance and manufacturer’s declaration – electromagnetic immunity cordfree spot – is intended for use in the electromagnetic on® cordfree spot – environment specified below. The customer or the user of on® should assure that it is used in such an environment. Immunity test IEC 60601 Compli-...
  • Page 29 spot – cordfree Instructions for Use on® Mains power quality < 5 % UT Voltage dips, (>95 % dip applicable should be that of a typical short in U commercial or hospital interruptions environment. for ½ cycle and voltage variations on 40 % UT power supply (60 % dip in...
  • Page 30 spot – cordfree Instructions for Use | on® Guidance and manufacturer’s declaration – electromagnetic immunity cordfree spot – is intended for use in an environment as described on® cordfree below. The customer or the user of the spot – should assure that on®...
  • Page 31 spot – cordfree Instructions for Use on® Interference may occur in the vicinity of equipment marked with the following symbol. NOTE 1: At 80 MHz and 800 MHz the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
  • Page 32 spot – cordfree Instructions for Use | on® Recommended separation distances between portable and mobile RF cordfree spot – communications equipment and the on® cordfree spot – is intended for use in an electromagnetic on® environment in which radiated RF disturbances are controlled. The cordfree spot –...

Table of Contents