Download Print this page

PARK WAREHOUSE 605wf100-2 Installation Manual

Outdoor bottle filling station floor mount

Advertisement

Quick Links

Outdoor
Bottle
Filling
Station
Floor
Mount
SKU:
605wf10
0-2
Installation
INSTALLER
To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR
COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After
installation, leave these instructions with the Fountain for future reference.
PAGE 1

Advertisement

loading

Summary of Contents for PARK WAREHOUSE 605wf100-2

  • Page 1 Outdoor Bottle Filling Station Floor Mount SKU: 605wf10 Installation INSTALLER To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT! INSTALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING.
  • Page 3 SUGGESTED SITE PREPARATION DETAIL FOR WHEN USING THE SANITARYFR1 VALVE 4" PVC 1/4 BEND (SUPPLIED BY INSTALLER) 1-1/2" DRAIN TUBE (SUPPLIED BY INSTALLER) 4" PVC PIPE (SUPPLIED BY INSTALLER) CONCRETE SLAB CLEANOUT PLUG FOR ACCESS 4" (SUPPLIED BY INSTALLER) 102mm MIN.
  • Page 4 (6) 1/2" (13mm) DIA. HOLES EQUALLY SPACED ON A 12" ( 305mm ) BOLT CENTER 1-1/4 DRAIN TUBE SUPPLIED WITH FTN. AIR GAP ASSY. SUPPLIED WITH VALVE O 14" 356mm 10" 254mm 3" 76mm 14 9/16" 371mm 64" 1626mm 1-1/2 DRAIN TUBE SEE DETAIL A SUPPLIED BY INSTALLER 44"...
  • Page 5 FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN Step 1 - Insert the 1/8” O.D. tube (Label A) into the connector (provided with fountain). Insert the 1/8” O.D. tube coming from the fountain push button actuator into the connector. Trim any excess length. Step 2 - Secure the 1/8”...
  • Page 6 3, 11 FIG. 4 FIG. 5 PAGE 6...
  • Page 7: Parts List

    The Following Items are included with the SanitaryFR1 Valve PARTS LIST ITEM NO. PART NO. DESCRIPTION 110175443890 Hex Nut - 3/8-16 45806C Single Valve 50986C Regulator Holder 56082C Regulator Nut 56092C Poly Tubing - 1/4” (Cut To Length) - To Bubbler 56123C Poly Tubing - 1/8”...
  • Page 8: Troubleshooting And Maintenance

    TROUBLESHOOTING AND MAINTENANCE Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button. Place finger over air outlet. Push button to test diaphragm. Tighten diaphragm cap screws. Replace diaphragm if necessary.
  • Page 9 21, 22 24, 24a, 24b 22, 23 22, 23 Included with Sanitary Valve The Following Items are included with the Fountain PARTS LIST ITEM NO. PART NO. DESCRIPTION 1000003814* Cover - Round Plate 45931C Outdoor Bottle Filler Drain Plug 1000003812* Access Panel 98901C Kit - FR Push Button/Sleeve/Nuts...