Advertisement

Quick Links

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information on installation, operating,
maintenance, trouble shooting & replacement parts for:
FX SERIES:
FX-1-290
FX-2WS-290
FX-1A-290
FX-2WSA-290
FX-1UC-290
FX-2WSRE-290
FX-1RE-290
FX-2WSREA-290
FX-1REA-290
FX-2UCB-290
FX-3SS-290
• 2N1-Two Cooling Systems in one:
- Refrigerator (40ºF)
- Freezer (-5º to 0ºF)
- Or anywhere in between (-5º to 40ºF)
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
WARNING / FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING
R290 flammable refrigerant in use. Improper installation,
adjustment, alteration, service or maintenance can cause
property damage, injury or death. Read the installation,
operating and maintenance instructions thoroughly before
installing or servicing this equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
PART NUMBER PP MNL1701, REV E (08/17)
FX-1CS-290
FX-1CS-60-290
FX-2SC-290
FX-1CS-52-290
FX-1CSRE-290
FX-2CSRE-290
888-994-7636, fax 888-864-7636
unifiedbrands.net

Advertisement

Table of Contents
loading

Summary of Contents for Unified Brands Randell FX Series

  • Page 1 Unified Brands suggests that if you are suspicious of damage to make a notation on the delivery receipt. It will be the responsibility of the consignee to file a claim with the carrier.
  • Page 2: Table Of Contents

    Table of Contents Important Operator Notices ............page 3 Labeling ..................page 4-5 Equipment Description ..............page 6 Installation ..................page 7 Operation ................page 8-9 Maintenance ................page 10 Troubleshooting ................page 11 Service ..................page 12 Parts List ................page 13-16 Electrical Schematic ..............
  • Page 3: Important Operator Notices

    In addition, all Unified Brands food service equipment is backed by some of the best warranties in the food service industry and by our professional staff of service technicians.
  • Page 4: Labeling

    Labeling The following warning labels will be found on your equipment: INTERIOR EVAPORATOR COVER NEAR MACHINE COMPARTMENT AND NAMEPLATE OM-FX SERIES...
  • Page 5 Labeling EXTERIOR OF UNIT NEAR EXPOSED REFRIGERANT TUBING OM-FX SERIES...
  • Page 6: Equipment Description

    Equipment Description FX-1-290 43.3” 28” 36” 0.88 1.65 1/4(1) 115/60/1 5-15P(1) FX-1A-290 43.3” 28” 14.7” 0.79 1/4(1) 115/60/1 5-15P(1) FX-1UC-290 27” 29.5” 33.2” 2.83 0.75 1.83 1/4(1) 115/60/1 5-15P(1) FX-1RE-290 16.3” 0.88 1.65 1/4(1) 115/60/1 5-15P(1) 35” 34.5” FX-1REA-290 35” 34.5”...
  • Page 7: Installation

    NOTE: VOLTAGE PROTECTION AND WILL NOT Damage to equipment may result if not followed. Unified Brands is not responsible OUTPUT VOLTAGE TO THE COMPRESSOR IF for damage to equipment if improperly installed.
  • Page 8: Operation

    Unit is designed for normal operating temperatures are between 70-100°F. Operating outside of those temperatures may cause premature product wear or failure Unified Brands has attempted to preset the temperature control to ensure that your unit runs at an optimum temperature, but due to varying ambient conditions, including elevation, food type and your type of operation, you may need to alter this temperature using control adjustment until desired temperature is reached.
  • Page 9 Operation CHANGE FROM ºF /ºC : 1. Press the up/down buttons simultaneously for 5 seconds to access the menu. 2. Password is requested. Password is 000. 3. Press the bottom left button to OK the password. 4. Using the up/down buttons, navigate to the “diS” level. Press the bottom left button to OK the selection.
  • Page 10: Maintenance

    For a complete listing of current Unified Brands ASA please visit www.unifiedbrands.net. Unified Brands believes strongly in the products it manufactures and backs those products with one of the best warranties in the industry. We believe with the proper maintenance and use, you will realize a profitable return on your investment and years of satisfied service.
  • Page 11: Troubleshooting

    Troubleshooting This unit is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are found at the end of this manual. SYMPTOM POSSIBLE CAUSE PROCEDURE No power to unit...
  • Page 12: Service

    Service CAUTION! This piece of equipment uses a R290 Refrigeration system. This equipment has been COMPONENT PARTS SHALL BE REPLACED clearly marked on the serial tag the type of refrigerant that is being used. There is also a WITH LIKE COMPONENTS. SERVICE WORK warning labels stating that the unit contains R290 refrigerant.
  • Page 13: Parts List

    Parts List ITEM PART NUMBER DESCRIPTION RF FAN0601 FAN. AXIAL, 127 X 38MM 120 CFM,115V CONDENSER FA BLT0349 BOLT, 6-32x1/2 T/H/P 18-8 SS 08BC PHILLIPS TRUSS SS FA NUT0312 RIVNUT, 6-32 THD RF CMP1604 COMPRESSOR, 3/8 HP, LO, 404, 115V, DANFOSS RF CMP1604SC COMPRESSOR START COMPONENTS RF FLT9902...
  • Page 14 Parts List ITEM PART NUMBER DESCRIPTION HD CST9801 2.5" SWIVEL CASTER (NO LOCK)--HD CST9801 HD CST200 2.5” SWIVEL CASTER (NO LOCK)--HD CST200 HD CST9802 2.5" SWIVEL CASTER (WITH LOCK)--HD CST9802 HD CST201 2.5” SWIVEL CASTER (WITH LOCK)--HD CST201 RP PNL1702 PANEL BACK MACHINE COMP RP END1701 SIDE, EXTERIOR, S/S, RIGHT...
  • Page 15 Parts List ITEM PART NUMBER DESCRIPTION RP PAN0705 INSULATED DRAWER TUB FOR FX-1, FX-1RE RP PAN0706 INSULATED DRAWER TUB FOR FX-1A, FX-REA RP PAN0801 INSULATED DRAWER TUB FOR FX-1UC RP GSK0604 GASKET, MAGNETIC, SLIDE SEAL, PF, 765 X 614mm RP DWR1603 DRAWER CARRAIGE ASSY W/FRONT, FX-1, FX-1RE RP DWR1504 DRAWER CARRIAGE ASSY W/FRONT, FX-1UC...
  • Page 16 Parts List ITEM PART NUMBER DESCRITPION RP DRP0602 EVAPORATOR DRAINING DRAIN PAN W/DEFROST ELEMENT PB ELB0313 ELBOW, 1/2" ID X 3/8" ID 90 CU CXC EL PAD1101 PAD, FLEXIBLE HEATING FOIL 6.9" X 15.75" 150W 120V RF COI0603 COIL, 1.00" X 7.00" X 15.7" STAGED FIN EVAPORATOR RP BRK0704 BRACKET FOR HI-LIMIT RF TRM0501...
  • Page 17: Electrical Schematic

    Electrical Schematic OM-FX SERIES...
  • Page 18: Service Log

    Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM-FX SERIES...
  • Page 19: Warranty Policies

    NOTE: warranties are effective from date of shipment, with a thirty day window to allow for shipment, installation and set-up. In the event equipment was shipped to a site other than the final installation site, Unified Brands will warranty for a period of three months following installation, with proof of starting date, up to a maximum of fifteen months from the date of purchase.
  • Page 20 Unified Brands recommends thorough cleaning of gaskets on a weekly basis with a mild dish soap and warm water. With proper care Unified Brands gaskets can last up to two years, at which time we recommend replacement of all gaskets on the equipment for the best possible performance.
  • Page 21 Appearance of damage will require removing the crate in the presence of the driver. A notation must be placed on the freight bill and signed for by the truck driver at the time of delivery. Any and all freight damage that occurs to a Unified Brands piece of equipment as a result of carrier handling is not considered under warranty, and is not covered under warranty guidelines.

Table of Contents