Download Print this page
Unified Brands Randell 2127AC Operator's Manual

Unified Brands Randell 2127AC Operator's Manual

Air-curtain refrigerator

Advertisement

Quick Links

OPERATOR'S MANUAL
This manual provides information on
installation, operating, maintenance,
trouble shooting & replacement
parts for
2127AC
2127PAC
TAS PTAC
AIR-CURTAIN
REFRIGERATOR
NOTIFY CARRIER OF DAMAGE AT ONCE.
It is the responsibility of the consignee to inspect
the container upon receipt of same and to
determine the possibility of any damage, including
concealed damage. Randell suggests that if you
are suspicious of damage to make a notation on
the delivery receipt. It will be the responsibility of
the consignee to file a claim with the carrier. We
recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be
current and accurate at the time of printing/creation.
Unified Brands recommends referencing our product line
websites, unifiedbrands.net, for the most updated
product information and specifications.
8/17/2015
PP MNL1501

Advertisement

loading

Summary of Contents for Unified Brands Randell 2127AC

  • Page 1 Manufacture Service/Questions 888-994-7636. Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications. 8/17/2015...
  • Page 3: Table Of Contents

    Table of Contents page 2…………………… Table of Contents & Congratulations page 3……………………………………Parts & Service Hotline page 4………………………………...…Serial Number Location page 5-9……………………………….Randell Limited Warranty page 10……………………………………..…Unit Specifications page 11-12…………………………………..……Unit Installation page 13-14..……………………………………..Unit Operation page 15-16…………………...Control Settings and Instructions page 17-18……………………………..Preventive Maintenance page 19………………………………………..Electrical Diagram page 20……………………………………..……Troubleshooting page 21-22…………………………….…….Replacement Parts...
  • Page 4: Serial Number Location

    In addition, all Randell food service equipment is backed by some of the best warranties in the food service industry and by our professional staff of service technicians. Retain this manual for future reference. NOTICE: Due to a continuous program of product improvement, Randell reserves the right to make changes in design and specifications without prior notice.
  • Page 5 Warranty Policies Congratulations on your purchase of a Randell Manufactured piece of equipment. Randell believes strongly in the products it builds and backs them with the best warranty in the industry. Standard with every unit is the peace of mind that this unit has been thoroughly engineered, properly tested and manufactured to excruciating tolerances, by a manufacturer with over 30 years of industry presence.
  • Page 6 Warranty Policies con’t Temperature adjustments are not covered under warranty, due to the wide range of ambient conditions. To request a warranty approval number, call our Field Service Department at: 1-800-621-8560 WHEN OPTIONAL 5 YEAR COMPRESSOR WARRANTY APPLIES 1. Provide reimbursement to an ASA for the cost of locally obtained replacement compressor in exchange for the return of the defective...
  • Page 7 Warranty Policies con’t ITEMS NOT COVERED UNDER WARRANTY 1. Maintenance type of repairs such as condenser cleaning, temperature adjustments, clogged drains and unit leveling. 2. Randell does not cover gaskets under warranty. Gaskets are a maintenance type component that are subject to daily wear and tear and are the responsibility of the owner of the equipment.
  • Page 8 Warranty Policies con’t STORAGE CHARGES Randell makes every effort to consistently meet our customer’s shipment expectations. If after the equipment has been fabricated, the customer requests delay in shipment, and warehousing is required: 1. Equipment held for shipment at purchasers request for a period of 30 days beyond original delivery date specified will be invoiced and become immediately payable.
  • Page 9 Warranty Policies con’t RETURNED GOODS Authorization for return must first be obtained from Randell before returning any merchandise. Any returned goods shipment lacking the return authorization number will be refused, all additional freight costs to be borne by the returning party. Returned equipment must be shipped in original carton, freight prepaid and received in good conditions.
  • Page 10: Unit Specifications

    Unit Specifications 2127AC Air Curtain Single Door Refrigerator. Model 2127AC shown. Air Curtain Pass Through Refrigerator. Model TAS PTAC shown. 888-994-7636...
  • Page 11: Unit Installation

    Unit Installation SELECTING A LOCATION FOR YOUR NEW UNIT The following conditions should be considered when selecting a location for your unit: 1. Floor Load: The area on which the unit will rest must be level, free of vibration, and suitably strong enough to support the combined weights of the unit plus the maximum product load weight 2.
  • Page 12 Unit Installation con’t ELECTRICAL SUPPLY: Any wiring should be done by a qualified electrician in accordance with local electrical codes. A properly wired and grounded outlet will assure proper operation. Please consult the data tag attached to the compressor to ascertain the correct electrical requirements. Supply voltage and amperage requirements are located on the serial number tag located inside the mechanical housing.
  • Page 13: Unit Operation

    Unit Operation When the door is open, the air curtain design directs cold ais across the cabinet opening, keeping the ambient air out and cold air in the cabinet for approximately 45 minutes. The unit will maintain 45°F box temperature at 70°F ambient with the door open, quickly returning to normal refrigerated temperatures of 36°F with the door closed.
  • Page 14 Unit Operation con’t AMBIENT CONDITIONS 1. This unit is designed for operation in a room ambient of 70°F and 55% relative humidity or less. It should never be used outside or located in direct sunlight. Randell has attempted to preset the temperature control to ensure that your unit runs at an optimum temperature, but due to varying ambient conditions, including elevation, food type and your type of operation, you may need to alter this temperature.
  • Page 15 Control Settings Rande ll Control Se ttings by Rande ll 2127AC M ode l N umbe r Product Line Air Curtain X R02CX 2127AC Randell Purchased Part # RF CNT0501 (brought in un-programmed) Randell Programmed Part # RP CNTxxx RP CNT1401 (model specific) Modifications (Shown in RED) Locked...
  • Page 16 Control Settings con’t DIXELL CONTROL SETTING INSTRUCTIONS HOW TO CHANGE A PARAMETER VALUE To change the parameter’s values operate as follows: 1. - Enter the Programming mode by pressing the Set and Down Arrow for 3 seconds (the defrost and water drops symbol will start blinking) 2.
  • Page 17: Preventive Maintenance

    Preventive Maintenance Randell strongly suggests a preventive maintenance program which would include the following Monthly procedures: 1. Cleaning of all condenser coils. Condenser coils are a critical component in the life of the compressor and must remain clean to assure proper air flow and heat transfer.
  • Page 18 Preventive Maintenance (cont.) RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INCLUDE THE FOLLOWING: CLEANING AGENT COMMENTS Soap, ammonia, detergent Routine cleaning Apply with a sponge or cloth Medallion Fingerprints and smears Arcal 20, Lac-O-Nu, Ecoshine Provides a barrier film Stubborn stains and Cameo, Talc, Zud, First Rub in the direction of the discoloration...
  • Page 19: Electrical Diagram

    Electrical Diagram randellfx.com...
  • Page 20 Trouble Shooting Guide SYMPTOM POSSIBLE CAUSE PROCEDURE Unit doesn't run 1. No power to unit 1. Plug in unit 2. Power switch in OFF position 2. Switch power switch to ON 3. Temperature control turned off 3. Check temperature control 4.
  • Page 21: Replacement Parts

    Replacement Parts Call factory for replacement parts. Randell Service and Parts 800-621-8560 Hotline randellfx.com...
  • Page 22 Replacement Parts (cont.) 888-994-7636...
  • Page 23: Notes

    NOTES randellfx.com...

This manual is also suitable for:

Randell 2127pacRandell tas ptac