panels, etc. Any error in reassembly or wiring can result in electrical leakage, flame, etc.,
and may be hazardous.
9. NEVER remodel the product in any way. Remodeling can result in improper operation,
malfunction, or electrical leakage and flame, which may be hazardous.
10. Touch current check. (After completing the work, measure touch current to prevent an
electric shock.)
Plug the AC cord directly into the AC outlet. Do NOT use an isolation transformer for
this check.
Connect a measuring network for touch currents between each exposed metallic part
on the set and a good earth ground such as a water pipe.
Resistance values in orms (Ω).
V: Voltmeter or oscilloscope
(r.m.s. or peak reading)
Input resistance :
Input capacitance :
Frequency range : 15 Hz to 1 MHz and d.c. respectively
Note: Appropriate measures should be taken to obtain the correct value in case of
non sinusoidal waveforms.
The measuring instrument is calibrated by comparing the frequency factor of
the solid line in figure F.2 of IEC 60990 at various frequencies. A calibration curve is
constructed showing the deviation of
frequency.
TOUCH CURRENT =
The potential at any point (TOUCH CURRENT) expressed as voltage
not exceed the following value:
Annex D
(normative)
Measuring network for TOUCH CURRENTS
1 MΩ
200 pF
from the ideal curve as a function of
/ 500 (peak value).
with
and
does