Page 1
Power Anytime, Anywhere Tesla TI3560 12-24 GPU ™ Ground Power Unit User Manual Built Smart...Proven Tough Tesla Industries, Inc. 101 Centerpoint Blvd. New Castle, DE 19720 (302) 324-8910 Phone (302) 324-8912 Fax www.teslaind.com...
Page 2
Any attempts to open or examine the inside of the TI3560 12-24 GPU via a tool or device (borescope, probe, etc.) can result in unit failure and/or injury by electrical shock. This GPU is mainte nance free and should not be opened or disassembled for any reason.
Page 3
™ Ground Power Unit (GPU) and Micro Power Unit (MPU) Containing Dry Cell (Starved Electrolyte) Batteries Used on Aviation/Military Application Manufacturer’s Name and Address: Emergency Telephone Number: Tesla Industries Inc. (302)324-8910 101 Centerpoint Blvd. Fax: (302)324-8912 New Castle, Delaware 19720 www.Teslaind.com...
Page 4
Reactivity (Yellow) = 2 Sulfuric Acid is Water Reactive if concentrated. U.S. DOT: Tesla™ Industries GPU/MPU batteries are classifi ed as Nonspillable. They have been tested and meet the nonspillable criteria listed in 49 CFR § 173.159(f) and 173.159a(d)(1). Nonspillable batteries are excepted from 49 CFR Subchapter C requirements, provided that the following criteria are met: The batteries must be securely packed in strong outer packagings and meet the requirements of 49 CFR §...
3.6 – Temperature Specifications 3.7 – Environmental 3.8 – Normal Functional Test Procedures 16-17 3.9 – Pre-Operation 3.10 – Transporting Unit 3.11 – Regulated 28.5 Vdc Ground Power 19-20 3.12 – Regulated AC Power 20-21 3.13 – Charging Unit TI3560 12-24 GPU...
Page 6
7.8 – 12 Vdc Output Loading Curves 34-35 Section 8 – Optional Accessories 8.1 – Shipping Case 8.2 – GPU Protective Covers 8.3 – Tesla™ AC Line Cords 8.4 – Cobra™ DC Replacement Contacts and Tools 8.5 – GPU Tires Appendix A 38-42...
Page 7
MΩ megaohm Minimum Micro Power Unit NEMA National Electrical Manufacturers Association Ω power factor power factor correction root-mean-square Total Harmonic Distortion TMDE Test, Measurement, & Diagnostic Equipment Unmanned aerial vehicle Volts, Alternating Current Volts, Direct Current watts TI3560 12-24 GPU...
The following symbols will appear within the warning triangles to alert the user to the specifi c type of danger or hazard. General Warning Electrical Hazard Explosion Hazard Fire Hazard Battery Warning Guard from Moisture Figure 1.2.1 – Different types of hazard and caution symbols TI3560 12-24 GPU...
(115V or 230V) matches the ac power source (hangar wall, fl ight line ac power) prior to connecting the unit for recharging. Figure 1.3.4 – TI3560 12-24 GPU witch Input Voltage Selector S TI3560 12-24 GPU...
150°F (65°C). This protects the unit from overheating and damage. If the unit shuts down, move the unit into a cooler environment such as shade or air conditioning when possible. Perform a full function test after the unit has been allowed to cool prior to use. TI3560 12-24 GPU...
This manual contains the complete operating instructions and procedures for the TI2560-12-24 Ground Power Unit. The TI3560 12-24 GPU has been designed to serve as a stand-alone source of dc electrical power for aircraft systems and ground support maintenance operations. Using a single 120 Vac power source, the TI3560 12-24 GPU will provide regulated outputs of 14.25 Vdc at 20 amps continuous and 28.5...
200 260 Vac. 24 Vdc Capacity Meter – Indicates the 24V battery Telescopic Handle – Allows for easy transport of charge state/power output status. unit. 12 Vdc Capacity Meter –Indicates the 12V battery charge state/power output status TI3560 12-24 GPU...
Ensure that ports are clear at all times. When the TI3560 12-24 GPU is plugged into AC power, the internal cooling system will efficiently regulate unit temperature regardless of load. At room temperature (+77°F) the exhaust air will not exceed the ambient temperature by more than 5°F.
Product Overview 2.7 – Operating Positions The TI3560 12-24 GPU can be operated in both the horizontal and vertical positions as shown. Make sure that the airflow is not obstructed from air intake and outlet. Front Inlet Rear Outlet Horizontal Position...
3. Reset breaker by pressing red button. 4. Reconnect ac and dc connections to the unit. The unit should power up automatically. If the breaker continues to trip, return the unit to Tesla™ Industries for repair. Figure 2.8.1 - AC Input Circuit Breaker (outlined in blue) 2.9 –...
2.12 – Input Voltage Selector Switch The Input Voltage Selector Switch allows the unit to operate safely within the expected voltage range of either 100 - 130 Vac or 200 - 260 Vac. Figure 2.12.1 Input Voltage Selector Switch (outlined in blue) TI3560 12-24 GPU...
Page 18
The 230 Vac setting accommodates the voltage range of 200-260 Vac. Figure 2.12.2 - Unscrew Protective Cover Figure 2.12.3 - Select Voltage Do not overtighten Selector Shield screws. Be sure star locks are on NOTE screws and snug the screw. Overtightening will damage the Selector Shield. TI3560 12-24 GPU...
“Push to Test” function. (If this sensor is tripped, allow ten minutes for unit to cool before operating “Push to Test” button.) Figure 2.13.1 - Pushing to Test STATUS STATUS STATUS Full Charge Half Charge No Charge TI3560 12-24 GPU...
Operating any electrical equipment in the presence of moisture creates possible horizontal. WARNING TI3560 12-24 GPU safety hazards and/or potential for equipment damage. Every effort has been made, within the scope of existing technology to prevent foreseeable safety hazards and make theunit moisture resistant to prevent damage or failure.
Unit inlet and outlet vent ports shall be covered from exposure. Unit shall be kept horizontal. It is recommended that the Tesla™ Protective Rain Cover be fi tted onto the unit to guard it from moisture (see Section 8). The limits...
Check for dents, punctures, case distortion or misalignment, and cracked or loose connec tors. If no damage is evident, proceed to the next step. If damage is evident, contact Tesla™ Industries, Inc. Check DC Voltage Reading at DC Receptacle Terminals To verify that the power cells are fully charged, set the digital multimeter to measure dc voltage.
Page 24
3.8.8 - Positive Probe to on the dc receptacle (shown in Figure 3.8.8). the AC Ground Post and the the Fastener Screw on the Multimeter should read less than 1 Ω. Positive Probe on the DC DC Receptacle. Positive Post. TI3560 12-24 GPU...
3.10 – Transporting Unit The TI3560 12-24 GPU has a telescoping handle that makes rolling the unit easy. For transporting on uneven ground, axle extensions should be added to the unit. For use on sand, balloon tires should be installed on the unit (see Optional Accessories).
Figure 3.11.3 Attaching an Aviation DC Power Cable vehicle to aircraft WARNING Do not allow alligator clamps to touch when connecting to dc power. Figure 3.11.4 - Connecting TI3560 12-24 GPU to AC Power Supply with DC Power Cable Attached TI3560 12-24 GPU...
Plugging in with AC Power When the TI3560 12-24 GPU is plugged into ac power, the output is 28.5 volts. This voltage allows the system to recondition and recharge the vehicle’s battery(ies). It is also an optimum voltage for powering avionics and lighting on most aircraft.
Until the unit is fully charged, the LED status will read half or no charge. Plug the TI3560 12-24 GPU into ac power to keep the cells charged whenever it is not in use, even if it is at Full Charge.
Section 4 – Post Operation 4.1 – General Although the TI3560 12-24 GPU has been ruggedized and made weather resistant within the scope of unit’s intended use, it is essential that good general care be taken to maintain unit in good operating condition and to maximize unit’s operational life.
Page 30
The TI3560 12-24 GPU’s power cells may be damaged if recharged by NiCad or Lithium Ion battery chargers. Power cells should only be charged by either the TI3560 12-24 GPU’s internal charger and the ac power cord furnished with the equipment, or when connected to aircraft’s external dc power receptacle.
Do not cut, crush, or drag the input or output power cables when handling the unit. Always inspect cables prior to use. If no damage is evident, proceed to the next step. If damage is evident, contact Tesla™ Customer Service. Do not attempt to use any other type of power cables other than the Tesla™ cables included with the unit.
Tesla™ Shipping Case (be sure to enclose the Repair Request Form). Seal the crate on all sides and return it to Tesla™ at the address listed below. Please contact Tesla™ Customer Service at (302) 324-8910 with any questions or concerns.
5. Will a Tesla™ Turbo Start™ spool up a turbine engine? Nothing will start a turbine engine faster or safer than the right Tesla™ Turbo Start™. Not only will it eliminate hot starts, but it will extend the life of your starter, your engine and your battery while reducing maintenance. The Turbo Start™ senses the impedance from the starter/generator.
Page 34
Unit should never be allowed to discharge fully. In-fi eld use, it receives a dc back charge directly from a running engine. When not in use, unit should be plugged into ac power (outlet) all the time. Tesla™ systems will retain 80% of their capacity after one year of storage.
Reset breaker by pressing red button. Reconnect ac and dc connections to the unit. (Plug in ac line cord on military unit.) The unit should power up automatically. If the breaker continues to trip, return the unit to Tesla™ Industries for repair. TI3560 12-24 GPU...
If LEDs still do not illuminate, Please contact Tesla™ Customer Service at (302) 324-8910. 2. Unit has no output dc or ac Units cells completely dead. Do a function check with digital meter, input or both.
Page 37
Switch breaker to ON position. Reconnect unit to cables and run. If LEDs still do not illuminate, Please contact Tesla™ Customer Service at (302) 324-8910. 8. Unit does not put out 28.5 Unit is not plugged in. Plug unit into ac power source to volts dc power.
These differences, however, are considered insignifi cant and are not individually accounted for. Ground Support and Aircraft Instrument Variations: The data shown in the performance charts do not account for instrument tolerance differences or inaccuracies. TI3560 12-24 GPU...
Performance Data 7.7 – Output Voltage TI3560 12-24 GPU 12 Vdc Output Voltage MINUTES 46 AMP CONSTANT CURRENT LOAD 7.8 – Maximum Output Current MAXIMUM OUTPUT CURRENT Maximum Output Current 3000 * * * * * * * * 2700...
The optional Shipping Case is the safest way to transport the AC line cords come in several lengths or can be custom-ordered to fi t your needs. Tesla™ specializes in TI3560 12-24 GPU. This custom case weighs 73 lbs and comes outfi tting cables with a variety of connectors and junction boxes.
Aviation Plug 400Hz Aviation Plug NSN: 5120-01-523-8761 (CL II) NSN: 5120-01-527-7729 (CL II) 8.5 – GPU Tires Tesla™ offers several tires in order to meet various customer mobility needs. TI21000-400 TI21000-203 Anti-FOD Flat-Free Tire Run-Flat Tire Rugged, puncture-proof, foam-filled tire.
Page 45
TI25000-005 United Kingdom Line Cord Czech, Republic of TI25000-003 Continental European Line Cord Denmark TI25000-300 Denmark Line Cord Djibouti, Republic of TI25000-003 Continental European Line Cord Dominica TI25000-005 United Kingdom Line Cord Dominican Republic TI25000-001 North American Line Cord TI3560 12-24 GPU...
Page 46
TI25000-001 North American Line Cord Japan 50/60 TI25000-001 North American Line Cord Jordan TI25000-005 United Kingdom Line Cord Kenya TI25000-005 United Kingdom Line Cord Korea, South TI25000-003 Continental European Line Cord Kuwait TI25000-005 United Kingdom Line Cord TI3560 12-24 GPU...
Page 47
TI25000-001 North American Line Cord Philippines TI25000-001 North American Line Cord Piccairn Islands (U.K.) TI25000-004 Old British Line Cord Poland TI25000-003 Continental European Line Cord Portugal TI25000-003 Continental European Line Cord Puerto Rico TI25000-001 North American Line Cord TI3560 12-24 GPU...
Page 48
TI25000-005 United Kingdom Line Cord Yemen TI25000-005 United Kingdom Line Cord Yugoslavia TI25000-003 Continental European Line Cord Zaire, Republic of TI25000-003 Continental European Line Cord Zambia TI25000-005 United Kingdom Line Cord Zimbabwe TI25000-005 United Kingdom Line Cord TI3560 12-24 GPU...
Page 49
APPENDIX A (Cont.) UNIVERSAL LINE CORD KIT FOR WORLDWIDE OPERATIONS NOTE: TESLA™ UNIVERSAL AC LINE CORD KIT, P/N: TI25000-U00, IS FOR UNITS ORIGINALLY BUILT WITH THE UNIVERSAL AC LINE CORD OPTION ONLY. THE AC ADAPTER OPTION IS TESLA™ P/N TI16000-19 AND MUST BE ORDERED WITH THE ORIGINAL PROCUREMENT OF UNIT(S).
Model #: ____________________________________ Serial #: ________________________________________ Shipping method to Tesla™: ______________________________________________________________________ Description of shipping package: ________________________________________________________________ Description of problem: _________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Return to Tesla™ Industries, Inc. 101 Centerpoint Boulevard, New Castle, DE 19720 Attention: Repair Department TI3560 12-24 GPU...
Page 51
Tesla™ Industries, Inc. 101 Centerpoint Blvd. New Castle, DE 19720 USA Tel: 302-324-8910 Fax: 302-324-8912 9475 Double R Blvd., Suite 2 Reno, NV 89521 Tel: 775-622-8801 Fax: 775-622-8810 www.teslaind.com...
Page 52
Using a single 120 Vac power source, it will provide both 12 Vdc and 24 Vdc continuous output power. In the field, it will produce up to 3000 peak amps — making the TI3560 a perfect solution for all of Power Anytime, Anywhere your ground power needs.
Page 53
143 minutes w/ac power TI7000-026 Shipping Case Weight 184.5 lbs (83.68 kg) Warranty 2 years (3-year optional) Tesla™ Industries, Inc. • 101 Centerpoint Blvd. New Castle, DE 19720 • 9475 Double R Blvd. Suite 2, Reno, NV 89521 USA • www.teslaind.com 11-13-14...