HST HD103B Installation And Maintenance Instructions

Conventional photoelectric smoke& heat detector

Advertisement

Quick Links

INSTALLATION AND MAINTENANCE INSTRUCTIONS
HD103B
Conventional Photoelectric Smoke& Heat Detector

SPECIFICATIONS

Operating Voltage Range:
Standby Current:
Maximum Alarm Current (LED on: ) ≤30mA @ 24 VDC
Operating Humidity Range:
Operating Temperature Range:
Smoke Sensitivity:
Fixed Temperature Rating:
Rate of Rise Detection:
Height:
Diameter:
Weight:

INSTALLATION

BEFORE INSTALLING

NOTICE: This manual should be left with the
owner/user of this equipment.
IMPORTANT: The detector must be tested and
maintained regularly following NFPA 72 requirements.
The detector should be cleaned at least once a year.

GENERAL DESCRIPTION

The device is photoelectronic detector uses a state of-the-
art optical sensing chamber. This detector is designed to
provide open area protection and to be used with most
conventional fire alarm control panel.
Two LEDs on each detector provide local 360° visible
alarm indication. They flash every 3~5 seconds indicating
that power is applied and the detector is working
properly. The LEDs latch on in alarm. LEDs will be off
when a trouble condition exists indicating that the
detector sensitivity is outside the listed limit. The alarm
can be reset only by a momentary power interruption.
9 to 28VDC Volts Non-polarized
≤60µA @ 24 VDC
10% to 93% Relative Humidity, Non-condensing
14°F to 120°F (-10°C to 49°C)
1.06±.26%FT.
135°F (57°C)
Responds to greater than 15°F/min
2.2˝ (55 mm) installed in Base
4.0˝ (103 mm)
5.5 oz. (155 g)
60mmm
INSTALLATION
NOTE: All wiring must conform to applicable local
codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that
the initiating-device circuits have been tested, and that the
wiring is correct.
Remove power from initiating-device circuits before
installing detectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor
into the base while turning it clockwise to secure it in
place.
3. After all sensors have been installed, apply power to
the control unit.
4. Test the sensor(s) as described in the TESTING
section of this manual.
5. Notify the proper authorities that the system is in

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD103B and is the answer not in the manual?

Questions and answers

Summary of Contents for HST HD103B

  • Page 1 INSTALLATION AND MAINTENANCE INSTRUCTIONS � HD103B Conventional Photoelectric Smoke& Heat Detector SPECIFICATIONS Operating Voltage Range: 9 to 28VDC Volts Non-polarized Standby Current: ≤60µA @ 24 VDC Maximum Alarm Current (LED on: ) ≤30mA @ 24 VDC Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range: 14°F to 120°F (-10°C to 49°C)
  • Page 2 operation. A. Smoke Entry test: Aerosol Generator (Gemini 501) The GEMINI model 501 aerosol generator can be used for smoke entry testing. Set the generator to represent B a s e t e r m i n a l 2 , 3 a r e s h o r t c i r c u i t i n s i d e t h e d e t e c t o r Z O N E + 4%/ft to 5%/ft obscuration as described in the GEMINI 501 manual.
  • Page 3 Please refer to insert for the Limitations of Fire Alarm Systems THREE-YEAR LIMITED WARRANTY We warrants its enclosed smoke detector to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture.

Table of Contents