TWIN FAN CONTENTS PAGE Introduction Safety Packaging Kits Unit Specification Exploded View Unit Location and Dropper Preparation 7 - 8 Dropper Installation Method A : Top Hat - Sheet Metal Section 9 - 10 Method B : Support Angles Fitting Flashing to Unit Mounted on Top Hat 11 - 12 Fitting Sump and Motor Fan Assembly 13 - 14...
TWIN FAN INTRODUCTION Please read this instruction book carefully prior to commencing the installation. Legal & Statutory Obligations Installation of this Coolbreeze Air Conditioner must conform to local building rules and regulations, electrical and plumbing codes, Environmental Protection Authority (EPA) rules and regulations, and all applicable Australia Standards and standards in the countries were CoolBreeze units are being installed.
TWIN FAN Packaging Kits The air-conditioning unit is supplied in kit form POWER PACK KIT Sump with components fitted Manifold Relevant Cables Tap Pack Installation Guide Paint (Only Australia) Support Brace CORNER / FILTER POST PACK LOUVRE PACK 4 Corner/2 Centre posts 6 Filter Pads 2 Large Louvre's 2 Feeder Pipes...
TWIN FAN Unit Location and Dropper Preparation Step 2 Unit Location Locate a minimum distance of 3 metres Step 1 from exhaust vents and chimneys. Locate the unit where it will receive plenty WARNING of fresh air, not in a recess where it may Smoke / toxic fumes chimneys are to be starved or where the air is polluted.
Page 8
TWIN FAN Unit Location and Dropper Preparation Dropper Preparation Only required if cascading units together Drill holes 46mm diameter Drilling Cable Entries Dropper Preparation - Multiple Twin Fan Units Drill three holes 46mm diameter in the dropper for the 2 x 240v cable For details on installing multiple Twin Fan and the 7 core keypad control ca- units in a string with a single controller see...
TWIN FAN METHOD A : Dropper Duct Installation using Top Hat - Sheetmetal Section Roof Penetration principles are the same Roof Penetration for all types of dropper mounting Check for location of roof truss and assess Find a suitable location and make the roof need for additional support brackets penetration Accurately position top-hats and secure to...
TWIN FAN Dropper Duct Installation using Top Hats continued Check that the dropper is square by meas- Accurate levelling of dropper is imperative uring the cross dimension on both sides for the proper function of the unit Measurement across the diagonal + 1300mm Once the angle is secured re-check the Proceed to secure angle onto the top hat...
TWIN FAN Fitting Flashing to unit mounted on Top Hats Bottom flashing gutter side Apply silicone between all metal surfaces and between all joins prior to placing in position. Fit flashing to lower part of roof Fit the first piece of the flashing and fix with Tek screw Re-caulk all joins to ensure no weather Add additional silicon to the area that is to...
Page 12
TWIN FAN Fitting Flashing to unit mounted on Top Hats Ridge Flashing Picture of ridge side flashing fitted. Run a silicone join across ridge side flashing Silicone between joins and Tek screw from prior to fitting back flashing centre Screw back flashing from centre out for neat finish.
TWIN FAN Fitting Sump and Motor Fan Assembly Sump must be pressed down firmly onto the dropper. The dropper must make contact with the four corners of the sump. Screw location Fix the sump to the dropper with a minimum of 4 screws.
Page 14
TWIN FAN Fitting Sump and Fan Motor Assembly continued SECURING THE MOTOR ANCHOR TO IBASE OF MOTOR & ANCHOR clip THE SUMP AND DROPPER The motor anchor cable is fitted to the base of the motor and attached to the motor lead .
TWIN FAN Unit Assembly Fitting Corner Posts Mount the four corner posts onto the sump with the notched end facing up. Fit the two center posts. Fitting stainless steel bolts Tighten bolts FINGER TIGHT ONLY. This will allow the corner posts and center posts some tolerance to set into their re- Polymer quired positions.
Page 16
TWIN FAN Unit Assembly Capping Filter Pad Slide the six filter media pads into the corner and centre posts. Seat the pads firmly into the pad retainers located in the base and make sure that the capped edge is to the outside of the unit. Water Distribution Notch Water Distributor...
Page 17
TWIN FAN Fitting Lid Support Brace Fit the Lid Support Brace into the Centre Posts NOTE: The Support Brace is to be pushed against the inside edge of the centre post, see below picture...
Page 18
TWIN FAN Unit Assembly Fitting Louvres Fit the 6 louvres. Push the louvre firmly to fit into the sump. Note that the lid support brace is fitted. Fitting the lid Secure the lid with the polymer bolts. Make sure that the shoulder of the lid bolts are seated fully through the hole in the lid and bottom out on the corner post.
TWIN FAN Plumbing Water connection Important: The system has been designed for water Flush mains supply before connecting. pressure between 100 KPA and 750 KPA. Do not use a non return type Install a pressure reduction valve if the isolator tap. water pressure is greater than 750 KPA.
Page 20
TWIN FAN Plumbing Drain Valve Installation The water level notch in the sump is On completion of installation, check that directly behind the pump tee piece the mains and pump return pipe are not kinked. Ensure that the drain support arm is located in the dimple in the sump.
TWIN FAN Electrical The 220 volt / 240 Volt connection is to be undertaken by a licensed electrical contractor. Install in accordance with AS/NZS Wall controllers 3000 : 2007 Wiring Rules. All controllers are low voltage and each unit is supplied with a 15m control cable. In The electrical connection must comply order to reduce electrical interference, with local regulations.
Page 22
TWIN FAN Electrical Fitting Keypad Cable Keypad cable exiting unit Fit mains leads and 7 core keypad cable. These cables must be physically sepa- rated. This is necessary to avoid spike voltage being induced into the low volt- age keypad cable. Hole plugs are fitted on the mains leads These plugs are to protect the cables as and the keypad cable .
Page 23
TWIN FAN Electrical Filter fitted in compliance with radiated emissions requirements for Europe Market Cables from Filter fitted to lid of electri- Cable to Motor Active Terminal cal enclosure Cable to Motor active lead Cable to Motor active lead...
TWIN FAN Connecting Multiple Twin Fan Units ATTENTION MAIN ELECTRICAL BOX ELECTRICIAN CONNECTING MULTIPLE TWIN FAN Each Twin Fan unit has a Cascade 06/1 board UNITS TOGETHER IN A STRING fitted into the base of the main electrical box which links the main and secondary electrical USING AN MRU CASCADE 06/1 boxes.
Page 25
TWIN FAN Connecting Multiple Twin Fan Units Electrical box with Cascade 06/1 board fitted into the base using double sid- ed tape 200mm cable TWIN FAN AIR CONDITIONING STRING OF 3 UNITS TWIN FAN UNIT 1 Local Cascade 06/1 MRU 2 Previous Board Next...
TWIN FAN Commissioning Streaking pads at installation Thoroughly clean all filter media debris from the base. Check that no frag- The filter media pads may have dry ments are lodged under the drain valve streaks during the first week of opera- seal.