1. Safety Instructions
• The device is not recommended to be placed on low thermal conductive surface.
For example, plastics.
• For safety reasons, please ensure the mounted device is kept for Open Frame Type ≥ 8mm,
for Case Type ≥ 4mm safety distance at all sides from other components and equipments
(Refer to Fig. 2.:). Please insert an insulation sheet between the system and product, if the safety
distance is < 4mm.
• Note that the enclosure of the device can become very hot depending on the ambient
temperature and load of the power supply.
• Do not touch the device while it is in operation or immediately after power is turned OFF.
Risk of burning!
• Do not touch the terminals while power is being supplied. Risk of electric shock.
• Prevent any foreign metal, particles or conductors from entering the device through the
openings during installation. It may cause: - Electric shock; Safety Hazard; Fire; Product failure.
• Warning: The power supply must be mounted by metal screws onto a grounded metal surface.
It is highly recommended that the Earth terminal on the connector be connected to the grounded
metal surface.
For Open Frame type of installation, ensure the power supply's Protective Earthing
(Marked "PE" in Fig. 1) point is connected to the system's Protective Earthing (PE). It is
also recommended that the input FG (Fig. 1 location 1) be connected to the system's PE.
2. Device Descriptions (Refer to Fig. 1.:)
➀ Input terminal block connector
➁ Output terminal block connector (V-)
➂ Output terminal block connector (V+)
➃ Remote ON/OFF function connector (Option)
➄ DC voltage adjustment potentiometer
3. Installation of the Device (Refer to Fig. 1.:)
Ⓐ Mounting holes for the Enclosed type of power supply (device). The device shall be mounted on
minimum of 3 mounting holes using M4 screw of minimum 4mm length. Recommended mounting
torque for tightening: 8~10Kgf.cm. For the other mounting holes without screw threads,
please use suitable screw and nut.
Mounting holes for the Open Frame type of power supply (device). The device shall be
mounted on minimum of 4 mounting holes using #6-32 screw of minimum 4mm length.
Recommended mounting torque for tightening: 6~8Kgf.cm.
Ⓑ This surface belongs to customer's end system or panel where the device is mounted.
• Use flexible cable (stranded or solid) of AWG No. 22-18. Please refer the table below for the
recommended housing and terminal of Harness connector.
• For the Remote ON/OFF function, use flexible cable (stranded or solid) of AWG No. 28-22.
Connector (Board Mounting)
Input (JST)
B3P5-VH(LF)(SN)
Output (JST)(V-)
B7P-VH(LF)(SN)
Output (JST)(V+)
B6P-VH(LF)(SN)
Remote ON/OFF
B2B-XH-A(LF)(SN)
Function (Option)
REV.01
All manuals and user guides at all-guides.com
Housing
Terminal
VHR-5N
VHR-7N
SVH-21T-P1.1
VHR-6N
XHP-2
SXH-001-P0.6
PJB-24V240WC☐A: Enclosed (cover and chassis)
4-M4 MOUNTING HOLES
4-M4 MOUNTING HOLES
A
B
2
1
FG
N
3
L
5
4
4-M4 MOUNTING HOLES
4-M4 MOUNTING HOLES
A
B
PJB-24V240WL☐A: L Frame (without cover)
4-M4 MOUNTING HOLES
4-M4 MOUNTING HOLES
A
B
2
FG
V (-)
1
3
N
L
V (+)
4
5
PJB-24V240WB☐A: Open Frame
Ø3.7 [0.15]
(MOUNTING HOLE)
3-Ø3.5 [0.14]
(MOUNTING HOLE)
A
B
2
FG
V (-)
1
N
L
3
V (+)
VR
5
4
PE: MUST CONNECT WITH SYSTEM PROTECTIVE EARTHING.
Fig. 1. Device Descriptions
D1
TOP SIDE
CN1
D1
Fig. 2. Assembly Reference
PJB-24V240W☐☐☐
PJB-24V240WC☐J: Enclosed (cover and chassis)
4-M4 MOUNTING HOLES
4-M4 MOUNTING HOLES
A
B
1
FG
2
N
L
V (-)
3
V (+)
5
4
4-M4 MOUNTING HOLES
A
4-M4 MOUNTING HOLES
B
PJB-24V240WL☐J: L Frame (without cover)
4-M4 MOUNTING HOLES
4-M4 MOUNTING HOLES
A
B
FG
1
2
N
L
V (-)
3
V (+)
4
5
PJB-24V240WB☐J: Open Frame
Ø3.7 [0.15]
(MOUNTING HOLE)
3-Ø3.5 [0.14]
(MOUNTING HOLE)
A
B
2
FG
1
N
L
V (-)
3
V (+)
5
4
PE: MUST CONNECT WITH SYSTEM PROTECTIVE EARTHING.
FRONT SIDE
CN1
If place metal plate on the bottom of PCB,
please connect to PE.
For Open Frame: D1 = 8 mm, D2 = 8 mm
For L Frame / Enclosed: D1 = 4 mm
www.DeltaPSU.com

Advertisement

loading

Summary of Contents for Delta Electronics PJB-24V240WC Series

  • Page 1 All manuals and user guides at all-guides.com Instruction Manual PJB-24V240W☐☐☐ 1. Safety Instructions PJB-24V240WC☐A: Enclosed (cover and chassis) PJB-24V240WC☐J: Enclosed (cover and chassis) • The device is not recommended to be placed on low thermal conductive surface. 4-M4 MOUNTING HOLES 4-M4 MOUNTING HOLES 4-M4 MOUNTING HOLES 4-M4 MOUNTING HOLES...
  • Page 2 All manuals and user guides at all-guides.com PJB-24V240W☐☐☐ 使用说明书 使用说明书 使用說明書 使用說明書 1. 安全规范 安全规范 1. 1. 安全上の注意 安全上の注意 • 本产品不适合摆放在低热导体,例如:塑胶。 • 熱伝導性が低い材質(例: プラスチック)に設置することはおやめください。 基于安全考虑,周围的元器件和设备必须与开架型产品保持至少 8mm的距离, L 型框架及封闭 • • 安全確保できますよう、オープンフレーム式電源をお選びになる場合、電源の周りに他の部品 や装置から必ず 8mm 以上の距離を確保して下さい。 また、Lシャーシ及びカバータイプ電源を 式产品保持至少4mm。当距离无法达到时,请于系统与本产品之间加装绝缘片。 • 受环境温度及产品负载的影响,本电源外壳温度会很高,因此在上电时和切断电源后短时间内 お選びになる場合、4mm 以上の距離を確保して下さい。どうしても距離を確保できない場合、 不要触摸电源,以免烫伤。...