LED UFO HIGH BAY
Сoverage area for ceiling mounting:
Height: 3 m
Height: 6 m
Sensitivity: 100 %/75 %/50 %/25 %
Sensitivity: 100 %/75 %/50 %/25 %
Normal moving (speed 1 m/s)
Normal moving (speed 1 m/s)
Height: 3 m
Height: 6 m
Sensitivity: 100 %/75 %/50 %/25 %
Sensitivity: 100 %/75 %/50 %/25 %
Normal moving (speed 0.3 m/s)
Normal moving (speed 0.3 m/s)
* Only 100 %/75 %/50 % detection sensitivity is workable when installed at 10 m & 15 m mounting height 25 % sensitivity is not able to detect motion signal.

REMOTE CONTROL

UHB-RC-MSK1
Button
ON/OFF
Reset
Sensor motion
Dim test
Override DH
DIM +
DIM -
DH Mode
Escena opcion
QS1
QS2
QS3
Test 2 s
HS
LS
Daylight sensor
Standby period
Hold time
Remote control and code setting conversion:
1. DIP switch settings convert to remote control: Press any button except "Reset" on the
remote control, and the sensor settings convert to the function currently selected by the
remote control. (No function button settings invalid).
2. Remote control convert to DIP switch settings:
a. Press the "Reset" button on the remote control, and all settings return to the DIP switch
settings of the sensor.
b. Turn off the power, toggle any DIP switch, connect to the power, and all settings return to
the DIP switch settings when power is supplied again.
To manually set your fixture use the top set of buttons on your wireless remote control.
There are 5 sets of parameters to set.
Detection area – sensitivity of motion sensor in percent.
Hold time – time the fixture will remain at full brightness after no motion is detected.
Stand by time – time fixture will remain on at a reduced brightness.
Stand by dim level – light output level after hold time expires and stand by time starts.
Daylight threshold – fixture can be set to adjust light output based on ambient light levels
in the area.
ASD LIGHTING CORP
E-mail: orders@asd-lighting.com
Height: 9 m
Sensitivity: 100 %/75 %/50 %/25 %
Normal moving (speed 1 m/s)
Height: 9 m
Sensitivity: 100 %/75 %/50 %/25 %
Normal moving (speed 0.3 m/s)
sold separately:
Remarks
Press the "ON/OFF" button: the fixture will switch to the constant on/off mode. Use ON/OFF button to on and off the fixture. Press any another button to switch back to the motion sensor mode.
Press "Reset" button: all parameters are the same as the DIP switch or factory settings.
Press "Sensor motion" button, the light quits from the constant on/off mode,and the sensor starts to work (The latest setting stays in validity).
Press "Dim test" button: the 0-10 V dimming works to test whether the 0-10 V dc dimming ports are connected properly. After 2 s, it returns to the latest setting automatically.
Hold for 3 s: daylight priority mode will be switched to daylight threshold mode with the preset daylight value.
Set occupany light level in range of 50 %-100 %. Dim level changes by 2 % each time Dim +/Dim - is pressed.
Hold for 3 s: sensor will be switched to daylight priority mode, if the preset daylight value is set to "Disable" the sensor will stay in daylight threshold mode.
Detection area
Hold time
Standby period
100 %
5 min
10 min
100 %
10 min
30 min
100 %
20 min
30 min
Press the "Test 2 s" button at any time to enter test mode. In this mode the sensor parameters are as follows: Detection area is 100 %, Hold time is 5 s, Standby dim level is
10 %, Standby period is 0 s, daylight sensor is disabled. This function is only for testing. Press "Reset" or any other function button to exit this mode.
Press the "HS" button for high sensitivity in the detection area. Press the "LS" button for low sensitivity in the detection area. The adjustment is based on the "Detection area" parameter you set.
Set up daylight threshold: 5 Lx (0.5 Fc)/15 Lx (1.4 Fc)/30 Lx
(2.8 Fc)/50 Lx (4.7 Fc)/100 Lx (9.3 Fc)/150 Lx (14 Fc)/Disable
Set up standby time:
0 s/10 s/1 min/3 min/5 min/10 min/30 min/+ ∞
Set up hold-time:
5 s/30 s/1 min/3 min/5 min/10 min/20 min/30 min
Web site: www.asd-lighting.com
Height: 12 m
Height: 15 m
Sensitivity: 100 %/75 %
Sensitivity: 100 %/75 %/50 %
Normal moving (speed 1 m/s)
Normal moving (speed 1 m/s)
Height: 12 m
Height: 15 m
Sensitivity: 100 %/75 %/50 %
Sensitivity: 100 %/75 %
Normal moving (speed 0.3 m/s)
Normal moving (speed 0.3 m/s)
Standby dim level
Daylight sensor
10 %
30 Lx (2.8 Fc)
10 %
Disable
10 %
Disable
Standby dim level
Set up standby dim level: 10 %/20 %/30 %/50 %
Detection area
Set up detection area: 25 %/50 %/75 %/100 %
Remote distance
Toggle the button to set the remote distance of remote control and sensor.
9.8ft (3m) Max
32.8ft
(10m)
16.4ft
(5m)
16.4ft (5m) Level
32.8ft (10m) Level
For most up-to-date spec sheets please refer to asd-lighting.com
English
Сoverage area for wall mounting:
Height: 2 m
Sensitivity: 100 %/75 %/50 %/25 %
Normal moving (speed 1 m/s)
Height: 2 m
Sensitivity: 100 %/75 %/50 %/25 %
Slow moving (speed 0.3 m/s)
Induction model
Note: Detection area / Hold-time /Standby
period /Standby dim level/Daylight
HS
sensor can be adjusted by pressing the
HS
corresponding button. The latest setting
will stay valid
HS
16.4ft (5m) Max
13.1ft (4m) Max
49.2ft
(15m)
49.2ft (15m) Level