Page 3
[RH8 RO MEMBRANE HOUSING INSTRUCTION MANUAL] Notice 1. Please install and test the housing according to the product operation manual. 2. This product is designed for filter equipment which is used for water filtration only, please don’t use it on other purpose to avoid danger.
Page 4
[RH8 RO MEMBRANE HOUSING INSTRUCTION MANUAL] 11. Please avoid rapid switching of ball valve and continuous countercurrent which may cause damage of filter while using the product. 12. Be sure to release the pressure inside the filter housing completely before replacing filter cartridges.
Page 6
[RH8 RO MEMBRANE HOUSING INSTRUCTION MANUAL] Instruction Manual 1. Open the filter and install the internal parts:. Install ②RO Head and ③⑤O-ring. Unfasten ①Clamp. Connect ②RO Head with the top of ④PVC and the bottom of ④ PVC with inside membrance. Fasten the ①Clamp tightly. (If the connect point of membrance is hollow, please connect the ④PVE Coupling with ②RO Head first.)
Page 7
[RH8 RO MEMBRANE HOUSING INSTRUCTION MANUAL] c. Check if there is any leakage. (It is suggested install a pressure gauge to check the pressure during the test. Pouring water into the housing until the pressure reaches the standard of the shell design pressure.
Need help?
Do you have a question about the RH8 and is the answer not in the manual?
Questions and answers