Thank you for purchasing the VTC eLock. The information
contained in these instructions is intended to serve as a
guide so as to allow the eLock to be quickly and easily
put into service. 300 Series eLock can be configured to
work in conjunction with existing 802.11g or Ethernet
networks.
Network VTC eLock has three components:
Controller
Exterior mount
VTC eLock controller
1.
Dot matrix LCD
2.
Network button (blue LED)
3.
"UP" button
4.
"NEXT/SELECT" button
5.
"BACK/CANCEL" button
6.
"MENU" button
7.
"DOWN" button
8.
+ Button
9.
- Button
10. Low battery indicator
(yellow LED)
11. Magstripe reader location
(if equipped)
12. HID Prox or HID iCLASS
reader location (if
equipped)
13. "ENTER" button
14. "CLEAR" button
15. Alpha-numeric keypad
200/300 Series — VTC eLock Instructions
– VTC eLock Instructions
Motorized gear-driven latch
1
2
3
4
5
6
7
8
VTC
For complete set up and installation instructions for
networked and stand-alone eLocks, please see the
"Help" section in LockView NTC/VTC Software v4.
Control module / battery compartment
Interior mount
9
10
15
14
13
12
11
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Level 5 VTC eLock 200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Snap-On Level 5 VTC eLock 200 Series

  • Page 1 200/300 Series – VTC eLock Instructions Thank you for purchasing the VTC eLock. The information For complete set up and installation instructions for contained in these instructions is intended to serve as a networked and stand-alone eLocks, please see the guide so as to allow the eLock to be quickly and easily “Help”...
  • Page 2 200/300 Series VTC eLock — Components Front view: eLock controller Integrated Wi-Fi antenna cable 9V Battery USB Port for direct connection included for 300 Jumper Port to LockView software Series Wi-Fi version Back view: VTC eLock controller Battery cable connector 200/300 Series VTC eLock Components 200/300 Series —...
  • Page 3 200/300 Series VTC eLock — Components continued Control module / battery compartment Door switch connector (door 2.5 mm AC adapter plug-in Latch connector (Latch 1; one switch not included) (adapter not included) latch is included) Wi-Fi antenna cable connector Ground terminal Battery pack cover (6-AA batteries or Ethernet connector (Wi-Fi not included)
  • Page 4: Unit Features

    200/300 Series VTC eLock — Instructions Unit Features: Warning: install the batteries as shown in the battery compartment. Polarity (+) or (-) must be correct. Replace w Choose 802.11g or Ethernet Networked configurations that batteries as a set. Always use new batteries when replacing uses the facilities existing infrastructure for actual 2-way the old set.
  • Page 5 200/300 Series VTC eLock — Instructions continued 9. CREDENTIAL NAME ENTRY will appear. Press 2 - 9 for A - Z; To place an eLock into Passage Mode: press 1 for , + or ; press 0 for “space”; press and hold PIN CREDENTIAL 0 - 9 for numbers.
  • Page 6 200/300 Series VTC eLock — Instructions continued iCLASS or Magstripe credentials). EXITING PASSAGE MODE 5. The below will appear. Type in the name of the lock. will flash on the LCD and the latch bolt will extend. Methods to begin building a database of eLocks in LockView Software Note: Supervisor, User and parameter changes that already...
  • Page 7 200/300 Series VTC eLock — Manual Programming Credential Menu 6. Press ‘UP” / “DOWN” to scroll by line or +/- to scroll by page to highlight credential to be deleted and press “NEXT/ ADD CREDENTIAL SELECT. ” Note: There are two status levels; Supervisor and User. Each 7.
  • Page 8: Display Formats

    200/300 Series VTC eLock — Manual Programming continued 6. Press ‘UP” / “DOWN” to scroll by line or +/- to scroll by page 3. Press “DOWN” button to highlight DISPLAY FORMATS and to highlight credential to be edited. press “NEXT/SELECT. ” 7.
  • Page 9: Lcd Backlight

    200/300 Series VTC eLock — Manual Programming continued 4. LCD Contrast will be displayed. 3. Press “DOWN” button to highlight RESET NET SCHED. and press “NEXT/SELECT. ” 5. Enter 1 - 9 on numeric keypad or +/- buttons to adjust. 4.
  • Page 10: Setup Code

    200/300 Series VTC eLock — Manual Programming continued Setup Code Stand-alone & Networked eLock Alarm States **In order to ensure the security of the application on which the eLock will be installed, the setup code (supplied The eLock has programmable ALARM/ALERT STATES. on green sticker set as Setup Cd) must be kept in a safe location.** 1) Battery Low...
  • Page 11 200/300 Series VTC eLock — Manual Programming continued 4) Overdue Network Check-in Note: There is no audible alarm that can be triggered at the eLock; however, NETWORK TEST can be used to determine (A properly configured and enabled networked eLock is Wi-Fi strength and quality.
  • Page 12 Notes Part #: 332986000000 Copyright 2012 © CompX Security Products Any companies and/or products referred to herein are marks or registered trademarks of their respective companies, owners and/or mark holders.

This manual is also suitable for:

Level 5 vtc elock 300 series

Table of Contents