6. Upgrade Firmware

Upgrading from software version 4.10 or higher

6.1 Upgrade using USB Cable

1.
Connect USB cable (Item No. 110001526) to PC USB port (Remove other USB cables
connected to PC)
2.
Connect Display cable to USB cable
3.
In the menu go to, Setup->"password"->Communication-> Firmware upgrade by cable-
>Confirm Firmware upgrade and press "OK"
4.
Display should now be looking like this:
Upgrade Ready
Power Cycle and
Start PC App.
5.
Disconnect display from usb cable and connect it again (Power cycle)
6.
Make sure the Green "ON" led and the red "OFF" led at the display is both on, display is
blank
7.
Startup PC program FWU200.exe (can be downloaded from Nilfisk Food website)
8.
Window should be looking like this
9.
Press "Browse" button
10.
Select the file you will use for upgrade. Software File can be downloaded from Nilfisk Food
website. The name of the file should end with ".hex". Ex V4.14_SB_DISP.hex
11.
When the file is located press "Open" in browser window
12.
The file name will now be written in file text line