Table of Contents

Advertisement

Quick Links

Cod. 161601EN
2016-12-28 Rev.B
KERATRON
NOVA
Videokeratoscope
REF. 161601
MANUAL FOR INSTALLATION AND USE
OPTIKON 2000 SpA
Via del Casale di Settebagni, 13 - 00138 Roma
Telefono +39 06 8888410 - Fax +39 06 8888440
e-mail
sales@optikon.com
-
www.optikon.com

Advertisement

Table of Contents
loading

Summary of Contents for OPTIKON Keratron Nova

  • Page 1 Cod. 161601EN 2016-12-28 Rev.B ™ KERATRON NOVA Videokeratoscope REF. 161601 MANUAL FOR INSTALLATION AND USE OPTIKON 2000 SpA Via del Casale di Settebagni, 13 - 00138 Roma Telefono +39 06 8888410 - Fax +39 06 8888440 e-mail sales@optikon.com www.optikon.com...
  • Page 2 Optikon 2000 SpA is a company certified ISO 9001 and ISO 13485 which produces surgical and diagnostic devices for ophthalmology. All Optikon 2000 products are manufactured in accordance with the requirements of Directive 93/42 / EEC on medical devices.
  • Page 3: Table Of Contents

    Mechanical precautions ............3-5 SYMBOLS ..............4-1 GENERAL INFORMATION ..........5-1 System Description ............... 5-1 5.1.1 The topography in the Keratron NOVA ........5-2 5.1.2 The cone bivalent mire and Topography ........5-2 5.1.3 Main characteristics............5-4 Technical specification ............5-5 Electromagnetic Compatibility Tables .........
  • Page 4 7.3.2 PUPILLOMETRY ..............7-20 DATABASE .................7-20 7.4.1 IMPORT SOFTWARE ON SCOUT ..........7-25 SHUTTING DOWN ..............7-26 GUIDE TO TROUBLESHOOTING ........8-1 Troubleshooting ..............8-1 KERATRON SCOUT™ SOFTWARE ON PC EXTERNAL ....9-1 Introduction ................ 9-1 ® Keratron Scout software download from the Web ......9-1 ®...
  • Page 5: Preliminary Statements

    1 PRELIMINARY STATEMENTS OPTIKON 2000 SpA requires the user of this system to carefully read the specific information in this manual. It is the operator's duty to ensure the staff has a thorough understanding of the operation of the instrument before use. In no event OPTIKON 2000 SpA is responsible with respect to any injury, incidental or consequential damages caused to the buyer, to operators or patients following use of the product.
  • Page 6 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK...
  • Page 7: Limited Warranty Conditions

    OPTIKON SpA authorised technical service. OPTIKON 2000 SpA reserves the right to verify, in case of failure, if the instrument and / or its accessories have been altered or tampered with in any way, or have been damaged by improper use.
  • Page 8 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK...
  • Page 9: Warnings

    Reorient or relocate the other devices. Increase the distance between the devices themselves. Connect the unit to a different power outlet other than that to which other devices are connected. Consult your dealer or authorized Optikon 2000 SpA technical service. Cod. 161601EN 2016-12-28 Rev.B...
  • Page 10 Keratron™ Nova Manual for installation and use OPTIKON 2000 • Keratron™ Nova has been developed and optimized for the human eye measurement. The use and evaluation of Keratron™ Nova in conditions not specified in this manual, or performed using surfaces that have a reflectivity or...
  • Page 11: Environmental Precautions

    Keratron™ Nova Manual for installation and use OPTIKON 2000 • The device contains a patient database and thus sensitive data. In the case in which such device is not in a protected area and therefore accessible to the authorized personnel only, access should be protected by a password as shown in 7.2.3.
  • Page 12 Keratron™ Nova Manual for installation and use OPTIKON 2000 The Keratron™ Nova, when mounted on a LAF, constitutes an electro medical system. It is responsibility of the organization installing the system (in general the hospital) or operator, to verify the whole system compliance with the IEC 60601-1.
  • Page 13: Mechanical Precautions

    Keratron™ Nova forward. • Do not touch any of the optical surfaces. Cleaning or maintenance should be performed by Optikon 2000 SpA authorized personnel . • If the device suffers mechanical damage as a result of a collision or fall, dangerous electrical parts may be uncovered;...
  • Page 14 Keratron™ Nova Manual for installation and use OPTIKON 2000 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK Cod. 161601EN 2016-12-28 Rev.B...
  • Page 15: Symbols

    Keratron™ Nova Manual for installation and use OPTIKON 2000 4 SYMBOLS The table below shows the symbols used on Keratron™ Nova, and their meanings. SYMBOLS AFFIXED ON THE UNIT SYMBOL DESCRIPTION ALTERNATING CURRENT DIRECT CURRENT OFF (POWER) ON (POWER) APPLIANCE OF CLASS II...
  • Page 16 Keratron™ Nova Manual for installation and use OPTIKON 2000 SYMBOL DESCRIPTION MANUFACTURER AND DATE OF MANUFACTURE IDENTIFICATION CODE SERIAL NUMBER RECYCLING OF ELECTRICAL AND ELECTRONIC EQUIPMENT OPERATING INSTRUCTIONS POLARITY OF THE POWER CONNECTOR IN DIRECT CURRENT LAN (CONNECTOR) PEDAL (CONNECTOR) USB (CONNECTOR) Cod.
  • Page 17: General Information

    Keratron™ Nova Manual for installation and use OPTIKON 2000 5 GENERAL INFORMATION 5.1 SYSTEM DESCRIPTION Figure 5-1: Keratron™ Nova Cod. 161601EN 2016-12-28 Rev.B...
  • Page 18: The Topography In The Keratron Nova

    The device is designed to be fixed on the tonometer hole of the slit lamps most used in the world or to the base with joystick (not supplied) of the Optikon (ref. 163202 and following).
  • Page 19 Nova unit uses an evolved version of the EPCS (Eye Position Control System) electronic circuit as in the other topographer products from Optikon 2000 SpA The apex of the eye is intercepted by the photocells when it is located within a range around the predetermined distance from the optical head.
  • Page 20: Main Characteristics

    Keratron™ Nova Manual for installation and use OPTIKON 2000 The cone is backlit by a two wavelength LED matrix: the yellow-amber (λ = 590nm) to capture the topographical images and the infrared (λ = 940nm), for the tracking of the pupillary edge in scotopic conditions. Behind this matrix are the fixation LED, focused at a great distance focus, and a camera.
  • Page 21: Technical Specification

    Keratron™ Nova Manual for installation and use OPTIKON 2000 5.2 TECHNICAL SPECIFICATION PARAMETER SPECIFICATION Manufacturer: ......OPTIKON 2000 SpA Via del Casale di Settebagni, 13 00138 Rome - Italy Model: ......... Keratron™ Nova Reference: ........161601 Regulatory compliance: ..... Medical Device Directive 93/42/EEC Technical standards: ....
  • Page 22 Keratron™ Nova Manual for installation and use OPTIKON 2000 Footswitch Degree of protection against entry of liquids: ....... IPX1 DIMENSIONS ........... Height:285 mm Width: ......... 155 mm Depth: ......... 270 mm Weight ........:1.8 Kg INTERFACES LAN ..........Ethernet 10/100 USB ..........
  • Page 23: Electromagnetic Compatibility Tables

    Keratron™ Nova Manual for installation and use OPTIKON 2000 5.3 ELECTROMAGNETIC COMPATIBILITY TABLES 5.3.1 GUIDE MANUFACTURER’S STATEMENT-ELECTROMAGNETIC EMISSIONS The Keratron™ Nova product is designed to work in the electromagnetic environment specified below. The customer or user of Keratron™ Nova must guarantee that it is used only in such an environment.
  • Page 24: Guide And Manufacturer's Statement-Electromagnetic Emissions

    Keratron™ Nova Manual for installation and use OPTIKON 2000 5.3.2 GUIDE AND MANUFACTURER’S STATEMENT - ELECTROMAGNETIC IMMUNITY The Keratron™ product is designed to work in the electromagnetic environment specified below. The customer or user of the Keratron™ Nova must guarantee that it is used only in such an environment.
  • Page 25 Keratron™ Nova Manual for installation and use OPTIKON 2000 NOTES: is the ac mains voltage prior to application of the test level Note 1: At 80 MHz and 800 MHz, the highest frequency is applied. Note 2: These guidelines may not be applicable in all situations. The electromagnetic propagation is influenced by the absorption and reflection of structures, objects and persons.
  • Page 26: Recommended Distance Of Separation Between Portable And Mobile

    Keratron™ Nova Manual for installation and use OPTIKON 2000 5.3.3 RECOMMENDED DISTANCE OF SEPARATION BETWEEN PORTABLE ® AND MOBILE RADIO COMMUNICATION DEVICES AND THE KERATRON NOVA DEVICE The Keratron™ Nova is intended for use in an electromagnetic environment in which radiated RF disturbances are under control.
  • Page 27: Light Emission

    5.5 CIRCUIT DIAGRAMS Upon request, OPTIKON 2000 SpA provides wiring diagrams, parts lists, descriptions, calibration instructions or other information to support the operator’s qualified personnel in case of repair of the serviceable elements of the unit.
  • Page 28: Standard Configuration

    5.7 SOFTWARE DESIGNER Both the Keratron™ Nova software inside the unit and the Keratron™ Scout software inside the PC communicating with the unit, are produced by Optikon 2000 SpA For issues related to updates, error reporting and corrections, see Optikon 2000 SpA.
  • Page 29: Accessories Not Supplied

    TRADEMARKS: Windows XP, Windows Vista, Windows 7, Windows 8 and Windows 10 are registered trademarks of Microsoft Corporation Access is a registered trademark of Microsoft Corporation Keratron is a registered trademark of Optikon 2000 SpA Cod. 161601EN 5-13 2016-12-28 Rev.B...
  • Page 30 Keratron™ Nova Manual for installation and use OPTIKON 2000 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK Cod. 161601EN 5-14 2016-12-28 Rev.B...
  • Page 31: Installation

    If the package or its contents are damaged, notify the carrier and Optikon 2000 SpA as soon as possible. Make sure that the content is as specified in the accompanying shipping documents. In case of in congruity, inform Optikon 2000 SpA immediately.
  • Page 32: Installation Procedure

    Set the main switch of the device to "0" (off). Connect the supplied cable to the power supply. For safety, use either the cable supplied by Optikon or a cable complying to the safety standards. Only use a XP Power AFM30US12C2 power supply specifically provided by Optikon (Ref.
  • Page 33 Keratron™ Nova Manual for installation and use OPTIKON 2000 Insert the pin of the hand wheel fully to mount on a slit lamp in the hole for accessories of the same LAF (or movable base) and turn the knob in the direction indicated by "TIGHT"...
  • Page 34 Keratron™ Nova Manual for installation and use OPTIKON 2000 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK Cod. 161601EN 2016-12-28 Rev.B...
  • Page 35: Use Of The Keratron™ Nova - Home Screen

    Keratron™ Nova Manual for installation and use OPTIKON 2000 7 USE OF THE KERATRON™ NOVA - HOME SCREEN NOTE: This manual describes controls and messages in the default state, i.e. in English [English] language. The location and meaning of the messages and controls does not change with the selected language.
  • Page 36: Topography Calibration [Calibration]

    Keratron™ Nova Manual for installation and use OPTIKON 2000 7.1 TOPOGRAPHY CALIBRATION [CALIBRATION] Selecting [Calibration] on the touch-screen the operator is introduced into the section dedicated for the calibration of the topography instrument. For this operation the calibration sphere, supplied is needed.
  • Page 37 Keratron™ Nova Manual for installation and use OPTIKON 2000 Figure 7-3: Photocell calibration (Near) The acquisition procedure for calibration is as shown in figure 7-3; the screen displays the live image of the camera with the relative position of the photoelectric cells with respect to the corneal apex.
  • Page 38 Keratron™ Nova Manual for installation and use OPTIKON 2000 Figure 7-4: Checking the cleanliness of the calibration sphere If the operator confirms cleaning by pressing [Yes], the software draws the 28 mires and the screen looks like figure 7-5, here the operator must make sure the reconstruction of the rings, to the edge of the mires, is complete and without “skipping".
  • Page 39 Keratron™ Nova Manual for installation and use OPTIKON 2000 The procedure carried out for the "Near" photocells must be repeated in the same way for the "Far" photocells of the bivalent cone. The sequence of calibrations is considered successfully completed if the message figure 7-6 appears.
  • Page 40: Settings [Settings]

    (Nova.exe and Nova.dll). The same information is legible for the firmware resident in the electronics of the instrument. The software designers of all these applications is Optikon 2000 SpA to which you can refer for any question. Figure 7-7: Information of the About screen Cod.
  • Page 41: General

    Keratron™ Nova Manual for installation and use OPTIKON 2000 7.2.2 GENERAL In the General folder (figure 7-8) the system speaker volume can be changed by choosing mute, low or high sound and the intensity of the display backlight (if allowed by the model installed) can be modified as well.
  • Page 42 Figure 7-10: Changing date and time The [Service] option in figure 7-11 is planned for use under the supervision of the Optikon 2000 SpA staff or authorized by it for updates or checking of the internal features of the machine.
  • Page 43: Database

    Keratron™ Nova Manual for installation and use OPTIKON 2000 Figure 7-11: Enter the service password This option is in any case protected by a password to avoid accidental inputs. Any entry attempt in this section violates the terms of the guarantee.
  • Page 44 Keratron™ Nova Manual for installation and use OPTIKON 2000 You can choose how many items per page to display and also which columns to display and their width. Furthermore, it is also possible to protect the database from unauthorized access by entering a 4-digit numeric password (default “0000”).
  • Page 45: Network

    Keratron™ Nova Manual for installation and use OPTIKON 2000 7.2.4 NETWORK In the tab Network (figure 7-13) are collected the configurations necessary for the direct Ethernet connection to an external PC (Remote IP host; Remote port), using a "crossed" cable and one for a possible connection through the local network (Remote Computer Name, Local TCP / IP Settings).
  • Page 46: Process/Print

    Keratron™ Nova Manual for installation and use OPTIKON 2000 7.2.5 PROCESS/PRINT In PROCESS / PRINT you can choose a network printer which may be connected to the device and the print mode of topographies (text or graphics). 7.2.6 LOCALIZATION The section Localization (figure 7-14) you can set the software language for the Keratron™...
  • Page 47: Corneal Topography [Topography]

    Keratron™ Nova Manual for installation and use OPTIKON 2000 7.3 CORNEAL TOPOGRAPHY [TOPOGRAPHY] Pressing [Topography] on the home screen, if the machine was not previously calibrated (see "Calibration" §7.1) the following message appears: Figure 7-15: Warning due to the absence of calibration files Figure 7-16: Patient data otherwise the window for patient data input is displayed.
  • Page 48 Keratron™ Nova Manual for installation and use OPTIKON 2000 By clicking on the name, the screen for entering the data is displayed. Figure 7-17: Data input An auto-completion function, will show the surnames and names of the patients already present in the unit’s database.
  • Page 49 Keratron™ Nova Manual for installation and use OPTIKON 2000 Once completed data input the following acquisition window is shown. Figure 7-19: Capture window It is possible to switch between the "Near" and "Far” sensors by clicking on the [Sensor] icon; see §5.1.2 for details on both the standard and bivalent cones.
  • Page 50 Keratron™ Nova Manual for installation and use OPTIKON 2000 Figure 7-20: Topography Live (New style and old-fashioned) You can also choose which eye is under investigation, clicking on [OD] or [OS] (right eye or left eye) during the live acquisition phase; this information is shown in the lower left of the image, in red colour (OD) and blue (OS).
  • Page 51 Keratron™ Nova Manual for installation and use OPTIKON 2000 indicate in red, too near or far from the focus area, in a yellow the approximate correct position and green for the "OK" position. These indications are accompanied by distinctive acoustic signals that allow you to focus better on the eye positioning rather than on the light indicators.
  • Page 52 Keratron™ Nova Manual for installation and use OPTIKON 2000 Figure 7-22: Preview By pressing the circular button you can see beyond the normal acquisition, the reconstruction of the rings, the map of the curvatures and the axial map. The image is not selected by default;...
  • Page 53: Tbut

    Keratron™ Nova Manual for installation and use OPTIKON 2000 We are reminded to use this feature when necessary; acquisition conducted in this manner may result in precision higher than the acquisition stated in this manual for normal acquisition. The diagnosis must be carried out by crossing other data and patient history.
  • Page 54: Pupillometry

    If you are using the Ethernet connection and you want to import the exam in the Scout software on an external PC, launch the program and click on the "Acquire Keratron Wave/Keratron/Keratron Nova™” icon. On the Keratron™ Nova, in the Cod. 161601EN 7-20 2016-12-28 Rev.B...
  • Page 55 Keratron™ Nova Manual for installation and use OPTIKON 2000 Database screen, select the patient and the desired exam and then click on the PC which will be enabled, just for the transfer to an external PC. Instead, clicking on the name and patient name and then selecting one of his exam and then clicking the [OK] button, you can see him on Keratron™...
  • Page 56 Keratron™ Nova Manual for installation and use OPTIKON 2000 Figure 7-26: The map of curvatures By pressing the [i] button you will be able to see the patient data (see figure 7-27), and pressing the usual button, export the exam on the USB stick (if connected).
  • Page 57 Keratron™ Nova Manual for installation and use OPTIKON 2000 Figure 7-28: Keratometric data The figure 7-28 shows, as an example, the representation of the calibration sphere with the map of the curvatures. On the left side of the screen are shown the values of power or curvature in diopters...
  • Page 58 Keratron™ Nova Manual for installation and use OPTIKON 2000 7-29: Options panel The device contains a patient database and thus sensitive data. In the case in which such device is not in a protected area and accessible to the authorized personnel only, access should be protected by a password as shown in 7.2.3.
  • Page 59: Import Software On Scout

    Keratron™ Nova Manual for installation and use OPTIKON 2000 7-30: authentication screen After 5’ of idleness within the database area, the device will display this screen: 7-31: Screen privacy policy and the software will move to the main menu any operation on the database is left suspended.
  • Page 60: Shutting Down

    Keratron™ Nova Manual for installation and use OPTIKON 2000 import the exam that will be added to the database in accordance with the patient's name and surname. 7.5 SHUTTING DOWN The Keratron™ Nova is turned off by setting the main switch to “0".
  • Page 61 Keratron™ Nova Manual for installation and use OPTIKON 2000 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK Cod. 161601EN 7-27 2016-12-28 Rev.B...
  • Page 62: Guide To Troubleshooting

    Keratron™ Nova Manual for installation and use OPTIKON 2000 8 GUIDE TO TROUBLESHOOTING 8.1 TROUBLESHOOTING This section describes the messages that identify operating situations of the Keratron™ Nova that have not been previously described in the manual. Symptom or Message...
  • Page 63 Keratron™ Nova Manual for installation and use OPTIKON 2000 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK Cod. 161601EN 2016-12-28 Rev.B...
  • Page 64: Keratron Scout™ Software On Pc External

    First, you must uninstall the previous version, then proceed with the installation of the updated version of Keratron™ Scout configuration. After registration, the latest version is available for download from the Optikon 2000 SpA website: http://www.optikon.com/. NOTE: To install the software you must have system administrator privileges (Administrator).
  • Page 65 OPTIKON 2000 IF YOU AREN’T A REGISTERED USER • Under the heading "Don’t have and Optikon Account", click on "Create one now", fill in all items and sign up. • You will be allowed at this point to proceed with the download within 24 hours after having received a confirmation e-mail from Optikon 2000.
  • Page 66: Setting Up The Direct Ethernet Connection To The External Pc

    Keratron™ Nova Manual for installation and use OPTIKON 2000 9.4 SETTING UP THE DIRECT ETHERNET CONNECTION TO THE EXTERNAL PC In order to communicate with the Keratron™ Nova, via the directly connected Ethernet LAN "crossed" cable, the network connection must be properly configured on the external PC that will be running the Keratron™...
  • Page 67 Keratron™ Nova Manual for installation and use OPTIKON 2000 figure 9-2 : Network card protocols In the new window (figure 9-3) the necessary communication parameters are set. Select "Use the following IP address" (1) and in the IP address (2), and Subnet Mask (3) fields input, respectively, the following configurations: 192.168.0.140.
  • Page 68: Setting Personal Computer In Windows Vista And Windows 7

    Keratron™ Nova Manual for installation and use OPTIKON 2000 If you intend to change this configuration you should make these changes under the supervision of a Network Administrator. 9.4.2 SETTING PERSONAL COMPUTER IN WINDOWS VISTA AND WINDOWS 7 For Vista and Windows 7 a possible configuration sequence is: →...
  • Page 69 Keratron™ Nova Manual for installation and use OPTIKON 2000 figure 9-5 : Connection status for the chosen network Pressing the Properties button (1) you can access the protocol window (figure 9-6). Inside the Network folder, select with the mouse Internet Protocol Version 4 (TCP / IPv4) (1) and then press Properties (2).
  • Page 70: Configuration Of The Keratron™ Nova

    Keratron™ Nova Manual for installation and use OPTIKON 2000 figure 9-7 : Configuring the TCP / IP protocol in Windows Vista/Windows 7 NOTE The configuration, shown in figure 9-7, is compatible with the "Factory Default" (factory settings) of Keratron™ Nova.
  • Page 71: Configuring The Connection To An External Pc Via The Local Network

    Keratron™ Nova Manual for installation and use OPTIKON 2000 figure 9-8 : Configuration window network for the Keratron™ Nova Remote Host IP (1) is meant to be the PC “IP address” which will be sharing and ™ process data throught the Keratron Scout Software.
  • Page 72: Automatic Address Configuration (Dhcp)

    Keratron™ Nova Manual for installation and use OPTIKON 2000 dynamic configuration protocol of the IP addresses (DHCP) and a network with static IP addresses. 9.5.1 AUTOMATIC ADDRESS CONFIGURATION (DHCP) If the Keratron™ Nova is placed within a network in which the addresses are dynamically changed, this mode can be enabled with the selection shown in figure 9-9.
  • Page 73: Configuration With Static Address

    OPTIKON 2000 figure 9-10 : In the DHCP it is possible to indicate the name of the computer to which the Keratron Nova is connected 9.5.2 CONFIGURATION WITH STATIC ADDRESS The network connection through a static IP address can be made in Keratron™ Nova as shown in figure 9-11.
  • Page 74 Manual for installation and use OPTIKON 2000 figure 9-11 : IP address setting of the Keratron Nova In figure 9-12 is shown as an example the configuration of the subnet mask. NOTE The configuration parameters do not have default values so the enhancement of all parameters is recommended The presence of the network flow can be verified through the Status field.
  • Page 75 It may necessary to provide this address to the network administrator to authorize the Keratron Nova connection within an existing network locate. This field is not editable by the user.
  • Page 76 Keratron™ Nova Manual for installation and use OPTIKON 2000 9.6 STRUCTURE OF THE KERATRON SCOUT SOFTWARE (ON EXTERNAL PC) Default database folder. Scout Trialsets folder (empty after the first installation). ™ Keratron Scout system file. Pay attention to this folder!! Enter here the imported printing models and new ones The software stores here the temporary files.
  • Page 77: Customization Of The Keratron Scout™ Software

    Keratron™ Nova Manual for installation and use OPTIKON 2000 9.7 CUSTOMIZATION OF THE KERATRON ™ SCOUT SOFTWARE The toolbar buttons and software operation may be customized/modified. Modify the operation of the software through the window "Options" (Options) of the "Tools" menu (Tools).
  • Page 78: Uninstalling The Keratron™ Scout Software

    Keratron™ Nova Manual for installation and use OPTIKON 2000 figure 9-14: Identification of the version of the Scout software 9.9 UNINSTALLING THE KERATRON™ SCOUT SOFTWARE We can assume two different methods: the first uses the standard Windows uninstall procedure: 1. Start "Control Panel”.
  • Page 79: Tool Tips And Screens Of The Keratron™ Scout Software

    "?" on the menu bar). 9.10.2 TRANSFER OF AN IMAGE FROM KERATRON™ NOVA Start from the acquisition menu "from Keratron/Keratron Wave/Keratron Nova" or the icon on the toolbar Scout software: "Acquire images Keratron/Wave/Nova", and wait for the Keratron™ Nova to start sending data.
  • Page 80: Troubleshooting The Keratron Scout™ Software

    Keratron™ Nova Manual for installation and use OPTIKON 2000 To choose the graphic representation, automatically created and displayed on the screen during processing (including the window Photo-Process - Processing photographs), select "Options" from the "Tools" menu and select "Processing”. From the "Default Map Type", select the desired representation and press OK.
  • Page 81: The Scout.ini File

    Keratron™ Nova Manual for installation and use OPTIKON 2000 xxx.dll not fount - impossible to find the DLL xxx.dll - etc.) " We suggest you take the following actions: • download the Scout software (v. §9.2) • proceeding with a new installation, rewriting the file when prompted.
  • Page 82: Pc Replacement

    Keratron™ Nova Manual for installation and use OPTIKON 2000 • Each operator will point to his own database via "File → Open Database" (File → Open database) or from the "File → Recent Database" (File → Recent Databases). 9.11.4 PC REPLACEMENT •...
  • Page 83: Various Problems

    The guide to the identification of the faults listed below, lists some faults that may occur during operation, its symptoms and the appropriate corrective action. If the Keratron™ Scout system still does not work even after performing the corrective actions listed below, call the authorized OPTIKON 2000 SpA service SYMPTOMS CORRECTIVE ACTION...
  • Page 84: Nova.exe Update

    Restart the Scout program and setup again the preferred options. 9.12 NOVA.EXE UPDATE To update the Keratron Nova software it must be transferred to a USB memory stick using the Keratron Scout software (if available). Insert the USB memory stick included in the PC.
  • Page 85 Keratron™ Nova Manual for installation and use OPTIKON 2000 figure 9-10: Make Keratron key Press the "Write" button figure 9-11 Once the operation is finished, insert the memory stick into the USB port of the Keratron and switch on the device.
  • Page 86 Keratron™ Nova Manual for installation and use OPTIKON 2000 figure 9-12 : Initial window for the upgrade To proceed with the upgrade, select "Update Keratron™ Nova", press "OK" and wait for the completion of the operation to launch the software. Then, remove the memory stick.
  • Page 87 Keratron™ Nova Manual for installation and use OPTIKON 2000 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK Cod. 161601EN 9-24 2016-12-28 Rev.B...
  • Page 88: Cleaning, Sterilization And Maintenance

    Keratron™ Nova Manual for installation and use OPTIKON 2000 10 CLEANING, STERILIZATION AND MAINTENANCE The medical staff has the responsibility of providing for the maintenance of the existing tools and equipment in the best operating conditions. The simple steps described below are practical guidelines to define a program of care and proper maintenance.
  • Page 89: Sterilization

    For system security, the compliance with current leakage values according to EN60601-1 standards must be tested at least once a year. Contact the Department of Bioengineering of your health facility or your local Distributor / Optikon 2000 SpA technical assistance.
  • Page 90: Backup Battery Replacement

    NOTE: To avoid the loss of fluids, in the case of prolonged instrument inactivity, contact Technical Support Optikon 2000 SpA or the staff, authorized by the latter, for the removal of the battery. NOTE: Dispose of the battery in accordance with the Environmental Warnings of §...
  • Page 91 Keratron™ Nova Manual for installation and use OPTIKON 2000 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK Cod. 161601EN 11-2 2016-12-28 Rev.B...
  • Page 92: Index

    Keratron™ Nova Manual for installation and use OPTIKON 2000 12 INDEX electrical Specifications ....5-8 EN 60601-1 ........3-5 entrance pupil ........5-6 Abort ........7-22, 7-26 environment ........3-3 acquisition of an image....7-38 environmental specifications ...5-7 anaesthetics ........3-3 EPCS ..........5-5 apex ....... 5-5, 5-6, 7-38 ethernet .......
  • Page 93 Keratron™ Nova Manual for installation and use OPTIKON 2000 ® ® ® 9-46 Windows XP/Vista / Windows 7 offset ..........7-42 OK ..........7-26 operating room ........ 3-5 Operator ........9-66 patient area ......3-4, 3-5 power ..........7-42 Power ..........7-42 precision ........
  • Page 94: Appendix

    Keratron™ Nova Manual for installation and use OPTIKON 2000 13 APPENDIX Cod. 161601EN 13-1 2016-12-28 Rev.B...

This manual is also suitable for:

161601

Table of Contents