Functions/features explanation
Adjusting the scale factor for the strong/short
(60 ml) cup volume.
13. Remove the water tank from the machine. (for
adjusting the right parameter, the internal SW
will check if the water level sensor is activated
yes/no)
14. Press the 1- and 2 cup button simultaneously
and plug the mains on.
15. Release the 1- and 2 cup button, if successful,
the on/off LED will switch on less bright/
intense as normal, indicating the scale factor
reprogramming has entered.
16. Depending if the volume has to de- or increase
you have to push the one- or two-cup button.
Every time you push the 1- or 2-cup button,
the LED will turn off for 0.5 second (feedback
to user) and the scale factor will be shortened
or lengthened depending which button was
pushed.
Pushing 1-cup button, scale factor will be
shorten approximately - 1 cc/ml (less coffee)
Pushing 2-cup button, scale factor will be
lengthen approximately + 1 cc/mL (more
coffee)
The new value will be stored when you switch
the appliance off by pushing the main switch.
(LED will turn off)
17. Turn appliance on again and brew one strong
coffee cup by pressing the 1-cup button twice,
measure the volume. In case the volume is not
within specification repeat steps 13 – 17.
18. End
Example table, switching from WEU to French/
Spain specification or vice versa, you need to
execute below:
Change volume setting
WEU => French/Spain
French/Spain => WEU
HD7806/50 /51 /52 /59
10
Adjusting normal/smooth 1-cup volume
step 6- 12
Push 7x 1-cups with water in tank
Push 7x 2-cups with water in tank
Restoring the Boiler_empty flag to production
default:
Sometimes it is needed, that the boiler of the
SENSEO have to be emptied.
This for instance in wintertime were the possibility
exists that the boiler becomes frozen during
transport e.g.
For those occasions, it is handy to restore the
Boiler_empty_flag again to production default.
Bringing the SENSEO back into production status,
has the benefit the flush routine will be activated
automatically when installed by the consumer, see
topic Automatic filling procedure.
How to SET the Boiler_empty_flag:
Keep the 1-cup button pressed while plugging
in the power plug of the appliance in the mains
socket.
The main switch LED will blink very rapidly for
approximately 1 second.
To check if the Boiler_empty_flag is really set,
reconnect the power plug to the mains a second
time and push the main switch. The main switch
LED should light continuously.
Adjusting short/strong 1-cup volume
16x 2cups without tank
16x 1cups without tank
step 13 - 17