Indoor Unit - Haier H2SM-18HC03/R2 Installation Manual

Haier h2sm-18hc03/r2: user guide
Hide thumbs Also See for H2SM-18HC03/R2:
Table of Contents

Advertisement

1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be
fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from
the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location Amm using a measuring tape
Holes for fixing the mounting plate
When the mounting plate is fixed side bar and lintel
Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten
the plate to the fixed mounting bar.
Refer to the previous article, "
position of wall hole.
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of Bmm in diameter,
slightly descending to outside the wall.
Install piping hole cover and seal it
off with putty after installation

Indoor unit

Thread
Weight
Fit the level line
When the mounting plate is first fixed ", for the
HSU-09HC03/R2(DB)
HSU-12HC03/R2(DB)
HSU-18HC03/R2(DB)
HSU-22HC03/R2(DB)
HSU-26H03/R2(DB)
Indoor side
Wall hole
Bmm
(Section of wall hole)
3
150mm
70mm
Amm Bmm
145
60
70
150
Outdoor side
Thickness
of wall
Piping hole pipe