FEATURES
•
4 PWM, low-voltage outputs
•
4 Analog, 0-10 low-voltage outputs
•
4 High-voltage relays – tied to low-voltage
outputs in Design Center
•
Twelve membrane style actuators and LED
status indicators
•
High resolution performance when dimming
•
Communicates via Vantage Station Bus
•
Housed in a custom, UL rated enclosure
- Part #LVOS-0-10-PWM-1 includes station
and enclosure
•
Enclosure configurations
- IAUX-2 – up to six stations per enclosure
- IAUX-4 – up to ten stations per enclosure
•
Override switch connections for ON and OFF
states of all loads collectively
Dimensions, HWD
Cover Dimensions, HWT
Station Only Dimensions, HWD
Weight with Box
LED Indicators
Ambient Operating Temperature
Relative Humidity
Firmware
Cooling
Manual Control
FreeRTOS™
Vantage
Low-Voltage Output 0-10-PWM Station
Installation Instructions • Instructions d'Installation • Instrucciones de Instalación
The Vantage LVOS-0-10-PWM-1 (LVOS) has four PWM and four analog
low-voltage outputs along with four high-voltage relays. All twelve
connections are independent from each other. The station is powered from
a universal input of 120-277 VAC 50/60Hz source. The high-voltage relays
are isolated from the station's high-voltage power supply. All outputs can be
manually controlled and monitored from the front of the station. An Override
switch may be connected allowing all the low-voltage loads and high-
voltage relays to be ON or OFF for fail-safe applications. The station comes
housed in a custom metal enclosure or may be ordered separately for
installation into Vantage's IAUX enclosure. Communication to the Vantage
System is via Station Bus.
TWO WAYS TO ORDER
Part #
LVOS-0-10-PWM-1
LVOS-0-10-PWM-P-1
*WARNING: This is not a DIN station and is not designed for DIN
rail. Vantage's auxiliary enclosures, IAUX-2 / IAUX-4 and LCAP44A-6
enclosures are ordered separately.
General
9" x 10.5" x 2.75" (22.86cm x 26.67cm x 6.98cm)
9.75" x 11.25" x 0.6" - 1/16" Thick (24.77cm x 28.58cm x 15mm-thick)
3.32" x 10.34" x 2.667" (8.43cm x 26.26cm x 6.77cm)
5.85lbs (2.65kg)
Microprocessor Status, Configuration, Loads
32-104°F / 0-40°C
Maximum 90%, non-condensing
Upgradeable via Station Bus
Convection
Overlay with control/status for each output
Real-time scheduling provided by FreeRTOS (www.freertos.org)
1
®
OVERVIEW
Description
Station with Single Enclosure: Low-Voltage
Output Station (PWM and 0-10) 120V-277V -
Comes in a custom Vantage supplied, UL rated
enclosure
LVOS-0-10-PWM Station only - For installing
in UL rated IAUX-2, IAUX-4, or LCAP series
enclosures*