Page 1
Hochdruck-Reinigungs-Systeme Betriebsanleitung - Operating Instruction Mobile Hochdruckreiniger Heißwasser Mobile High Pressure Cleaners Hotwater Typen - Series HD 623 - HD 723 - HD 640 - HD 840 - HD 1140 - HD 1240 HDE 800 HDB 1240 - HDB 1540 - HDD 1240 VORSICHT: Zur Inbetriebnahme der Hochdruckreiniger die Betriebsanleitung beachten.
Page 2
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Betriebsanleitung für Gerätetyp: Mobile Hochdruckreiniger Type of Machine:___________________________________________________ Heißwasser (Seite 5 bis 48) Ersatzteilkatalog Maschinen - Nr. : (ab Seite 105) Serial-Number:____________________________________________________ Operating Instruction Spannung, Hz: Voltage, Hz:______________________________________________________ Mobile High Pressure Cleaners Hotwater (Page 49 to 94) Verkaufsstelle, Datum: Spare parts catalogue Dealer, Date:______________________________________________________ (Page 105)
Page 3
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Vorwort Mit dem Erwerb eines mobilen EHRLE Hochdruckreinigers sind Sie der Besitzer eines Qualitätsprodukts, das sich auszeichnet durch: Bedienungsfreundlichkeit, Zuverlässigkeit, Umweltfreundlichkeit. Unsere Hochdruckreiniger erfüllen alle wesentlichen nationalen und internationalen Sicherheitsstandards und wurden von anerkannten Prüfinstituten freigegeben. Diese Betriebsanleitung enthält Hinweise zur Bedienung, Wartung und Instandsetzung...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Inhaltsverzeichnis 2.4.4 Inbetriebnahme und Bedienung des Typs HDD ..........37 Verwendung von Reinigungsmitteln (Chemie) ..........39 Außerbetriebnahme der Hochdruckreiniger ............40 Technische Beschreibung 2.6.1 Außerbetriebnahme der Typenreihe HD und HDE ..........40 Technische Beschreibung .................. 10 2.6.2 Außerbetriebnahme der Typenreihe HDB ............41 Allgemeines ......................
Page 5
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Bildverzeichnis Ersatzteilkatalog Ersatzteilkatalog ....................105 Bild 1 Hochdruckreiniger HD 623 bis HD 1240, HDE 800, Bauteile des Hochdruckreinigers ..............106 Seitenansicht rechts ..................12 Bedienungspult rechts für Typ HD ..............108 Bild 2 Hochdruckreiniger HD 623 bis HD 1240, HDE 800, Bedienungspult rechts für Typ HDE ..............
Die nachfolgende Tabelle zeigt die vier Kategorien der Hochdruckreiniger und Öffentliche Einrichtungen (z.B. Schwimmbäder, Flughäfen, Sanitäranlagen). ihren jeweiligen vorgesehenen Einsatzort. Neben der Reinigung von alltäglichen Verschmutzungen zeichnen sich die EHRLE Hochdruckreiniger vor alllem aus bei ölverschmierten Oberflächen, teerhaltigen Oberflächen, fetthaltigen Oberflächen, ö...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 1.3.1 Gesamtansichten der mobilen Hochdruckreiniger ölbeheizt (Typ HD) und elektrisch beheizt (HDE) Die beiden nachfolgenden Abbildungen zeigen die Seitenansichten (rechts, links) der Hochdruckreiniger: HD 623, HD 640, HD 723, HD 840, HD 1140, HD 1240, HDE 800. Z-0-00002.DWG Z-0-00001.DWG Gerätestecker mit Kabel Hochdruckschlauch...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Technische Daten 1.4.2 Technische Daten für HD 840, HD 1140 und HD 1240 1.4.1 Technische Daten für HD 623, HD 723 und HD 640 Die nachfolgende Tabelle zeigt die Technischen Daten für die Hochdruckreini- Die nachfolgende Tabelle zeigt die Technischen Daten für die Hochdruckreiniger des ger des Typs HD 840, HD 1140 und HD 1240.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 1.4.4 Technische Daten für HDB 1240, HDB 1540 und HDD 1240 1.4.3 Technische Daten für HDE 800 Die nachfolgende Tabelle zeigt die Technischen Daten für die Hochdruckreini- Die nachfolgende Tabelle zeigt die Technischen Daten für die Hochdruckreini- ger des Typs HDB 1240, HDB 1540 und HDD 1240. ger des Typs HDE 800.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Die Brennstoffpumpe (26) fördert den Brennstoff aus dem Brennstoffbehälter Allgemeine Funktion der Hochdruckreiniger (22) über den Brennstoffilter (24) zum Ölbrenner (27). Die Brennstoffmangelab- 1.5.1 Allgemeine Funktion der Typen HD, HDB und HDD schaltung (23) schaltet den Hochdruckreiniger bei Brennstoffmangel ab. Das Wasser aus dem Leitungsnetz fließt bei aktivierter Handspritzpistole (17) durch den Wassereingang (01) in den Schwimmerbehälter (02) (siehe auch Bild 7).
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 1.5.2 Allgemeine Funktion des Typs HDE Das Wasser aus dem Leitungsnetz fließt bei aktivierter Handspritzpistole (19) durch den Wassereingang (01) in den Elektroboiler (02) (siehe auch Bild 8). Im Elektroboiler (02) wird das Wasser über die elektrischen Heizstäbe (04) auf die voreingestellte Temperatur erwärmt.
Die Hochdruckreiniger dürfen nicht von Kindern betrieben werden. Die Hochdruckreiniger in Standardausführung dürfen nicht in feuer- und explosionsgefährdeten Räumen aufgestellt und Der Schallpegel für EHRLE Hochdruckreiniger beträgt unter Maximallast betrieben werden. Werden ölbeheizte Geräte in geschlossenen 82 dB (A). Sollte die Geräuschentwicklung durch die Anwendung des austreten- Räumen aufgestellt, ist für die Ableitung der Verbrennungsgase...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 2.3.2 Herstellen des Wasseranschlusses für den Hochdruckreiniger Die Verlängerungskabel müssen je nach verwendetem Hochdruckreinigertyp und Kabellänge folgende Drahtquerschnitte aufweisen: ACHTUNG Den Hochdruckreiniger nur mit klarem Wasser betreiben. Die Typenreihe HD: bis 30 m Länge Drahtquerschnitt 2,5 mm² Wassereingangstemperatur zum Hochdruckreiniger darf maximal Typenreihe HDE: 12 - 18 kW Heizleistung Drahtquerschnitt 6 mm²...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Inbetriebnahme und Bedienung 2.4.1 Inbetriebnahme und Bedienung der Typenreihe HD VORSICHT Der aus der Handspritzpistole austretende Wasserstrahl darf nicht auf Personen, Tiere oder unter Spannung stehende elektrische Bauteile oder Anlagen (Maschinen, Geräte, Leitun- gen, Steckdosen usw.) gerichtet werden. Elektrische Bauteile oder Anlagen vor dem Reinigen von der Stromversorgung abtrennen.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 2.4.2 Inbetriebnahme und Bedienung der Typenreihe HDE VORSICHT Der aus der Handspritzpistole austretende Wasserstrahl darf nicht auf Personen, Tiere oder unter Spannung stehende elektrische Bauteile oder Anlagen (Maschinen, Geräte, Leitun- gen, Steckdosen usw.) gerichtet werden. Elektrische Bauteile oder Anlagen vor dem Reinigen von der Stromversorgung abtrennen.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 2.4.3 Inbetriebnahme und Bedienung der Typenreihe HDB VORSICHT Der aus der Handspritzpistole austretende Wasserstrahl darf nicht auf Personen, Tiere oder unter Spannung stehende elektrische Bauteile oder Anlagen (Maschinen, Geräte, Leitun- gen, Steckdosen usw.) gerichtet werden. Elektrische Anlagen, Maschinen, Geräte oder Baugruppen vor dem Reinigen vom Netzanschluß...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme VORSICHT Der austretende Wasserstrahl übt nach dem Ziehen des 2.4.4 Inbetriebnahme und Bedienung des Typs HDD Startergriffs (11, Bild 14) eine Rückstoßkraft auf die Handspritzpistole aus. Das Strahlrohr und die Handspritzpistole VORSICHT Der aus der Handspritzpistole austretende Wasserstrahl darf gut festhalten.
Dabei die Dosierungsempfehlung auf den Gebindeetiketten der Reinigungsmittel beachten. VORSICHT Nur die von der Firma EHRLE zugelassenen Reinigungsmittel verwenden. Die Verwendung anderer Reinigungsmittel kann die Betriebssicherheit des Hochdruckreinigers beeinträchtigen. Den Reinigungsmitteltank (Beispiel siehe 10, Bild 1) mit dem zugelassenen Reinigungsmittel füllen.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 2.6.2 Außerbetriebnahme der Typenreihe HDB Für die Beimischung von Reinigungsmittel aus dem eingebauten Reinigungs- mitteltank (Beispiel siehe 10, Bild 1): Für die Außerbetriebnahme der Typen HDB 1240 und HDB 1540 wie folgt vor- Das Chemie-Dosierventil (5, Bild 1) von der Stellung "0" nach links drehen. gehen: Für die Beimischung von Reinigungsmittel aus einem externen Reinigungsmit- Chemie-Dosierventil (10, Bild 13) ggf.
2.7.1 Druckbehälterverordnung und Dampfkesselverordnung VORSICHT Die Wartung und Instandsetzung der Hochdruckreiniger dürfen nur EHRLE Hochdruckreiniger entsprechen der Druckbehälter- und Dampfkessel- von geschultem und qualifiziertem Fachpersonal durchgeführt werden. verordnung. Der Wasserinhalt beträgt weniger als 10 Liter, deshalb ist das Gerät kesselseitig frei von Aufstellungsvorschriften. Beim Arbeiten mit Temperaturen Vor den Maßnahmen zur Wartung oder Instandsetzung den...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 3.2.1 Tägliche Wartung 3.2.6 Entkalkung des Hochdruckreinigers Täglich oder nach ca. 8 Betriebsstunden des Hochdruckreinigers den Betriebs- Bei verkalktem Hochdruckreiniger steigt der Rohrleitungswiderstand an und druck ohne eingeschalteten Brenner prüfen. Liegt der Druck mehr als 5 bar das Überströmventil födert einen Teil des Wassers in den Kreislauf der Pum- über dem im Prüfprotokoll eingetragenen Betriebsdruck, muß...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme - Etronic-Steuerung ist defekt. 3.2.7 Überprüfen der Hochdruckschläuche VORSICHT Durch Hochdruckschläuche, die abgenutzt sind, eine geringe Hochdruckreiniger kommt nicht auf Druck Haltbarkeit haben, überaltert sind oder reparierte Hochdruck- schläuche können Personen verletzt werden. Durch das Wenn der Hochdruckreiniger nicht auf Druck kommt, gibt es fogende Möglich- Aufplatzen oder durch undichte Hochdruckschläuche kann keiten: heißes, unter Hochdruck stehendes Wasser oder Wasserdampf...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 3.3.2 Austausch von Bauteilen und Komponenten Die defekten Bauteile bzw. Komponenten gemäß den Darstellungen im Ersatz- teilkatalog (siehe Abschnitt 5) austauschen. Beim Austauschen nur vom Hersteller empfohlene Ersatzteile verwenden (siehe Ersatzteilkatalog im Anhang). Operating Instruction Mobile High Pressure Cleaner Hotwater Series HD 623 - HD 723 - HD 640 - HD 840 - HD 1140 - HD 1240...
Page 26
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Preface With purchasing the EHRLE High Pressure Cleaner you are the owner of a high quality product. Beside the outstanding features our High Pressure Cleaners are: Ease of operation Reliable Environmentally friendly Our High Pressure Cleaners meet national and international safety standards and have received the approval of international agencies and laboratories.
Page 27
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Table of content 2.6.2 Decommissioning the series HDB ..............87 2.6.3 Decommissioning the series HDD ..............87 Guidelines, Regulations, Certificates ..............88 Technical description 2.7.1 Guidelines for pressure vessels and steam boiler regulation ......88 Technical description ..................56 2.7.2 Guidelines for liquid sprayers ................
Page 28
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Wiring diagrams List of figures Series HD, Wiring Diagram ................. 96 Series HD with Flame Control, Wiring Diagram ..........98 Figure 1 High Pressure Cleaner HD 623 to HD 1240, HDE 600 and HDE 800, Series HDE, Wiring Diagram ................100 right side view ....................
Vehicles (cars, trucks, caterpillar), Sanitary facilities, airports, swimming pools etc. The table below shows the four categories in reference to work site. Beside cleaning of generally contaminated surfaces the EHRLE High Pressure Cleaners show its excellent features and optimum cleaning power when cleaning...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 1.3.1 Side views of High Pressure Cleaners oil fired (series HD) and electric heated (series HDE) The following figures show the High Pressure Cleaner side views (right, left) of series: HD 623, HD 640, HD 723, HD 840, HD 1140, HD 1240, HDE 800.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 1.3.2 Side views of High Pressure Cleaners with gasoline engine (series HDB) The following figures show the High Pressure Cleaner side views (right, left) of series: HDB 1240, HDB 1540, Z-0-00005.DWG Z-0-00020.DWG Rear view Front view Fuel oil tank High pressure hose connection Z-0-00019.DWG Fuel tank filler connection...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 1.3.3 Side views of High Pressure Cleaners with diesel engine (series HDD) The following figures show the High Pressure Cleaner side views (right, left) of series: HDD 1240 Z-0-00005.DWG Z-0-00004.DWG Rear view Front view Fuel oil tank High pressure hose connection Z-0-00003.DWG Fuel tank filler connection Discharge manifold...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Technical data 1.4.2 Technical data for series HD 840, HD 1140 and HD 1240 1.4.1 Technical data for series HD 623, HD 723 and HD 640 The table below shows the High Pressure Cleaner technical data for series The table below shows the High Pressure Cleaner technical data for series HD 840, HD 1140 and HD 1240.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 1.4.4 Technical data for series HDB 1240, HDB 1540 and HDD 1240 1.4.3 Technical data for series HDE 800 The table below shows the High Pressure Cleane technical data for series The table below shows the High Pressure Cleaner technical data for series HDB 1240, HDB 1540 und HDD 1240.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme General function of High Pressure Cleaner The fuel oil pump (26) conveys the fuel oil from the fuel oil container (22) through the fuel oil filter (24) to the oil burner (27). The low fuel cut off (23) swit- 1.5.1 General function of series HD, HDB and HDD ches off the High Pressure Cleaner, when the fuel oil container (22) is empty.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 1.5.2 General function of series HDE When the trigger gun (19) is activated, the water from the water system flows through water inlet (01) in to the boiler container (02) (see also figure 8). The water in the boiler container (02) is heated by the heating elements (04) to the adjusted temperature.
If the high pressure cleaner is operated not within direct visual contact of the operator, the oil burner must be equipped with a flame control (only series HD, For the EHRLE High Pressure Cleaner heating installation (series HDB and HDD).
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 2.3.2 Water supply connection for the High Pressure Cleaner Depending on High Pressure Cleaner type and extension cable length, the wire cross sections have to be as follows: CAUTION Operate the High Pressure Cleaner only with clean water. The Series HD: up to 30 m cable length wire cross section 2,5 mm²...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Commissioning and Operation 2.4.1 Commissioning and operating the series HD WARNING The High Pressure Cleaner jet must not be directed to persons, animals or voltage supplied electrical equipment (machines, de- vices, cables, electrical power outlets etc.). Disconnect electrical equipment from power outlet, before clean- ing.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 2.4.2 Commissioning and operating the series HDE WARNING The High Pressure Cleaner jet must not be directed to persons, animals or voltage supplied electrical equipment (machines, de- vices, cables, electrical power outlets etc.) supplied with voltage. Disconnect electrical equipment from power outlet, before clean- ing.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 2.4.3 Commissioning and operating the series HDB WARNING The High Pressure Cleaner jet must not be directed to persons, animals or voltage supplied electrical equipment (machines, de- vices, cables, electrical power outlets etc.). Disconnect electrical equipment from power outlet, before clean- ing.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme WARNING After pulling the starter grip (11, figure 14), the force of the water 2.4.4 Commissioning and operating the series HDD leaving the nozzle causes a kick-back at the trigger gun. The trigger gun and lance should be held firmly. WARNING The High Pressure Cleaner jet must not be directed to persons, animals or voltage supplied electrical equipment (machines, de-...
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme WARNING After turning on the engine switch, the force of the water leaving the nozzle causes a kick-back at the trigger gun. The trigger gun and lance should be held firmly. CAUTION After pulling the starter grip several times and the engine didn’t start, check the oil level at the oil filler cap (4, figure 16) after stop- ping the engine.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme For admixing the cleaning detergent from the cleaning detergent tank proceed 2.6.2 Decommissioning the series HDB as follows (example see 10, figure 1): For decommissioning the series HDB 1240 and HDB 1540 proceed as follows: Turn chemical metering valve (5, figure 1) from position "OFF" counterclock- Set the chemical metering valve (10, figure 13) to position “0”.
(see section 2.7.2) and “Emissions regulations“ (see section 2.7.4). The heating installation of the EHRLE High Pressure Cleaner underlie the regu- lations of fire equipments. According to these regulations oil- or gas fired high pressure cleaners have to be checked annually by your responsible district chimney sweep to ensure observance of the emission limit values.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 3.2.1 Daily maintenance 3.2.6 Descaling the High Pressure Cleaner Check daily or after approx. 8 hours of operation the operation pressure of the If there is any descaling in the High Pressure Cleaner the high pressure pipe re- High Pressure Cleaner with deactivated oil burner.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 3.2.7 Checking the high pressure hose High Pressure Cleaner doesn’t reach the operating pressure If the High Pressure Cleaner doesn’t reach the required operating pressure, the WARNING High pressure hoses with less durability and repaired high pres- following failures may occur: sure hoses are extremely dangerous for persons.
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme 3.3.2 Replacing components Replace defect components according to illustrations in the spare parts cata- logue (see section 5). For replacing components use only manufacturer recommended spare parts (see spare parts catalogue in section 5). Abschnitt 4 Stromlaufpläne HINWEIS Die nachfolgenden Stromlaufpläne zeigen die Verdrahtung für die Standardaus- führungen der Hochdruckreiniger.
Page 49
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Stromlaufpläne - Wiring Diagrams Serie HD, Stromlaufplan - Series HD, Wiring Diagram Betriebsstundenzähler 24 V - Hour meter 24 V #2752 Thermostat 0 - 150° C - Thermostat 0 - 150° C #2012 Druckschalter Pumpenkopf - Pressure switch pumphead #12632 Druckschalter Heizschlange - Pressure switch heatcoil...
Page 50
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Serie HD mit Flammenüberwachung, Stromlaufplan - Series HD with Flame Control, Wiring Diagram...
Page 51
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Serie HDE, Stromlaufplan - Series HDE, Wiring Diagram...
Page 52
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Serie HDB und HDD, Stromlaufplan - Series HDB and HDD, Wiring Diagram...
Page 54
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl Ersatzteile - Spare parts Ref. Description Part No. Quantity Grundrahmen - Frame 204701 Bauteile des Hochdruckreinigers - Components of High Pressure Cleaner Griff - Handle 2048 Haube - Cover 3504 Brennstofftank - Fuel oil tank 2049 Chemie Tank bei HDE-Typen - Chemical tank HDE-Series 2049...
Page 55
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl Bedienungspult rechts für Typ HD - Operation panel right for series HD Ref. Description Part No. Quantity Cekon-Stecker 16 Amp (HD 640, HD 840, HD 1140, HD 1240) - 2055 Cekon plug 16 Amp (HD 640, HD 840, HD 1140, HD 1240) Schuko-Stecker 16 Amp (HD 623, HD 723) - Schuko plug 16 Amp (HD 623, HD 723) 205501...
Page 56
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl Bedienungspult rechts für Typ HDE - Operation panel right for series HDE Ref. Description Part No. Quantity Cekon-Stecker 32 A - Cekon plug 32 A 205502 Cekon-Stecker 63 A - Cekon plug 63 A 205503 Hauptschalter - Main Switch 204601...
Page 57
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl Bedienungspult links HD 623, HD 640 Ref. Description Part No. Quantity Operation panel left HD 623, HD 640 Druckschalter 3/8“ - Pressure switch 3/8“ 5741 O-Ring 13,95x2,62 - O-ring 13,95x2,62 5826 Einschraubverschraubung XGE 12LR 3/8" - Screw Union XGE 12LR 3/8"...
Page 58
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl Bedienungspult links ( ab HD 723) - Operation panel left (ab HD 723) Ref. Description Part No. Quantity Druckschalter, 1/4“ - Pressure switch, 1/4“ 5750 Verteilerblock - Discharge block 5440 Dichtring Cu 17x21x2,0 - Sealing ring copper 17x21x2,0 2370 Winkeleinschraubverschr XWE6LR 1/4“...
Page 59
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl Ölbrenner - Oil burner Ref. Description Part No. Quantity Brennergehäuse - Burner housing 2062 Ansaugkanal 50 Hz - Air chanel 50 Hz 2063 Ansaugkanal 60 Hz - Air chanel 60 Hz 2423 Zündtransformator 230 V - Ignition transformer 230 V 200302 Zündtransformator 110 V - Ignition transformer 110 V 2413...
Page 60
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl Heizschlange mit Schwimmerbehälter - Ref. Description Part No. Quantity Heating coil with float container Wassermangelsicherung - Low water cut off 2748 Schlauchschelle 20-32 mm - Hose clamp 20-32 mm 3724 Saugschlauch 3/4" 440 mm - Suction hose 3/4" 440 mm 366701 Mutter 1/2"...
Page 61
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Sicherheitsgruppe HD 623, HD 640 - Safety parts HD 623, HD 640 Pos. Benennung Teil-Nr. Stückzahl Ref. Description Part No. Quantity Dichtring CU 17x21x2,0 - Sealing Ring Copper 17x21x2,0 2370 Verteilerblock Heizschlange Ausgang - Discharge Block Heating Coil Outlet 5764 Dichtring CU 18x22x2,0 - Sealing Ring Copper 18x22x2,0 2353...
Page 62
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Sicherheitsgruppe HD 723, HD 840 - Safety parts HD 723, HD 840 Pos. Benennung Teil-Nr. Stückzahl Ref. Description Part No. Quantity Dichtring CU 17x21x2,0 - Sealing Ring Copper 17x21x2,0 2370 Verteilerblock Heizschlange Ausgang - Discharge Block Heating Coil Outlet 5764 Dichtring CU 18x22x2,0 - Sealing Ring Copper 18x22x2,0 2353...
Page 63
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl Sicherheitsgruppe HD 1140, HD 1240 - Safety parts HD 1140, HD 1240 Ref. Description Part No. Quantity Dichtring CU 17x21x2,0 - Sealing Ring Copper 17x21x2,0 2370 Verteilerblock Heizschlange Ausgang - Discharge Block Heating Coil Outlet 5764 Dichtring CU 18x22x2,0 - Sealing Ring Copper 18x22x2,0 2353...
Page 65
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Druckregelventil - Unloader valve Pos. Benennung Teil-Nr. Stückzahl Ref. Description Part No. Quantity Selbstsichernde Mutter - Selfsecuring nut 13470000 Handrad - Hand wheel 11900012 Federplatte - Spring plate 13171001 Regulierungsfeder - Spring 10772027 Mutter - Nut 13477003 Spindel - Guide stud 13772022 Stift - Stud 11877000...
Page 66
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl 5.10.1 Pumpe HD 623, HD 640 - Pump HD 623, HD 640 Ref. Description Part No. Quantity Messing Kopf - Brass Manifold 44120341 Schraube M8x60 UNI 5931 - Screw M8x60 UNI 5931 99319200 Scheibe 8 - Washer 8 96701400 O-Ring 17,13x2,62 - O-ring 17,13x2,62 90384100...
Page 67
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl 5.10.2 Getriebe HD 623, HD 640 - Pump crankcase HD 623, HD 640 Ref. Description Part No. Quantity Drahtsprengring - Circlip 90063500 Kurbelwelle - Crankshaft 44021365 Buchse - Bushing 91856800 Schraube M8x25 UNI 5739 - Screw M8x25 UNI 5739 99306700 Scheibe 8, Schnorr - Washer 8, Schnorr 96701400...
Page 68
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl 5.10.3 Pumpenkopf zu HD 623, HD 640 - Ref. Description Part No. Quantity Pump head for HD 623, HD 640 Griff - Knob 36318751 Nutmutter - Ring nut 36318670 Mutter M28x1,5 - Nut M28x1,5 92293500 Mutter M8 UNI 5589 - Nut M8 UNI 5589 92221800...
Page 69
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl 5.11.1 Pumpe HD 723, HD 840 - Pump HD 723, HD 840 Ref. Description Part No. Quantity Messing Kopf - Brass Manifold 44120441 Schraube M8x60 UNI 5931 - Screw M8x60 UNI 5931 99317500 Scheibe 8 - Washer 8 96701400 O-Ring 17,13x2,62 - O-ring 17,13x2,62 90384100...
Page 70
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl 5.11.2 Getriebe HD 723, HD 840 - Pump crankcase HD 723, HD 840 Ref. Description Part No. Quantity Drahtsprengring - Circlip 90063500 Kurbelwelle - Crankshaft 44021365 Buchse - Bushing 91856800 Schraube M8x25 UNI 5739 - Screw M8x25 UNI 5739 99306700 Scheibe 8, Schnorr - Washer 8, Schnorr 96701400...
Page 71
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl 5.12 Pumpe HD 1140 - Pump HD 1140 Ref. Description Part No. Quantity Messing Kopf - Brass Manifold 47120141 Schraube M8x70 UNI 5737 - Screw M8x70 UNI 5737 99320600 Scheibe 8 UNI 1736 - Washer 8 UNI 1736 96702000 O-Ring 17,13x2,62 - O-ring 17,13x2,62 90384100...
Page 72
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme Pos. Benennung Teil-Nr. Stückzahl 5.13 Pumpe HD 1240 - Pump HD 1240 Ref. Description Part No. Quantity Messing Kopf - Brass Manifold 47120141 Schraube M8x70 UNI 5737 - Screw M8x70 UNI 5737 99320600 Scheibe UNI 1736 - Washer UNI 1736 96702000 O-Ring 17,13x2,62 - O-ring 17,13x2,62 90384100...
Page 76
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme ANHANG - ANNEX Notizen - Notes Prüfnachweis für Wiederholungsprüfung gemäß "Richtlinien für Flüssigkeitsstrahler" Test certificate according "Guidelines for Liquid Sprayers" 1. Prüfnachweis - Test certificate Datum - date _____________ nächste Prüfung - next test____________ ________________________ Stempel / Unterschrift Stamp / Signature ______________________________________________________________ 2.
Page 77
High-Pressure-Cleaning-Systems Hochdruck-Reinigungs-Systeme ANHANG - ANNEX Prüfnachweis für Wiederholungsprüfung gemäß "Richtlinien für Flüssigkeitsstrahler" Test certificate according "Guidelines for Liquid Sprayers" 5. Prüfnachweis - Test certificate Datum - date _____________ nächste Prüfung - next test____________ ________________________ Stempel / Unterschrift Stamp / Signature ______________________________________________________________ 6.