Load Share Gateway (LSG)
Manual
Software Version 1.xxxx
Manual 37442B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Load Share Gateway and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Woodward Load Share Gateway

  • Page 1 37442B Load Share Gateway (LSG) Manual Software Version 1.xxxx Manual 37442B...
  • Page 2 Provides other helpful information that does not fall under the warning or caution categories. Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward is believed to be correct and reliable. However, Woodward assumes no responsibility unless otherwise expressly undertaken.
  • Page 3 Minor corrections • Design and graphics adjustments New features Requirements: Load Share Gateway (LSG) with device revision A or higher. • New application mode: Load sharing of easYgen devices and GCP/MFR devices supported (Refer to “easYgen connected to GCP/MFR (CAN)” on page 12 for details).
  • Page 4: Table Of Contents

    Manual 37442B LSG - Load Share Gateway Content 1. G ..................6 HAPTER ENERAL NFORMATION Related Documents ..........................Overview ..............................8 2. I ...................... 9 HAPTER NSTALLATION Safety Precautions ........................... Regulatory Notes ............................. 9 Electrostatic Discharge Awareness ....................... 10 Mounting and Removal .......................... 10 Application Overview ..........................
  • Page 5 Manual 37442B LSG - Load Share Gateway Figures and Tables Figures Figure 2-1: Application – EGCP-2 ............................11 Figure 2-2: Application – GCP/MFR ............................12 Figure 2-3: Application – analog active power ......................... 13 Figure 2-4: Application – analog active and reactive power ..................... 14 Figure 2-5: Application –...
  • Page 6: Chapter 1. General Information

    Manual 37442B LSG - Load Share Gateway Chapter 1. General Information TECHNICAL REQUIREMENTS The Load Share Gateway (LSG) works only in combination with: • easYgen-3100/3200 (Package P2 – Software Version 1.12xx & 1.13xx) • easYgen-3100/3200 (Software Version 1.15xx or higher) •...
  • Page 7: Table 1-1: Manual - Overview

    Manual 37442B LSG - Load Share Gateway easYgen-2000 Series easYgen-2000 - Installation 37426 easYgen-2000 - Configuration 37427 easYgen-2000 - Operation 37428 DE37428 easYgen-2000 - Application 37429 easYgen-2000 - Interfaces 37430 easYgen-2000 - Parameter List 37431 DE37431 easYgen-2000 - Brief Operation Information...
  • Page 8: Overview

    LSG - Load Share Gateway Overview ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ The Load Share Gateway (LSG) is a next generation communication converter specifically designed to operate the easYgen-2000 / easYgen-3000 Series and legacy devices (RS-485 bus or analog load share line coupled) in one single load share network.
  • Page 9: Chapter 2. Installation

    Manual 37442B LSG - Load Share Gateway Chapter 2. Installation Safety Precautions ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ WARNING HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH • Only qualified workers should install this equipment. Such work should be performed only after read- ing this entire set of instructions.
  • Page 10: Electrostatic Discharge Awareness

    WARNING To prevent damage to electronic components caused by improper handling, read and observe the pre- cautions in Woodward manual 82715, Guide for Handling and Protection of Electronic Controls, Printed Circuit Boards, and Modules. Mounting and Removal ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡...
  • Page 11: Application Overview

    Manual 37442B LSG - Load Share Gateway Application Overview ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ The LSG is available in two different types: • Active power load share (P) • Reactive power load share (Q) The following figures show application examples for both LSG types (marked with P or Q).
  • Page 12: Easygen Connected To Gcp/Mfr (Can)

    Manual 37442B LSG - Load Share Gateway easYgen connected to GCP/MFR (CAN) The easYgen devices communicate via CAN bus among each other with an easYgen specific protocol which dif- fers from the GCP/MFR protocol. The LSG is able to connect GCP/MFR and easYgen devices in a single load share network on the same CAN bus.
  • Page 13: Easygen Connected To Legacy Device (Can/Analog)

    Manual 37442B LSG - Load Share Gateway easYgen connected to legacy device (CAN/Analog) The easYgen devices communicate via CAN bus among each other and therefore can´t communicate directly to analog legacy devices which have no CAN bus interface. The LSG is able to connect analog legacy devices and easYgen devices in a single load share network.
  • Page 14: Figure 2-4: Application - Analog Active And Reactive Power

    Manual 37442B LSG - Load Share Gateway Active and reactive power loadshare: On CAN (easYgen) the LSG for active power loadsharing is fixed to work as generator with address 16 the LSG for reactive power loadsharing to work as generator with address 15. For this reason it is not allowed, to set any easYgen to address 15 or 16.
  • Page 15: Figure 2-5: Application - Analog Active Power

    Manual 37442B LSG - Load Share Gateway Examples B: Active power loadshare: On CAN (easYgen) the LSGs are fixed to work as generator with addresses 15 and 16. For this reason it is not al- lowed, to set any easYgen devices to address 15 and 16.
  • Page 16: Chapter 3. Housing

    Manual 37442B LSG - Load Share Gateway Chapter 3. Housing Terminal and Interface Overview ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ 1. Power terminal block socket 2. RS-485 connector 3. CAN connector 4. Analog terminal block socket 5. Error indication LED 6. RS-485 / GCP/MFR CAN / Analog Status Indicator 7.
  • Page 17: Figure 3-2: Housing Lsg - Dimensions

    Manual 37442B LSG - Load Share Gateway Figure 3-2: Housing LSG – dimensions © Woodward Page 17/32...
  • Page 18: Chapter 4. Connection

    Manual 37442B LSG - Load Share Gateway Chapter 4. Connection WARNING All technical data and ratings indicated in this chapter are not definite! Only the values indicated in Chapter 7: Technical Data on page 30 are valid! The following chart may be used to convert square millimeters [mm²] to AWG and vice versa: mm²...
  • Page 19: Analog Load Share

    Manual 37442B LSG - Load Share Gateway Analog Load Share ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ Figure 4-2: Analog load share Terminal Description Analog Load Share V+ 2.5 mm² Analog Load Share V- 2.5 mm² Shield 2.5 mm² Table 4-3: Analog load share - terminal assignment ©...
  • Page 20: Interfaces

    Manual 37442B LSG - Load Share Gateway Interfaces ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ RS-485 Serial Interfaces Figure 4-3: RS-485 interface - overview Terminal Description not connected RS-485 (-) not connected not connected not connected RS-485 (+) not connected not connected Table 4-4: RS-485 interface - pin assignment...
  • Page 21: Figure 4-5: Rs-485 - Connection For Half-Duplex Operation

    Manual 37442B LSG - Load Share Gateway Half-Duplex on RS-485 Figure 4-5: RS-485 - connection for half-duplex operation NOTE Please refer to EGCP-2 manual 26076 / 26174 „Installation and Operation – Chapter 3. Electrical Instal- lation and Specifications”. This manual describes how the bus needs to be terminated. Is the LSG at the end of the RS-485 bus, a terminating resistor of 120 ohm needs to be connected to the Sub-D connector.
  • Page 22: Can Bus Interface

    Manual 37442B LSG - Load Share Gateway CAN Bus Interface The CAN baud rate is detected automatically. For the supported baud rates please refer to „Maximum CAN Bus Length“, Page 23. Figure 4-6: CAN bus - overview Terminal Description not connected...
  • Page 23: Figure 4-7: Interfaces - Can Bus - Termination

    • The configured baud rate is too high for wiring length • The CAN bus cable is routed in close proximity with power cables Woodward recommends the use of shielded, twisted-pair cables for the CAN bus (i.e.: Lappkabel Unitronic LIYCY (TP) 2×2×0.25, UNITRONIC-Bus LD 2×2×0.22).
  • Page 24: Bus Shielding

    Manual 37442B LSG - Load Share Gateway Bus Shielding All bus connections of the LSG are internally grounded via an RC element. Therefore, they may either be grounded directly (recommended) or also via an RC element on the opposite bus connection.
  • Page 25: Chapter 5. Configuration

    Manual 37442B LSG - Load Share Gateway Chapter 5. Configuration LSG Configuration ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ The LSG does not need to be configured. • • The LSG is receiving his operation mode via CAN from the easYgen with the lowest address. •...
  • Page 26: Easygen - Lsg Display Information

    Manual 37442B LSG - Load Share Gateway easYgen – LSG Display Information ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ If the LSG mode is set to 1 (EGCP-2) the icon “LSG” at the LDSS screen (easYgen) is twinkling if the CAN connection between easYgen and LSG is OK. This icon is permanent, if an EGCP-2 in automatic mode is de- tected on the RS-485 bus.
  • Page 27: Egcp-2 Configuration

    Manual 37442B LSG - Load Share Gateway EGCP-2 Configuration ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ • One EGCP-2 must be configured as the system master. It is recommended to configure the master unit with device number 1 and priority number 1. The EGCP-2 device numbers must not be configured as 8, because the LSG is using this device number.
  • Page 28: Chapter 6. Operation

    Manual 37442B LSG - Load Share Gateway Chapter 6. Operation Status LEDs ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ The three LEDs indicate the status of the module. The LEDs assist maintenance personnel in quickly identifying wiring or communication errors. A LED test is exercised at power-up. After power up the LEDs are building a “running light” until the correct CAN baud rate is found.
  • Page 29: Functional Test

    Manual 37442B LSG - Load Share Gateway Functional Test ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ Testing the CAN Bus Communication If the connection between the easYgen and the LSG is working properly, the LSG is recognized as a further “ea- sYgen” by the easYgen devices. The LSG appears with the address 16. If a second LSG is used for analog reac- tive Load Share this will appear with address 15.
  • Page 30: Chapter 7. Technical Data

    Manual 37442B LSG - Load Share Gateway Chapter 7. Technical Data Nameplate Item number Item revision number Serial number (numerical) Serial number (barcode) Date of production (year-month) Type Description (short) Type Description (long) Details Technical data Approval Approvals Ambient variables --------------------------------------------------------------------------------------------- Power supply (SELV) ..............
  • Page 31: Chapter 8. Environmental Data

    Manual 37442B LSG - Load Share Gateway Chapter 8. Environmental Data Vibration--------------------------------------------------------------------------------------------------------- Frequency Range – Sine Sweep ..............5Hz to 100Hz Acceleration ......................4G Frequency Range - Random ................. 10Hz to 500Hz Power Intensity ................... 0.015G²/Hz RMS Value ....................1.04 Grms Standards ..........................
  • Page 32 Phone +49 (0) 711 789 54-0 • Fax +49 (0) 711 789 54-100 stgt-info@woodward.com Homepage http://www.woodward.com Woodward has company-owned plants, subsidiaries, and branches, as well as authorized distributors and other authorized service and sales facilities throughout the world. Complete address/phone/fax/e-mail information for all locations is available on our website (www.woodward.com).