Technical Specifications; Accessories; Warranty; Ce Declaration - Kärcher IP 120 Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
Electrical connection
Voltage
Current type
Frequency
Connected load
Maximum allowed net impedance
Dry ice
Supply pressure, liquid carbon dioxide
Max. moisture content, liquid carbon dioxide
Oil content, liquid carbon dioxide
Diameter of dry ice pellets
Max. pellet production
Feed pressure for liquid carbon dioxide for max. pellet production
Dimensions
Width
Depth
Height
Weight, empty
Weight, full
Sound pressure level (EN 60704-1)
Hydraulic oil as per DIN 51524, part 2
Quality
Viskosity
Amount of oil

Accessories

CO
Detector
2
Scale 600x800 mm with
control
Scale 1000x1000 mm with
control
Hydraulic oil, 20 l
IP 120
Extruder plate 16 mm
Extruder plate 3 mm
Extruder plate 1.7 mm
Volume control PCS 120
Spare parts package
IP 220
Extruder plate 16 mm
Volume control PCS 220
Spare parts package
18
English

Technical specifications

– Only use accessories and spare parts
which have been approved by the man-
Order No.
ufacturer. The exclusive use of original
6.574-105.0
accessories and original spare parts en-
sures that the appliance can be operat-
6.574-179.0
ed safely and troublefree.
– At the end of the operating instructions
6.574-180.0
you will find a selected list of spare parts
that are often required.
– For additional information about spare
6.288-223.0
parts, please go to the Service section
at www.kaercher.com.
The warranty terms published by our com-
Order No.
petent sales company are applicable in
6.574-060.0
each country. We will repair potential fail-
ures of your appliance within the warranty
6.574-061.0
period free of charge, provided that such
6.574-200.0
failure is caused by faulty material or de-
fects in fabrication. In the event of a warran-
6.574-181.0
ty claim please contact your dealer or the
6.574-175.0
nearest authorized Customer Service cent-
er. Please submit the proof of purchase.
We hereby declare that the machine de-
scribed below complies with the relevant
Order No.
basic safety and health requirements of the
6.574-002.0
EU Directives, both in its basic design and
construction as well as in the version put
6.574-178.0
into circulation by us. This declaration shall
6.574-176.0
cease to be valid if the machine is modified
without our prior approval.
V
Hz
kW
Ohm
MPa (bar)
ppm
mm
kg/h
MPa (bar)
mm
mm
mm
kg
kg
dB(A)
16/13 as per ISO 4406
l
Spare parts

Warranty

CE declaration

IP 120
IP 220
400
3~
50
4,0
0.147+j0.092
1,6...2,1 (16...21)
1,3...2,1 (13...21)
66
absolutely free of oil absolutely free of oil
3
120
1,75 (17,5)
1320
700
1439
340
360
85
ISO VG 32
35
Product:
Dry ice pelletiser
Type:
1.574-xxx
Relevant EU Directives
98/37/EC
2006/95/EC
2004/108/EC
Applied harmonized standards
EN 55014–1: 2006
EN 55014–2: 1997 + A1: 2001
EN 626–1
EN 60204–1
EN 61000-3-2: 2006
EN 61000–3–3: 1995 + A1: 2001 + A2:
2005
EN 61000–3–11: 2000
Applied national standards
-
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
Head of Approbation
CEO
Alfred Kärcher GmbH Co. KG
Alfred Kärcher-Str. 28 - 40
D - 71364 Winnenden
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
400
3~
50
5,6
0.169+j0.106
66
3
220
1,7 (17)
1560
800
1400
495
540
89
ISO VG 32
60

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip 220

Table of Contents