Chapter 1: Introduction

General information

The BP4 blood pressure monitor uses the oscillometric method for measuring Non-Invasive Blood Pressure (NIBP).
NIBP measurement is based on the principle that pulsatile blood flow through an artery creates oscillations of the arterial
wall. The oscillometric device uses a blood pressure cuff to sense these oscillations that appear as tiny pulsations in cuff
pressure. The oscillometric devices measure the amplitude of pressure changes in the occluding cuff as the cuff deflates
from above systolic pressure. The amplitude suddenly increases as the pulse breaks through the occlusion in the artery.
As the cuff pressure decreases further, the pulsations increase in amplitude, reach a maximum (which approximates to
the max amplitude pressure (MAP)), and then diminish. The oscillometric method measures the MAP and determines
the systolic and diastolic pressures.
In this monitor, we have IHB technology (IHB = Irregular heartbeat). The IHB technology analyses pulse frequency and
detects irregular heartbeat during blood pressure measurement. If an irregular heartbeat occurs during the measurement,
the IHB symbol is displayed. IHB does not replace a cardiac examination, but it serves to detect pulse irregularities at an
early stage. This is automatically done by the device without the need for any adjustments. Unlike most common
monitors, BP4 monitor can distinguish between arrhythmias and artefacts due to great technical and physiological
precision in measurements.
The device estimates the systolic blood pressure during inflation and inflates to a proper cuff pressure (approximately
30-40 mmHg above the patient's systolic pressure). The advantage is Personalized Inflation for maximum comfort.
This user manual contains important safety information and provides step-by-step instructions for using the blood
pressure monitor. Read this information carefully before you use the device and save it for future reference.

Benefits

Ability to measure in different pressure ranges.
Ability to measure in dialysis patients, pregnant women.
Ability to measure in low gains.
Automatic saving of blood pressure measurements (60 records per user).
Simple User-Interface - 4 button operation & large display.
Inflation level is automatically set.
Working with batteries (4 x 1.5V "AA" batteries or rechargeable lithium batteries) or AC adapter.
IHB technology - Irregular Heartbeat Technology analyses pulse frequency and detects irregular heartbeat during
blood pressure measurement.
Comfortable cuff for all common arm sizes.
Cuff holder & handgrip for carrying.

Medical Purpose

The device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult and
pediatric patient population with arm circumference ranging from 21 cm to 55 cm (from 8 inches to 22 inches).

Intended User

This device should be used by a medical professional.

Patient Population

This device is intended for use on adults and children of age 3-years and older.

Environment

The instrument is designed for use in physicians' offices, hospitals, clinics and other medical facilities.

Measurement Parameter

Non-Invasive Blood Pressure