Chapter 2: System settings

Keys function

ON/OFF (START/STOP) button

If the device is off, pressing this key will turn on the device. When the device is on and when the measurement is not
taken, the device switches off if the key is held down for 3 seconds.
By pressing and releasing this key in less than three seconds, the measurement process starts or stops. This key is also
used to exit the setting modes (User, Date and Time) and review the memory (put the device in standby mode).

MODE button

Pressing this key activates the various features as follows:
With the first press of the key, the selection of user 1 or user 2 is done. In this case, the user symbol on the screen
starts blinking. By pressing the up or down key, user 1 or 2 is selected.
Pressing the key again activates the mode of displaying the saved information (archive mode). The memory icon
flashes and the last saved measurement of the selected user is displayed immediately. By pressing the up or down
keys, other measurements are displayed with the date and time of measurement. If the measurement was
performed incorrectly, the error code is displayed. The last measurement is always displayed at first.
By pressing the key again, the year number setting mode is activated. The year number is displayed as a blink
and changes by pressing the up or down keys.
Pressing the key again activates the month number setting mode. The month number is displayed as a blink and
changes by pressing the up or down keys.
By pressing the key again, the day number setting mode is activated. The day number is displayed as a blink and
changes by pressing the up or down keys.
Pressing the key again activates the clock number setting mode. The clock number is displayed as a blink and
changes by pressing the up or down keys.
By pressing the key again, the minute number setting mode is activated. The minute number is displayed as a
blink and changes by pressing the up or down keys.
By pressing the key again, the above procedure is repeated.
Note
The set numbers are for setting the time and date controller only and has no other use.
At each step of the adjustment, pressing the START / STOP key saves the changes and
puts the device in standby mode.
The symbol " " indicates that the battery has enough energy to measure blood pressure.
When the battery symbol flashes, it means that the battery charge is running out and
needs to be charged.
If the battery charge is too low, the device will not be able to perform the measurement
and turns off.
The saved records are shown and sorted by their date. (the last record is on top of the list
with number 1).
The adjusted user number is saved and will not change with each record or power off.
Irregular heartbeats will be displayed by the corresponding icon when they are detected.
In case of unsuccessful records, the corresponding error code will be displayed and saved
in archive. (for more information refer to Error Messages & Troubleshooting chapter).
Chapter 2: System settings
11