9.27. Remove the C3-Board

1. Remove the Contact metal bottom. (See section 9.24.)
2. Disconnect the flexible cables (CB10, CB11, CB12,
CB13, CB14 and CB15).
3. Disconnect the flexible cables (C31 and C36).
4. Disconnect the connector (C35).
5. Remove the screws (×4

9.28. Remove the AL frames

1. Remove the screws (×12
frames.
2. Remove the screws (×4
fixing metals.
) and remove the C3-Board.
, ×2
) and remove the AL
each) and remove the Corner

9.29. Replace the Plasma panel

Caution:
Remove the Plasma panel section from the servicing
stand and lay on a flat surface such as a table (covered
by a soft cloth) with the Plasma panel surface facing
downward.
A new Plasma panel itself without Contact metals is fragile.
To avoid the damage to new Plasma panel, carry a new
Plasma panel taking hold of the Contact metals.
1. Place a carton box packed a new Plasma panel on the
flat surface of the work bench.
2. Open a box and without taking a new Plasma panel.
3. Attach the Cabinet assy and each P.C.Board and so on,
to the new Plasma panel.
*When fitting the Cabinet assy, be careful not to allow any
debris, dust or handling residue to remain between the
Front glass and Plasma panel.