Tyco Healthcare KANGAROO 924 Quick Start Manual

Tyco Healthcare KANGAROO 924 Quick Start Manual

Enteral feeding pump

Advertisement

Table of Contents

SECTION I
General Information .................................................................................................................
SECTION II
Operating Procedures ...............................................................................................................
Battery ....................................................................................................................................
Beginning Administration .........................................................................................................
SECTION III
Alarms .....................................................................................................................................
SECTION IV
Cleaning ...................................................................................................................................
Important User Information ......................................................................................................
General Cleaning Directions ......................................................................................................
Directions for Cleaning Pump Housing .......................................................................................
Directions for Cleaning Pump Power Cord ...................................................................................
Directions for Cleaning Drop Detector ........................................................................................
Directions for Cleaning OPTIX Lock .............................................................................................
Directions for Cleaning Rotor Assembly ......................................................................................
Preventive Maintenance ...........................................................................................................
SECTION V
Troubleshooting Guide ..............................................................................................................
Biotech Mode ...........................................................................................................................
SECTION VI
Factory Service .........................................................................................................................
SECTION VII
Specifications ...........................................................................................................................
Symbols ...................................................................................................................................
SECTION VIII
Warranty ..................................................................................................................................
kANGAROO 924
Status: Review Routing On: CR10000186 Doc#: AW10001678
11/10/2006 Artwork#s: WN 182493-01 Job#: 14761
English
Enteral Feeding Pump

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KANGAROO 924 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tyco Healthcare KANGAROO 924

  • Page 1: Table Of Contents

    Directions for Cleaning Rotor Assembly ..................Preventive Maintenance ......................SECTION V Troubleshooting Guide ......................Biotech Mode ........................... SECTION VI Factory Service ......................... SECTION VII Specifications ........................... Symbols ........................... SECTION VIII Warranty ..........................kANGAROO 924 Enteral Feeding Pump 11/10/2006 Artwork#s: WN 182493-01 Job#: 14761...
  • Page 2: General Information

    Status: Review Routing On: CR10000186 Doc#: AW10001678 Section I General Information The Tyco Healthcare Group LP KANGAROO™ 924 Enteral Feeding Pump is a rotary peristaltic pump designed to regulate the flow rate of enteral feedings. Among the features provided by this pump are: •...
  • Page 3 Status: Review Routing On: CR10000186 Doc#: AW10001678 Figure 1 Figure 2 1. Handle Pole Clamp 2. Upper Drip Chamber Guide 10. Pole Clamp Knob (including drop sensor) 11. AC Light 3. Tubing Guide 12. Vol CLR Light 4 Lower Drip Chamber Guide 13.
  • Page 4: Operating Procedures

    Status: Review Routing On: CR10000186 Doc#: AW10001678 Section II Operating Procedures NOTE: To disconnect AC power it is necessary to unplug power cord from the AC wall outlet. AC Light On whenever pump is plugged in. Vol CLR Light On when volume delivered has been cleared. Powers the pump (See Figure 3 for location).
  • Page 5: Battery

    Replace the battery pack only with the same type and rating of battery. Beginning Administration Below are general instructions for inserting all Tyco Healthcare Group LP Pump Sets into the KANGAROO 924 Enteral Feeding Pump. 1. Press ON. 2. Wait while pump performs system check. (Displays “...
  • Page 6 Example of proper placement of Pump Set in KANGAROO 924 Feeding Pump. Note: When in use with an IV pole, assure feeding bag is set so that the top of the fluid column is 28 inches above the top of the pump.
  • Page 7 Section III Alarms The Tyco Healthcare Group LP KANGAROO 924 Enteral Feeding Pump has been designed to provide audible and visible alarms under several conditions where proper performance cannot be maintained. When an alarm occurs, press the START/HOLD button on the pump and perform the necessary procedures to correct the alarm condition.
  • Page 8: Important User Information

    General Cleaning Directions Cleaning of KANGAROO 924 pumps must be performed as follows: CAUTION Disconnect pump from A.C. power source before cleaning. Upon completion of cleaning, do not connect to A.C.
  • Page 9: Directions For Cleaning Pump Housing

    Status: Review Routing On: CR10000186 Doc#: AW10001678 • A mild detergent should be used for general cleaning. If necessary, the pump may be cleaned with a 10:1 water and hypochlorite mixture, however, repeated cleaning with this solution can damage the plastic pump case. Isopropyl alcohol applied with a damp (not wet) cotton swab may be used for cleaning difficult-to-reach areas, such as the drop sensor and inside the A.C.
  • Page 10: Preventive Maintenance

    The KANGAROO 924 pump contains no user serviceable parts. User maintenance consists of cleaning the exterior of the pump as stated in the cleaning section of this manual. All other maintenance is to be performed by the user’s appropriately qualified technical personnel.
  • Page 11: Biotech Mode

    Pump set has been improperly placed onto pump. – Check to make sure only KANGAROO 924 Pump Set has been placed onto the pump. Check to make sure OPTIX connector on pump set has been properly positioned into the OPTIX lock on pump.
  • Page 12: Factory Service

    Technical information will be made available on request to allow the users appropriately qualified technical personnel to repair the parts of the equipment designated by the manufacturer as repairable. Refer to the KANGAROO 924 Pump service manual for more service information.
  • Page 13 In the event that the environmental conditions for transport and storage are exceeded, return the unit for factory service. In the event that the specified storage time limit is exceeded, within the environmental limits specified, perform the performance tests prior to use. Refer to the KANGAROO 924 service manual for servicing information. kANGAROO™ 924...
  • Page 14 Serial Number Tyco Healthcare Group LP (hereinafter referred to as T.H.G.L.P.) warrants that each KANGAROO 924 Feeding Pump will be free from defects in materials and workmanship under normal use and service for a period of sixty (60) days from the date of delivery by T.H.G.L.P. to the first purchaser.
  • Page 15 Status: Review Routing On: CR10000186 Doc#: AW10001678 JOB NO....................14761 ARTWORK NO................182493 PACKAGE TYPE ..............DOM CD manual SIZE ...................8.5" X 11" PRINTED ..................1 SIDE INK COLOR ..................Black BAR CODE INK COLOR ................N/A 11/10/2006 Artwork#s: WN 182493-01 Job#: 14761...

Table of Contents