CFM AXP100 Installation & Maintenance

CFM AXP100 Installation & Maintenance

In-line duct fans

Advertisement

Quick Links

Installation & Maintenance
AXP
IN-LINE DUCT FANS
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Advertisement

Table of Contents
loading

Summary of Contents for CFM AXP100

  • Page 1 Installation & Maintenance IN-LINE DUCT FANS READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE...
  • Page 2: Safety Instructions

    SAFETY INSTRUCTIONS NOTICE AXP in-line duct fans are not explosion proof and should not be used when a potentially explosive situation exists. Do not use where temperatures will exceed 122 F/50 C. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, INJURY TO PERSONS, PLEASE READ THESE INSTRUCTIONS CAREFULLY Before servicing or cleaning the unit, ensure that the electrical service to the fan is locked in the “OFF”...
  • Page 3 AXP IN-LINE DUCT FANS AXP fans are made of white plastic. Delivery set includes: • Fan -1 • Fan bracket - 2 Depending on model, fan is compatible with 4” (100 mm), 5” (125mm), 6” (150mm), 8” (200mm), 10” (250mm), or 12” (300mm) diameter duct. AXP-C fans are equipped with a pre-wired 120V power cord.
  • Page 4 TYPICAL FAN INSTALLATION Fans may be mounted in ventilation shafts either vertically or horizontally. (Figure 1) An air duct at least 40 inches (1 meter) long should be connected to the inlet. The outlet should always be connected to an air duct. (1 meter) Figure 1...
  • Page 5: Fan Installation

    FAN INSTALLATION WARNING Disconnect and lock out power supply before performing any installation work. Working on or near energized equipment could result in death or serious injury. Fan installation is shown in Figures 2-7.The airflow direction should match that indicated on the fan housing.
  • Page 6: Wiring Diagrams

    WIRING DIAGRAMS WHITE GREEN BLACK TERMINAL CAPACITOR BLOCK 120 VOLT SUPPLY FROM FUSE PANEL AXP FAN MOTOR Figure 8 HOUSE JUNCTION BOX GREEN AUTOMATIC GROUND SWITCH SCREW 120V AC, 60Hz STANDARD HOUSE POWER WALL SOCKET EARTH GROUND AXP-C FAN Figure 9...
  • Page 7: Recommended Maintenance

    RECOMMENDED MAINTENANCE WARNING Make sure to disconnect the fan from the power mains prior to any cleaning. Proper maintenance (Figure 10-17) includes periodic cleaning of the fan surfaces from dirt and dust. The impeller blades require thorough cleaning every 6 months. Remove the self-tapping screws (Figures 12) and disconnect the grill from the casing.Wipe the fan blades with a soft cloth soaked in a mild detergent, avoiding dripping on the electric motor.
  • Page 8: Acceptance Certificate

    ACCEPTANCE CERTIFICATE The AXP fan has been duly certified as serviceable. AXP100 AXP125 AXP150 AXP200 AXP250 AXP300 AXP100-C AXP125-C AXP150-C AXP200-C AXP250-C AXP300-C Manufactured on (date): Date of sale: Sold by: (name of trading enterprise, stamp of store) CONNECTION CERTIFICATE...