CFM AXC Series Installation & Maintenance

CFM AXC Series Installation & Maintenance

Bathroom ventilation kit

Advertisement

Quick Links

WARNING
Only qualified personnel should work on electrical equipment. Working on or
near energized equipment could result in death or serious injury.
1. If the fan fails to start, consult wiring diagram to ensure proper connection.
2. Check the incoming supply for proper voltage.
3. Ensure that the electrical service to the fan is locked in the "OFF" position.
4. Use a meter to test for continuity across the fan motor leads.
5. If the motor leads show continuity, rewire the fan.
6. Turn on the electrical supply and restart.
7. If fan fails to start, please contact factory.
WARNING
Disconnect and lock out power supply before performing any maintenance.
Working on or near energized equipment could result in death or serious injury.
1. Fan bearings are sealed. No additional lubrication is necessary.
2. Periodic inspection, based upon usage, should be performed to ensure that the fan impeller
is not obstructed. The fan should be inspected a minimum of every six (6) months.
3. Excessive fan noise or vibration may indicate an obstructed impeller.
4. To inspect and clean impeller:
a) Remove the duct from the fan inlet and remove any obstruction from the impeller.
b) Reconnect the duct to the fan.
c) Turn power supply on.
TERMINAL
BLOCK
AXC FAN
MOTOR
Continental Fan Manufacturing Inc.
203 Eggert Road
Bu alo, New York 14215
TROUBLESHOOTING
RECOMMENDED MAINTENANCE
WIRING DIAGRAM
CAPACITOR
WHITE JUMPER
NOTE: JUMPER MUST BE USED WHEN MOTOR IS
OPERATED WITHOUT VARIABLE SPEED CONTROLLER
Continental Fan Canada Inc.
12-205 Matheson Blvd E
Mississauga, Ontario L4Z 3E3
1-800-779-4021 • www.continentalfan.com
GREEN
WHITE
BLACK
Continental Fan Manufacturing Inc.
117 VOLT SUPPLY
FROM FUSE PANEL
AXC Bath-I&M-1602
6274 Executive Blvd.
Dayton, Ohio 45424

Advertisement

loading

Summary of Contents for CFM AXC Series

  • Page 1 TROUBLESHOOTING WARNING Only qualified personnel should work on electrical equipment. Working on or near energized equipment could result in death or serious injury. 1. If the fan fails to start, consult wiring diagram to ensure proper connection. 2. Check the incoming supply for proper voltage. 3.
  • Page 2 Installation & Maintenance BATHROOM VENTILATION KIT READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE...
  • Page 3 SAFETY INSTRUCTIONS NOTICE AXC in-line duct fans are not explosion proof and should not be used when a potentially explosive situation exists. Do not use where temperatures will exceed 140 F/60 C. 1. Ensure that the electrical service to the fan is locked in the “OFF” position. Do not re-establish power supply until fan and activation device are completely installed.
  • Page 4 FAN INSTALLATION WARNING Disconnect and lock out power supply before performing any installation work. Working on or near energized equipment could result in death or serious injury. STEP 1. FAN LOCATION For optimum performance, the AXC in-line duct fan should be mounted near the termination of the duct, close to an outside vent.