Download Print this page

Briggs & Stratton EnergyTrak Install And User Manual page 10

Advertisement

Operating Profile Descriptions
Grid-Tied Backup
Parameter
Solar Distribution Priority
Enable Charging
Enable AC Charging
Enable feed to Utility
Enable discharge to Load when PV present
Enable discharge to Load when PV absent
Grid-Tied Backup with Time-of-Use
Parameter
Solar Distribution Priority: On-Peak
Solar Distribution Priority: Off-Peak
Enable Charging
Enable AC Charging
Enable feed to Utility
Enable discharge to Load when PV present
Enable discharge to Load when PV absent
Setting
Battery > Load > Grid
Enabled
Enabled
Enabled
Disabled
Disabled
Setting
Load > Battery > Grid
Battery > Load > Grid
Enabled
Enabled
Disabled
Enabled
Enabled
E N E R G Y T R A K U S E R M A N U A L
Grid-Tied Zero Export
Parameter
Solar Distribution Priority
Enable Charging
Enable AC Charging
Enable feed to Utility
Enable discharge to Load when PV present
Enable discharge to Load when PV absent
Grid-Tied Solar
Parameter
Solar Distribution Priority
Enable Charging
Enable AC Charging
Enable feed to Utility
Enable discharge to Load when PV present
Enable discharge to Load when PV absent
Off-Grid
Parameter
Solar Distribution Priority
Enable Charging
Enable AC Charging
Enable feed to Utility
Enable discharge to Load when PV present
Enable discharge to Load when PV absent
|
1 8
Setting
Load > Battery
Enabled
Enabled
Disabled
Enabled
Enabled
Setting
Grid
Disabled
Disabled
Enabled
Disabled
Disabled
Setting
Load > Battery
Enabled
Disabled
Disabled
Enabled
Enabled
E N E R G Y T R A K U S E R M A N U A L
|
1 9

Advertisement

loading