RAMFAN EX50Li Owner's Manual

All purpose-battery ventilator
Hide thumbs Also See for EX50Li:

Advertisement

Quick Links

FlowPath
Control
Owner's Manual
GEN II
ALL PURPOSE-BATTERY VENTILATOR
San Diego
Luxembourg
Dubai
Ningbo | Singapore
|
|
|

Advertisement

Table of Contents
loading

Summary of Contents for RAMFAN EX50Li

  • Page 1 FlowPath Control ™ Owner's Manual GEN II ALL PURPOSE-BATTERY VENTILATOR San Diego Luxembourg Dubai Ningbo | Singapore...
  • Page 2: Table Of Contents

    All product information in the publication is based on the most current information available at the time of printing. Euramco Group, Inc. reserves the right to make changes at Main Interface ..........................6 anytime without notice. Adjusting Angle ..........................7 Operational Modes ........................8 RAMFAN products are warranted against manufacture defect. Failure to AC Operation ........................8 properly maintain product will invalidate warranty coverage. Please visit DC Operation ........................8 www.euramco.com for warranty details. Connection of Battery Pack ..................... 8-9 Battery Operation Procedures ....................10...
  • Page 3: Unit Description

    AWG 14 (2.5 mm Do Not Touch Heat Sink or Lights knobs: high, low, & off. Hold to change. The LED knob selects the scene lights output level in >150 ft (> 50m) AWG 12 (4 mm a row. Clockwise Progression: Off Full Half Off. The integrated controller is EMI-protected to prevent interference with radio communication. Specifications A simple Control Panel on the top of controller controls all functions. Model EX50Li 18"/46 cm EL5500 / EL5500-230 Order# Motor 1.20 Hp / 0.89 kW, BLDC DC: 90 minutes (four battery packs) Runtime @ Max. Speed DC: 45 minutes (two battery packs) AC: Unlimited Universal Input: 85-264V 1Φ, 50/60 Power AC Battery System...
  • Page 4: Adjusting Angle

    Main Interface Adjusting Angle Perform this procedure to adjust the position of the ventilator. Use your hand to unscrew the tilt adjustment knob, and then lock it in place from above, and held in the Intellisense inclined position by tightening the knob. For negative tilt, use the negative tilt bracket. This provides tilt up/down adjustment, from -10 to + 34 degrees. NO PWR DC PWR FAULT STORAGE AC PWR MODE PUSH FOR PUSH FOR WAKE | STOP BAT. FAULT Loosen LIGHTS SPEED Tighten Number Symbol Indicate Function Wake Button / Emergency Stop Button Press and hold WAKE button to start. Negative tilt bracket Tilt adjustment knob (Accessory) Maximum Speed (DC) Button...
  • Page 5: Operational Modes

    2. Status LED Light will automatically turn green, displaying the status “Ventilator is connected on AC Power Supply”. 40V & 52V 3. Start the ventilator by using the Speed Control knob to the desired speed. battery packs Note: You can keep the batteries on their location without charging the battery. Battery Indicator Lights will turn off because there is no battery charging interchangeable when ventilator is running on AC. LB9114 4. When the fan is powered off, Status LED Light will automatically turn off after 1 hour and the battery Indicator Lights will redisplay battery charge level of each battery pack detected. The ventilator will begin charging the battery packs after 60 minutes of idle time. DC Operation Connection of Battery Pack • Plug the ventilator connector cable (red) into the battery connector. • Set the installation index on the battery with the cable, lining up with the cable connector. • Press the connector lock and rotate the red piece clockwise (a quarter turn to the right) LB9113 Rev B in the most careful way possible. • Align the edge of the battery pack with holder under the red line where it says, “Align battery EX50Li” and firmly slide the battery in the direction of the arrow as shown in the illustration until a loud click is heard. • Gently pull up the yellow handle to remove the battery from the holder.
  • Page 6: Battery Operation Procedures

    Battery Operation Procedures Battery Operation Procedures Please full charge battery before first use • When AC is disconnected and Speed Control is off (speed = 0), the controller and battery(s) will enter a sleep mode to conserve the battery power after 60 minutes of no Using one or two Batteries activity. • The EX50Li allows the option of using one or two battery packs. • To wake the ventilator, push and hold WAKE | STOP Button on Control Panel. Battery Status LED Light will show white solid for the status. The unit will return to • When using one battery, simply plug the battery into either one of the two battery sleep mode if not used within 10 minutes. connectors (left, right or both). • The ventilator starts at the lower speed = 0. Speed will vary by 11 levels - from 11 • Be sure to secure the unused battery connector by placing electrical tape over the (highest) to 0 (off). Turn clockwise to increase speed. At level 11 (the highest), if keep contacts. turning the control knob clockwise, the speed will not change, it will stay at highest speed all the time. To slow down, turn counterclockwise. • When powered on, the system will identify quantity of batteries and locations used. • If you want to increase the speed, push and hold the MAX Button Ventilator • For a true redundant system, two batteries are recommended. Status LED Light will flash white for the status. Remember that this will only work when 2 batteries are connected to the ventilator and when it is operating exclusively on DC • When using dual batteries, it’s important that both batteries be of the same charge current source (battery).
  • Page 7: Battery Status Indicator Lights

    Charging Procedure Battery Status Indicator Lights Make sure the battery pack is connected correctly to the ventilator, as described above in On the control panel there are 2 sets of lights: on the top side of the battery lights indicate “Connection of Battery Pack”. the charge level in the battery attached to the left side of the ventilator, on the bottom side of the battery lights indicate the charge level in the battery attached to the right side of the • The next step is to leave the ventilator off. During charging, the battery indicator lights ventilator. will flash. The battery charge level can be recognized by the number of lights that are constantly lit. Intellisense • When batteries and AC are connected, the batteries will begin charging after 60 minutes of idle time. NO PWR DC PWR FAULT STORAGE AC PWR MODE • Indicator lights will show charge state during charging. Charging should complete in PUSH FOR PUSH FOR about 5 hours, with the Battery Status Indicator lights turning green. Should the Speed WAKE | STOP Control be turned counterclockwise on during the charge, charging will stop, and the ventilator will start. Charging will begin again after 60 minutes of idle time.
  • Page 8: Storage/Transport Modes

    AC Power Cord Storage/Transport Modes Lithium-ion cell manufacturers recommend that battery cells be stored at 30% state This battery fan was designed to replace corded AC fans, optimizing cordless operations. of charge (SoC) for best long-term health and stability. Further, IATA (International Air The AC power cord is designed to be removable for the convenience of those users who Transport Association) Dangerous Goods Regulations (DGR) state that all lithium-ion choose to operate cordless. batteries must not exceed 30% SoC at time of shipment. The AC power connector is a ”Push-Pull” locking system where the outer (blue) slide must RAMFAN battery-powered fans built with Intellisense E3 controllers are equipped be pulled back, in line with the cable, to securely engage connector. with integrated “Storage/Transport Mode” to make it easy to comply with storage recommendations and transport regulations by automatically discharging installed battery • When AC power is needed, push (blue) connector onto (black) inlet on fan controller. pack(s) to 30% SoC. Check that it is securely engaged. • When disconnecting the AC power cord from fan, pull back on (blue) slide to disengage and gently remove. Store in marked frame position when not in use. Intellisense CORD NO PWR DC PWR FAULT STORAGE STORAGE AC PWR MODE PUSH FOR PUSH FOR WAKE | STOP BAT.
  • Page 9: Lithium-Ion Battery Maintenance Guidelines

    Maintenance and Disposal Lithium-Ion Battery Maintenance Guidelines Battery packs do require routine maintenance and care to maximize their useful life and • DO NOT disassemble the ventilator for maintenance reasons. maintain warranty coverage. Read and follow the guidelines in this manual to safely use your lithium-ion battery packs and achieve battery life span. • Do not loosen screws on control box without contacting Euramco customer service. They are torqued to a setting to achieve water tightness. Overview • Completely unravel power cord and place unit on a flat, stable surface. Clean ventilator According to leading cell manufacturers (LG, Samsung, Panasonic), the estimated life of a periodically to remove accumulated dust or particles from ventilator guards, impeller lithium-ion battery is 500 charge cycles. When stating approximate useful life of a battery blade and heat sink in rear of controller (ribbed). Use only biodegradable detergents. If in units of “charge cycles,” cell manufacturers define this as the point where the battery power washing, avoid controller housing especially gaskets and control panel. capacity (Ah) is reduced to 80% of original. This means battery is not “dead” after 500 charge cycles, but runtime is significantly reduced, and replacement should be considered. • Contact factory for replacement parts and installation instructions. To order spare parts call Euramco Group +1.619.670.9590 or theteam@euramco.com Partial discharge of lithium-ion batteries is fine. There is no “memory effect” and the battery does not need periodic full discharge cycles to prolong life. • Always dispose of your battery pack according to federal, state and local regulations. Storage • Even discharged batteries contain some energy. Before disposing of, use electrical tape to cover the terminals to prevent the battery pack from short circuit. When storing, remove battery packs from fan and store in a dry and cool location. Avoid extreme temperatures.
  • Page 10: Maintenance Schedule

    (2) Check immediately if dropped, or damage may affect water ingress protection. (3) These items should be serviced by your RAMFAN servicing dealer, unless you have the proper tools and are mechanically proficient. Refer to RAMFAN service manual for service procedures.
  • Page 11: Declaration Of Conformity

    80 years and is the world’s only recognized authority for the development of standards and measurement of air movement. Equipment Description: EX50Li – 18”/46cm Battery Powered PPV, Variable Speed, 85-250VAC (EL5500 / EL5500-230) EX150Li – 18”/46cm Battery Powered PPV, Variable Speed, 85-250VAC...
  • Page 12 Parts Exploded View EX50Li Gen II 8X 40 #8 OF EL6015 #3 OF EL6015 5X 12 CONCAVE SIDE TOWARD TILT PLATE See parts index (pg. 24)
  • Page 13: Plug Types

    Parts Exploded View Plug Types EX50Li Gen II Index The EX50Li is suitable for worldwide applications. Both a voltage & frequency converter is not needed. The unit includes a simple removable cord that allows the unit to operate up to Component Description Bubble # Part # 250 VAC, 50 Hz and 60 Hz: IMPELLER, 5 BLADE 17.65" 1.8HP@3800RPM BL226 Mainly used in Type Order # SHROUD, MOLDED, 18"/460mm GH4015 North and Central America, Japan EL-CUS-4762 EX50Li SHROUD COVER ASSEMBLY EL2300 France, Blegium, Germany, Austria, the EL-CEU-4762 Netherlands (and most European countries) BATTERY MOUNT ASSEMBLY R2-MOUNT360AHU United Kingdom, Ireland, Malta, Malaysia and EL-83070-4762 RUBBER FOOT, 50 DURO FZ-MM9873 Singapore KNOB, 1/4-20 INSERT...
  • Page 14 SM-EX50LI GEN II REV J MADE IN THE USA 031722 Use with all US Firefighting LUXEMBOURG MIDDLE EAST – UAE CHINA literature 2746 Via Orange Way 1 Rue Edmond Reuter, Jebel Ali FTZ, Dubai A11, No. 1 Jinxi Road Spring Valley, CA 91978 USA 5326 Contern, Luxembourg Phone: +1 (619) 670-9590 x114 Qingshuipu, Zhenhai, Zhejiang Toll Free: (800) 472-6326 Phone: +352-621377200 Fax: +1 (619) 670-7345 Ningbo, China 315221 Phone: +1 (619) 670-9590 Fax: +352-26008056 theteam@euramcosafety.com Phone: +86-574-87979390 Fax: +1 (619) 670-7345 theteam@euramcosafety.com Fax: +86-574-87979391 theteam@euramcosafety.com saleschina@euramcosafety.com...

This manual is also suitable for:

El5500El5500-230

Table of Contents