RAMFAN EX50Li Owner's Manual

All purpose-battery ventilator
Hide thumbs Also See for EX50Li:

Advertisement

Quick Links

FlowPath
Control
Owner's Manual
ALL PURPOSE-BATTERY VENTILATOR
San Diego
Luxembourg
Dubai
Ningbo | Singapore
|
|
|

Advertisement

Table of Contents
loading

Summary of Contents for RAMFAN EX50Li

  • Page 1 FlowPath Control ™ Owner's Manual ALL PURPOSE-BATTERY VENTILATOR San Diego Luxembourg Dubai Ningbo | Singapore...
  • Page 2: Table Of Contents

    All product information in the publication is based on the most current information available at the time of printing. Euramco Group, Inc. reserves the right to make changes at Specifications ........................5 anytime without notice. Main Interface ..........................6 Plug Types ............................7 RAMFAN products are warranted against manufacture defect. Failure to Adjusting Angle ..........................8 properly maintain product will invalidate warranty coverage. Please visit Operational Modes ........................9 www.euramco.com for warranty details. AC Operation ........................9 DC Operation ........................9 Connection of Battery Pack ....................9-10...
  • Page 3: Unit Description

    Hot Surface! >150 ft (> 50m) AWG 12 (4 mm Do Not Touch Heat Sink or Lights The integrated battery chargers will charge one or two fully discharged battery packs in 4 hours or less. LED scene lights are integrated into the ventilator shroud and 3-intensity infinite switch knobs: high, low, & off. Hold to change. The LED knob selects the scene lights output level in a row. Clockwise Progression: Off Full Half Off. Specifications The integrated controller is EMI-protected to prevent interference with radio Model EX50Li 18"/46 cm communication. Order# EL5500 / EL5500-230 0.8 Hp / 0.6 kW Motor A simple Control Panel on the top of controller controls all functions. DC: 90 minutes (four battery packs) Runtime @ Max. Speed DC: 45 minutes (two battery packs) AC: Unlimited Universal Input: 85-264V 1Φ, 50/60 HZ Power AC...
  • Page 4: Main Interface

    Plug Types Main Interface The EX50Li is suitable for worldwide applications. A voltage converter is not needed. The unit includes a simple removable cord that allows the unit to operate up to 250 VAC: Intellisense Mainly used in Type Order # NO PWR DC PWR FAULT North and Central America, Japan EL-CUS-4762 STORAGE AC PWR DC MAX MODE PUSH FOR PUSH FOR France, Blegium, Germany, Austria, the EL-CEU-4762 WAKE | STOP Netherlands (and most European countries) United Kingdom, Ireland, Malta, Malaysia and EL-83070-4762 Singapore Australia, New Zealand, Papua New Guinea and EL-84040-4762 LIGHTS SPEED Argentina BAT.
  • Page 5: Adjusting Angle

    3. Start the ventilator by using the Speed Control knob to the desired speed. Note: You can keep the batteries on their location without charging the battery. Loosen Battery Indicator Lights will turn off because there is no battery charging when ventilator is running on AC. Tighten 4. When the fan is powered off, Status LED Light will automatically turn off after 1 hour and the battery Indicator Lights will redisplay battery charge level of each battery pack detected. The ventilator will begin charging the battery packs after 60 minutes of idle time. 5. Battery Packs do not charge while ventilator is running. DC Operation Negative tilt bracket Tilt adjustment knob (Accessory) Connection of Battery Pack • Plug the ventilator connector cable (blue) into the battery connector: For confined space rescue operations, you can place the ventilator directly on top of a manhole. Tilt range from -90 to +90 degrees. Note that those positions can direct airflow downward or upward • Set the installation index on the battery with the cable, lining up with the cable connector. • Press the connector lock and rotate the blue piece clockwise (a quarter turn to the right) in the most careful way possible. • Align the edge of the battery pack with holder under the red line where it says, “Align battery EX50Li” and firmly slide the battery in the direction of the arrow as shown in the illustration until a loud click is heard.
  • Page 6: Battery Operation Procedures

    1.25 x .875 in ALIGN MATERIAL MainStock: TEC4911 4Mil Vinyl Flex White TC Vinyl UL 50#SCK w/Permanent Adh COLOR Black • The EX50Li offers a true redundant dual battery system. BATTERY HISTORY - LB9114 EX50Li • When using two batteries of identical charge level, batteries are connected in parallel to Revision Description Date increase significantly the total runtime and airflow performance.
  • Page 7: Run Time

    Charging Procedure Battery Operation Procedures Make sure the battery pack is connect correctly into the ventilator, as described above in • When AC is disconnected and Speed Control is off (speed = 0), the controller and “Connection of Battery Pack”. battery(s) will enter a sleep mode to conserve the battery power after 60 minutes of no activity. • The next step is to leave the ventilator off. During charging, the battery indicator lights will flash. The battery charge level can be recognized by the number of lights that are • To wake the ventilator, push and hold WAKE | STOP Button on Control Panel. constantly lit. Battery Status LED Light will show white solid for the status. The unit will return to sleep mode if not used within 10 minutes. • If both batteries and AC are connected, the batteries will begin charging after 60 minutes of idle time. If only one single battery is connect, the battery will begin • The ventilator starts at the lower speed = 0. Speed will vary by 11 levels - from 11 charging after 120 minutes of idle time. (highest) to 0 (off). Turn clockwise to increase speed. At level 11 (the highest), if keep turning the control knob clockwise, the speed will not change, it will stay at highest • Indicator lights will show charge state during charging. Charging should complete in speed all the time. To slow down, turn counterclockwise. about 5 hours, with the Battery Status Indicator lights turning green and all the five Fuel Gauge lights on the battery turning red. Should the Speed Control be turned counterclockwise on during the charge, charging will stop, and the ventilator will start. • If you want to increase the speed, push and hold the MAX Button Ventilator Charging will begin again after 15 min of idle time. Status LED Light will flash white for the status. Remember that this will only work when 2 batteries are connected to the ventilator and when it is operating exclusively on DC •...
  • Page 8: Fuel Gauge

    Battery Status Indicator Lights The Fuel Gauge On the control panel there are 2 sets of lights: on the top side of the battery lights indicate The Battery Fuel Gauge provides battery status information using five red LEDs. the charge level in the battery attached to the left side of the ventilator, on the bottom side of the battery lights indicate the charge level in the battery attached to the right side of the Press the Fuel Gauge button to display the lights. The fuel gauge lights will remain lit for ventilator. approximately five seconds. The numbers represent each LED and the grid is how they're laid out: Intellisense NO PWR DC PWR FAULT STORAGE AC PWR DC MAX MODE PUSH FOR PUSH FOR WAKE | STOP LIGHTS SPEED BAT. FAULT If the battery is charging, the green indicator lights will horizontally scroll from left-to- right, Fuel Gauge Lights Diagnosis Solution turning solid green when the battery is fully charged.
  • Page 9: How To Activate "Storage/Transport Mode

    Storage/Transport Modes AC Power Cord This battery fan was designed to replace corded AC fans, optimizing cordless operations. AC Lithium-ion cell manufacturers recommend that battery cells be stored at 30% state power cord is designed to be removable for the convenience of those users who choose to of charge (SoC) for best long-term health and stability. Further, IATA (International Air operate cordless. Transport Association) Dangerous Goods Regulations (DGR) state that all lithium-ion batteries must not exceed 30% SoC at time of shipment. AC power connector is a ”Push-Pull” locking system where the outer (blue) slide must be pulled back, in line with the cable, to securely engage connector. RAMFAN battery-powered fans built with Intellisense E3 controllers are equipped with integrated “Storage/Transport Mode” to make it easy to comply with storage • When AC power is needed, push (blue) connector onto (black) inlet on fan controller. recommendations and transport regulations by automatically discharging installed battery Check that it is securely engaged. pack(s) to 30% SoC. • When disconnecting AC power cord from fan, pull back on (blue) slide to disengage and gently remove. Store in marked frame position when not in use. CORD Intellisense STORAGE NO PWR DC PWR FAULT STORAGE AC PWR DC MAX MODE PUSH FOR...
  • Page 10: Lithium-Ion Battery Maintenance Guidelines

    Lithium-Ion Battery Maintenance Guidelines Maintenance and Disposal • DO NOT disassemble the ventilator for maintenance reasons. Battery packs do require routine maintenance and care to maximize their useful life and maintain warranty coverage. Read and follow the guidelines in this manual to safely use • Do not loosen screws on control box without contacting Euramco customer service. your lithium-ion battery packs and achieve battery life span. They are torqued to a setting to achieve water tightness. Clean ventilator periodically Overview to remove accumulated dust or particles from ventilator guards. According to leading cell manufacturers (LG, Samsung, Panasonic), the estimated life of a • Assembly screws are torqued to a specified value to achieve water tightness. lithium-ion battery is 500 charge cycles. When stating approximate useful life of a battery Completely unravel power cord and place unit on a flat, stable surface. Clean ventilator in units of “charge cycles,” cell manufacturers define this as the point where the battery periodically to remove accumulated dust or particles from ventilator guards, impeller capacity (Ah) is reduced to 80% of original. This means battery is not “dead” after 500 blade and heat sink in rear of controller (ribbed). Use only biodegradable detergents. If charge cycles, but runtime is significantly reduced, and replacement should be considered. power washing, avoid controller housing especially gaskets and control panel. Partial discharge of lithium-ion batteries is fine. There is no “memory effect” and the battery • Contact factory for replacement parts and installation instructions. To order spare does not need periodic full discharge cycles to prolong life. parts call Euramco Group +1.619.670.9590 or theteam@euramco.com Storage • Always dispose of your battery pack according to federal, state and local regulations. When storing, remove battery packs from fan and store in a dry and cool location. Avoid • Even discharged batteries contain some energy. Before disposing of, use electrical tape extreme temperatures.
  • Page 11: Maintenance Schedule

    (2) Check immediately if dropped, or damage may affect water ingress protection. (3) These items should be serviced by your RAMFAN servicing dealer, unless you have the proper tools and are mechanically proficient. Refer to RAMFAN service manual for service procedures.
  • Page 12: Certification

    Performance certified is for installation type A - Free inlet, Free oulet. Performance ratings do not include the effects of appurtenances (accessories). RAMFAN’s fire fighting PPV Series outperforms larger blowers in their class with their precision balanced TurboForce Impellers that maximize airflow. These PPV blowers have proven to be effective in controlling airborne contaminates, replacing interior air, removing heat and supplementing fixed ventilation systems.
  • Page 13 SM-EX50LI REV H MADE IN THE USA 080621 Use with all US Firefighting LUXEMBOURG MIDDLE EAST – UAE CHINA literature 2746 Via Orange Way 1 Rue Edmond Reuter, Jebel Ali FTZ, Dubai A11, No. 1 Jinxi Road Spring Valley, CA 91978 USA 5326 Contern, Luxembourg Phone: +1 (619) 670-9590 x114 Qingshuipu, Zhenhai, Zhejiang Toll Free: (800) 472-6326 Phone: +352-621377200 Fax: +1 (619) 670-7345 Ningbo, China 315221 Phone: +1 (619) 670-9590 Fax: +352-26008056 theteam@euramcosafety.com Phone: +86-574-87979390 Fax: +1 (619) 670-7345 theteam@euramcosafety.com Fax: +86-574-87979391 theteam@euramcosafety.com saleschina@euramcosafety.com...

This manual is also suitable for:

Ex150li

Table of Contents