SECTION 7: INSTALLATION

WARNING
Fire Hazard
Keep all flammable objects, liquids and
vapors the minimum required safe distances
to combustibles away from heater.
Some objects will catch fire or explode when
placed close to heater.
Failure to follow these instructions can result
in death, injury or property damage.
WARNING
Burn Hazard
Keep all persons, especially children, away
from heater.
Do not touch any part of the heater.
Heater is very hot.
Failure to follow these instructions can result
in death, injury or property damage.

7.1 Choose Location for Heater

When selecting a suitable mounting location for the
CGTH-Series heater it is important to consider the
following:
• The heater must meet the minimum mounting
height requirement of 7' (2.1 m) above the floor.
For aircraft hangars and public garages, the
heater must meet the minimum mounting height
requirement of 8' (2.4 m) above the floor.
• The proposed mounting location allows for the
minimum required safe distances from combusti-
bles such as vehicles, wood, gasoline and flam-
mable objects, liquids and vapors.
14 of 29
• The proposed location of the heater will not
restrict motion of passageway doors or windows.
• The proposed location will not interfere with oper-
ation of the overhead garage door or allow the
door to enter the minimum required safe dis-
tances from combustibles.
• The proposed location will provide the best cover-
age of the total area to be heated.
• Consideration be given to the types of vehicles
that will be parked in the garage (cars, vans,
boats, RV's, etc.).
• The proposed location will allow for the required
safe distances from combustibles with respect to
the vehicles parked in the garage.
• The proposed location will allow the required utili-
ties (i.e.: gas and electric) and venting to be
installed (maximum vent length is 10' (3 m).
• Sufficient clearances will exist to allow for easy
access to the service door.
• Overhead structural members (rafters, beams,
etc.) are accessible for attaching the heater.
• To ensure the heater is placed in a approved
application.

7.2 General Venting Guidelines

WARNING
Carbon Monoxide Hazard
Heaters must be exhausted outside.
Use materials supplied.
This heater needs fresh air for safe operation
and must be installed so there are provisions
for adequate combustion and ventilation air.
Failure to follow these instructions can result
in death or injury.
Regardless of the venting arrangement that will be
connected to the heater, the following general guide-
lines for venting must be followed:
1. See Page 15, Figure 8 for allowable vent
terminal locations.