Do you have a question about the Dimension Master Plus and is the answer not in the manual?
Questions and answers
Anne
February 4, 2025
What is the setting for measuring room temperature?
1 comments:
Mr. Anderson
February 10, 2025
The Dimension Master Plus does not have a specific setting for measuring room temperature. However, it uses automatic temperature compensation to ensure measurement accuracy within a temperature range of 32ºF to 100ºF (0ºC to 38ºC). If the internal temperature differs from the ambient temperature, you may compensate by adding or subtracting 1% of the measured distance for each 10ºF (5.5ºC) difference.
This answer is automatically generated
Related Manuals for Calculated Industries Dimension Master Plus
INTRODUCING THE DIMENSION MASTER PLUS ... 3 Background............4 Key Functions............7 New and Improved Features......11 HOW TO USE THE DIMENSION MASTER PLUS..16 Taking Accurate Measurements ......16 Taking a Linear Measurement......16 Taking an Area Measurement......18 Volume Measurements ........18 Large Room Measurements .......19 Entering Dimensioned Values......20...
Introducing the ® Dimension Master Plus The Dimension Master Plus (v2.0) is a high-tech measuring tool that uses the latest in ultrasonic technology. This tapeless measure and calculator allows you to take quick and accurate measure- ments with the touch of a button. You can measure a single room in seconds or a whole building in minutes.
“target” surface and returns to the unit as an echo. The Dimension Master Plus then determines how long the echo took to return and calculates a linear distance reading, while internally compensating for variables such as temperature.
Page 5
4 AAA Alkaline batteries are used to power the Dimension Master Plus. If a “lo batt” reading ap- pears on the display, the batteries need to be re- placed by removing the door on the back of the unit.
Page 6
7-digit standard display using a 5/4 rounding. Automatic Shutoff The Dimension Master Plus is designed to shut it- self off after approximately 7 minutes of non-use. Any value shown on the display is cleared at this point. All values stored in the memory registers re- main unchanged.
“none” or “Error” is displayed, depending on the measurement situation. The unit will also display “Error” if you make an incorrect entry, try to per- form invalid dimensional calculations (i.e., adding areas and volumes together) or the resulting answer is beyond the range of the calculator. “Error” will also appear if you enter a mathematical impossibil- ity, such as division by zero.
Page 8
[Sq] Square Key — Used with a dimension key (feet, inches, yards, meters) to label entry as an area or “square” value (e.g., 10 Square Feet). [ / ] Fraction Bar Key — Used to separate the nu- merator and denominator when entering frac- tions.
Page 9
[LxWxH] Volume Key — Calculates or recalls volume based on Length, Width and Height. If one of these values is not entered, “None” displays. Repeated presses toggle through the available units of measure. [Yards] Yards Key — Labels a value as Yards. [Con- vert] [Yards] converts whole or decimal num- bers of a different unit of measure to Yards.
Page 10
[Convert] Conversion Key — Converts between units of measure and accesses secondary functions. Re- peated presses scroll through available units of measure: Linear: Feet-Inch-Fraction, Decimal Feet, Inch- Fraction, Decimal Inch, Yards and Meters Square: Square Feet, Square Yards and Square Meters Cubic: Cubic Feet, Cubic Yards and Cubic Meters Additional Functions Using [Convert]...
Used to test the LCD. Lights all display seg- ments. [M+] Memory Key — Adds displayed value to the cumulative memory. New and Improved Features The Dimension Master Plus (v2.0) gives you the following new features: • Three new “Measuring Beam Modes” Smart Mode Narrow Mode Wide Mode •...
Page 12
Measuring Beam Modes One of the most important new features of the Di- mension Master Plus (v2.0) is the addition of three different measuring beam modes: Normal Mode is the default setting and can be used for most measuring situations. Narrow Mode is used for higher accuracy within a confined space (narrow hallways, corri- dors, etc.) or when there is a need to eliminate inter-...
Page 13
[On] is pressed twice, or the unit is powered down. Greater Math Accuracy Equipped with a new, more powerful Integrated Circuit Chip, the Dimension Master Plus performs math calculations faster and with more accuracy. Greater Fractional Accuracy With the addition of three new fraction denomina- tor settings, greater fractional accuracy can be achieved.
Page 14
Method 2 Use the keystrokes below to select and “set” the de- sired fraction denominator setting: KEYSTROKE SETTING KEYSTROKE SETTING [Convert] [1] 1/16” [Convert] [2] 1/2” [Convert] [3] 1/32” [Convert] [4] 1/4” [Convert] [6] 1/64” [Convert] [8] 1/8”* Note: 1/8” is the default setting. When a fraction denominator setting other than the default setting of 1/8”...
Page 15
[LxW] or [LxWxH] keys re- calculate the results for each available unit of measure. Expanded Memory Functions Your Dimension Master Plus includes the follow- ing functions for greater flexibility during use: Function Keystroke Add displayed value to Memory [M+] Display &...
How to Use the Dimension Master Plus Taking Accurate Measurements Be sure to hold the Dimension Master Plus still and directly parallel to the target area while taking a measurement. The Dimension Master Plus may give an inaccurate reading or a none/error message if it is moved or held at an angle while you are at- tempting to take a measurement.
Page 17
Note: If the Dimension Master Plus is un- able to measure the distance, either the word “none” or “Error” (depending on the measurement situation) will appear on the display.
Taking an Area Measurement Measure the length of the room as described in steps 1-4 above. When the measurement is displayed, press [Length] to enter the value. Measure the width of the room. When the measurement is displayed, press [Width] to enter the value. Press [LxW] to display the area calculation.
Note: Area and volume measurements can also be calculated by entering values manu- ally into [Length], [Width] and [Height]. Large Room Measurements If you want to measure a room beyond the 60-foot range, take two linear measurements. Stand in the center of the room and take one measurement in one direction.
Entering Dimensioned Values When entering dimensioned values, enter the larg- est dimension first; feet before inches, inches before fractions. Enter fractions by first entering the nu- merator (value above the line), then press the [/] key, then the denominator (value below the line). Note: The first valued dimension entered in a problem determines the format of the result.
length of the second wall is 12 feet. What is the to- tal wall length and wall area? STEP KEYSTROKE DISPLAY Enter length of one 16 [Feet] 2 [Inch] 16– 2 FEET INCH wall: 16– 2 Enter into memory: [M+] FEET INCH Enter 2nd wall’s 12 [Feet]...
Convert to cu. yards [Convert] [Yards] 5.146605 CU YDS Memory Functions Use the [Convert] [−] [M+] keys to subtract from the Memory: STEP KEYSTROKE DISPLAY Clear calculator: [On] [On] Enter values into 10 [Feet] 5 [Inch] [M+] 10- 5 FEET INCH memory: 5 [Feet] 3 [Inch] [M+] 5- 3...
1) Make sure the unit is parallel to the surface that is being measured. 2) Check to see if there are objects ob- structing the measuring beam. Note: For technical problems not shown above, please contact Calculated Industries, Inc. technical support at 702/885-4975. 8VHU·V *XLGH ³ ...
However, we recommend that you do not leave your Dimension Master Plus in very cold or very hot conditions (e.g., sunlight in a car), as the unit will then require more time to adjust to ambi- ent temperature.
Page 27
A strong wind will tend to affect the maxi- mum measurement range. Moisture — Your Dimension Master Plus is a high precision measuring device that is open to the atmosphere. For this reason, it should not be used in conditions (i.e., rain, mist, etc.) where moisture...
,0(16,21 $67(5 (187=(5+$1'%8&+ – Neue, verbesserte DMP-Tastatur mit Display ™ Der neue und verbesserte Dimension Master Plus von CII bietet viele der beliebtesten Funktionen unserer Bestseller-Produktreihe Construction ® Master . Vor der erstmaligen Anwendung des Dimension Master Plus sollten Sie kurz die folgenden Seiten durchlesen.
Page 29
Erhöhte Bruchgenauigkeit Mit den zusätzlichen drei Brucheinstellungen kann eine höhere Buchgenauigkeit erzielt werden. Der Nenner kann mit einer der folgenden Methoden eingestellt werden: 1. Methode Drücken Sie [Rcl] und [/], um die aktuelle Brucheinstellung anzuzeigen. Drücken Sie [+] und [–], um die verfügbaren Optionen anzuzeigen. Wenn die gewünschte Einstellung angezeigt ist, drücken Sie eine beliebige andere Taste, um diese zu wählen.
Page 30
Zusätzliche Meßstrahloptionen Der neue DMP bietet erweiterte Meßfähigkeiten durch drei verschiedene Meß(strahl)optionen. Normaler Modus ist die Standardeinstellung und kann für die meisten Meßarbeiten verwendet werden. Schmaler Modus wird verwendet, wenn eine hohe Genauigkeit erforderlich ist, oder wenn Störungen durch periphere Gegenstände eliminiert werden müssen.
Page 31
Höhere mathematische Genauigkeit Der Dimension Master Plus (DMP) ist mit einem neuen, leistungsstarken Chip ausgestattet, wodurch Kalkulationen schneller und mit höherer Genauigkeit durchgeführt werden. Erweiterte Funktion der Tasten [Area] und [Volume] Wenn Fläche und Volumen berechnet werden, wird das Ergebnis in der zuletzt verwendeten Maßeinheit angezeigt.
Page 32
Größere Speicherkapazität Es wurden extra Speicherregister hinzugefügt, in denen Längen-, Breiten- und Höhenmessungen gespeichert werden können. Die so gespeicherten Werte können leicht abgerufen und für andere Messungen, z.B. zur Berechnung von Fläche und Volumen, verwendet werden. Erweiterte Anzeige Das LCD-Display des DPM wurde erweitert, so daß...
Page 33
[Rcl] Wird in Verbindung mit anderen Tasten gedrückt, um gespeicherte Werte oder Einstellungen anzuzeigen. [Convert] Rechnet zwischen den Maßeinheiten um und bietet Zugriff auf sekundäre Funktionen. Durch wiederholtes Drücken werden die verfügbaren Maßeinheiten angezeigt: Linear: Foot/Inch, Foot, Inch, Yard, Meter Quadrat: Quadrat-Foot, Quadrat-Yard, Quadratmeter Kubik:...
Page 34
[M+] Speichert den angezeigten Wert. [Sq] Legt den Wert als "Quadratwurzel" fest. Bruchstrich. Zum Trennen von Nenner und Zähler. Durch Drücken von [Rcl] und [/] wird die aktuelle Brucheinstellung angezeigt. Weitere Funktionen in Verbindung mit der Taste [Convert] [Convert] in Verbindung mit . . . [÷] berechnet die Quadratwurzel.
Warranty Warranty Repair Service – U.S.A. Calculated Industries, Inc. (“CII”) warrants this product against defects in materials and workman- ship for a period of one (1) year from the date of original consumer purchase in the U.S. If a defect...
Page 36
If you cannot reasonably have the product repaired in your area, you may contact CII to obtain current product repair information and charges, in- cluding freight and duties. Calculated Industries, Inc. 4840 Hytech Drive Carson City, NV 89706 U.S.A Tel: 775/885-4975 • Fax: 775/885-4949 http://www.calculated.com •...
Page 37
Disclaimer CII MAKES NO WARRANTY OR REPRESENTATION, EITHER EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCT’S QUALITY, PERFORMANCE, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE. AS A RESULT, THIS PRODUCT, INCLUDING BUT NOT LIMITED TO, KEYSTROKE PROCEDURES, MATHEMATICAL ACCURACY AND PREPROGRAMMED MATERIAL, IS SOLD “AS IS,”...
Page 38
Looking for New Ideas Calculated Industries, Inc. (CII), a leading manu- facturer of special function calculators and digital measuring instruments, is always looking for new product ideas in these areas. If you have one or if you have any suggestions for improvements to this product or its User’s Guide,...
Need help?
Do you have a question about the Dimension Master Plus and is the answer not in the manual?
Questions and answers
What is the setting for measuring room temperature?
The Dimension Master Plus does not have a specific setting for measuring room temperature. However, it uses automatic temperature compensation to ensure measurement accuracy within a temperature range of 32ºF to 100ºF (0ºC to 38ºC). If the internal temperature differs from the ambient temperature, you may compensate by adding or subtracting 1% of the measured distance for each 10ºF (5.5ºC) difference.
This answer is automatically generated