Possible Failure And Its Solution - Lincar 702A-G Using Instructions And Maintenance

Residential space heating appliances fired by wood
Table of Contents

Advertisement

Available languages

Available languages

Possible failure and its solution

3.4
DEFECT
Windows fire door
and/or combustion
chamber are dirty of
soot.
Not regular draft
Too much dark
fumes from the
exhaust
Fume escape from
the stove
Every intervention has be done from qualify staff !
CORISIT S.r.l. is not responsible for damages to things or people due to a wrong installation,
equipment tampering, improper use, bad maintenance or no observation of normative in force.
If considerate appropriate, CORISIT S.r.l. reserves the right to make modifications without
notice and in every moment.
Some particulars and accessories illustrated in this handbook are not mass produced item so
its extra costs are to check at contract release.
IT IT IT IT- - - - GB
GB- - - - FR
GB
GB
CAUSE
− Low draft <10 Pa.
− Wrong regulation.
− Too much combustible
introduced.
− Combustible with high
humidity level.
− Not good quality
combustible.
− Flue / exhaust fumes
unsuitable or dirty.
− Stove is dirty inside.
− Stove light on with green
wood/ too humid.
− Fume exhaust partially
obstructed.
− The fire/ash door is open
while the fire is burning.
− Draft insufficient <10 Pa.
− Not correct regulation during
ignition operation
− The stove should be cleaned.
38/76
FR- - - - ES
ES mod. 702A-G -702A-GL 2019
FR
FR
ES
ES
SOLUTION
− Check that the exhaust fumes
tube is not obstructed.
− Modify the flue : increase the
section, the height, verify the
isolation. Eliminate or reduce to
the minimum horizontal sections
and curve. Verify the section and
the height of the chimney cap
(see reflux zone)
− See charter "Regulations" and
"Fuel to be utilized"
− Reduce the quantity of fuel.
− Use dry and weathered wood
only.
− Read charter "Combustibile".
− Require chimney sweep
intervention.
− Clean the stove.
− Use weathered and better quality
of wood.
− Call the assistance service/
chimney sweep.
− Verify the correct closure of the
doors and the seal of the gaskets
− Modify the flue : increase the
section, the height, verify the
isolation. Eliminate or reduce to
the minimum horizontal sections
and curve. Verify the section and
the height of the chimney cap
(see reflux zone)
− Require chimney sweep
intervention.
− See charter "Regulations" and
"Fuel to be utilized"
− Clean the stove