Installation - OBS RPL-X Series Installation, Operation And Maintenance Manual

Regulator pressure liquid
Table of Contents

Advertisement

Installation, operation, and maintenance manual
RPL-X-P04-MA-IOM
2 I
NSTALLATION
The function of the RPL-X-series is virtually unaffected by its orientation. The RPL-X-M-versions (Manually
operated) is typically mounted with clamps around the body. Some of the RPL-X-series regulators are available
with actuator.
To mount/dismount regulator and actuator, the wheel with gear (7) must be removed.
First remove cover (2) held by 4x M5x10 screws (1). Then remove plastic cover (3) by using a bent pin. Undo
the M10 nut (4) and lift of disc (5) and wheel (7). Be careful not to lose the key (6) or the plastic disc inside the
wheel. Regulator and actuator can now be removed by undoing M4x20 screws (8) and M5x12 screws (9). The
small gear (13) is mounted on top of actuator with disc (12) and M4x10 screw (10).
Installing is done by the same operations in backwards order. Lock M10 nut with medium strong Loctite
Figure 5: Actuator assembly
7 av 15
Document:
RPL-X-P04-MA-IOM
Version:
Issue date:
04
25.01.2022