Page 1
Hardware Manual TP50 / TP80 / TP130 / TP350 Revision E Keep all manuals belonging to this product during its life span. Pass all manuals to future owners and users of this product. This English version is the original version of the product manual.
The user must have read and understood this documentation before carrying out any operation on Tri- amec Motion AG hardware. Please contact Triamec Motion AG in case of missing information or doubt regarding the installation procedures, safety or any other issue.
Caution cur if an external brake resistor is missing or improperly dimensioned. 2 Product Description The TP50, TP80, TP130 and TP350 devices complement the TSD80, TSD130, and TSD350 drive series. TP devices contain: A three phase rectifier, in-rush current limiter ...
Product Description 2.1.1 Internal or external brake All power supplies can be ordered with an internal brake resistor (standard) or a connector for an exter- nal brake resistor (order code BRK). 2.1.2 Phase Fail Detection The power supplies can be ordered in two variants: ...
3 Technical Specifications 3.1 Environmental Conditions 3.1.1 Transport and storage conditions During the transport and the storage, the device must remain inside their original packaging which complies with the ESD standard. The transport conditions must respect the class 2K3 of the IEC 60721-3-2 standard (temperature be- tween -25°C (-13°F) and +70°C (+158+C), and humidity <95% without condensation) and ...
Technical Specifications Electrical Specifications 3.2 Electrical Specifications All the specifications are given for an ambient temperature ranging from +10°C (50°F) to +40°C (104°F) . TP50 TP80 TP130 3-phase or 3-phase AC voltage (L-L) 31...35 ± 10% 44...56 ± 10% 44...86± 10%...
Page 9
Technical Specifications Electrical Specifications All the specifications are given for an ambient temperature ranging from +10°C (50°F) to +40°C (104°F). TP350 3-phase or 3-phase AC voltage (L-L) 44...230 ± 10% V AC (1-phase) 1-phase AC voltage 44.. 230 ± 10% V AC AC-Line input...
Caution Mains input voltage drops at maximum load on the Dc-Bus side may break Caution the internal fuse due to capacitor recharging. Consult Triamec on how to avoid this problem. 3.3 AC-Line The device must be connected to an electrical AC network ...
Technical Specifications EN 61800-5-1 3.6 EN 61800-5-1 The TP devices conform to EN 61800-5-1 (2008), overvoltage category III. Safe electrical separation ac- cording to EN 61800 is guaranteed between the power circuit and 24V and Earth. 3.7 EN 61800-3 The interference suppression filter in this device complies to EN 61800-3 C2 under the following condi- tions.
Technical Specifications Overvoltage involved the internal brake resistor might reach its thermal limit. It will turn off and the DC-bus voltage might increase further until the drives turn off. Then the axis does not stop and might cause mechanical damage. This failure is avoided by using an external brake resistor or reducing the deceleration of the drives.
Page 13
Technical Specifications LED Diagnostics and Status Green LED Red LED Status Output Discharging DC-Bus flashing short Brake active [according to device state] Overvoltage flashing long Brake open [according to device state] flashing 1 times then pause Brake short (*) [according to device state] flashing 2 times then pause Over-temperature [according to device state]...
Mounting and Wiring Mounting and Wiring 4 Mounting and Wiring The device should be protected against any splashes of liquid and any contacts with smoke and dust. It must be installed inside a closed cabinet and mounted as mentioned below. 4.1 Dimensions Dimensions: Width...
Add a resistor 470Ohm/5W into each of the three phase power wires. Apply power for half an hour without enabling the drives. Then shut down and disconnect the device for 4 hours, remove the resis- tors and the TP is ready to use 4.5 Wiring and Connectors Mains Isolating Supply TP50-TP350 Mains Fuse Ferrite Switch Transformer...
Page 17
Mounting and Wiring Wiring and Connectors The following measures must be taken to ensure personal safety and EMC requirements There must be two connections to earth. Each must have at least the same diameter as the AC-Line wires. Danger Always connect first the protective earth (PE) to the dedicated screw in the Danger housing!
All Triamec Motion AG products are warranted for a period of 12 months from the time of installa- tion, or 18 months from time of shipment, whichever comes first. No other warranties, expressed or implied –...
Disclaimer This document is delivered subject to the following conditions and restrictions: This document contains proprietary information belonging to Triamec Motion AG. Such information is supplied solely for the purpose of assisting users of Triamec products. The text and graphics included in this manual are for the purpose of illustration and reference only.