Page 1
Disclaimer This document is delivered subject to the following conditions and restrictions: This document contains proprietary information belonging to Triamec Motion AG. Such information is supplied solely for the purpose of assisting users of Triamec products. The text and graphics included in this manual are for the purpose of illustration and reference only.
The user must have read and understood this documentation before carrying out any operation on Tria- mec Motion AG hardware. Please contact Triamec Motion AG in case of missing information or doubt regarding the installation procedures, safety or any other issue.
It is therefore not intended for direct connection to European 3x400VAC power lines. When using the TP150 for TS15x drives, the input must be limited to 1x or 3x110VAC. In a mixed config- uration with TS15x and TS35x drives, the TP150 must be used to ensure correct brake action.
3 Technical Specifications 3.1 Environmental conditions Transport and storage conditions During the transport and the storage, the power supply must remain inside their original packaging which complies with the ESD standard. The transport conditions must respect the class 2K3 of the IEC 60721-3-2 standard (temperature between -25°C (-13°F) and +70°C (+158+C), and humidity <95% without condensation) and ...
Caution Mains input voltage drops at maximum load on the Dc-Bus side may break Caution the internal fuse due to capacitor recharging. Consult Triamec on how to avoid this problem. 1 See chapter 3.3 2 Limited by an internal arrestor circuit.
3.3 AC-Line The power supply must be connected to an electrical network of overvoltage category 3 (refer to EN 61800-5-1 and UL 840 standards for more information) capable of delivering not more than 40kArms, symmetrical amperes (prospective current according to EN 60269-1).
every power supply, which is to be introduced around the three phase wires of the AC-Line. In some cases it might be beneficial to insert further blocking ferrites ( ) into the DC-Bus pairs. If doing so, make sure, every DC-Bus output of the power supply gets its own ferrite to prevent overheating of the ferrite. Other combinations of motors and cable might require a single stage line EMC filter or an insulated transformer between 3x400V line-in and TP350.
3.8 LED Diagnostics and Status AC-Line DC-Bus Brake Int Brake Ext Status No line power red flash Inrush limiter green green flash Ready green green AC-Line disturbance red flash green Discharging DC-Bus red flash green flash green flash Varistor broken all four LED moving red slow ( 1 per second) Internal brake active green...
4 Mounting and Wiring The power supply should be protected against any splashes of liquid and any contacts with smoke and dust. It must be installed inside a closed cabinet and mounted as mentioned below. 4.1 Dimensions Dimensions: Width 91 mm Height 205 mm Depth...
All Triamec Motion AG products are warranted for a period of 12 months from the time of installa- tion, or 18 months from time of shipment, whichever comes first. No other warranties, expressed or implied –...
Need help?
Do you have a question about the TP150 and is the answer not in the manual?