Chromalox PK405-18 Installation Instructions And Renewal Parts Identification

Ar (single phase) industrial thermostat

Advertisement

RENEWAL PARTS IDENTIFICATION
AR (Single Phase) Industrial Thermostat
NEMA-I Model
AR-LT
Moisture Resistant Model
© 2010 Chromalox, Inc.
Chromalox

Installation Instructions

and
3-3/8"
3-1/8"
C L
7/8"
7/8"
4-7/16"
5-1/16"
®
DIVISION
REFERENCE
DATE
Table A – Specifications
Temperature
NEMA I
Range
Model*
(˚F)
AR-115
AR-115A
0–100˚F
AR-115C
AR-214
AR-214D
5-7/8"
AR-215
60–250˚F
AR-215A
AR-219
AR-219D
AR-514
AR-515
200–550˚F
AR-515A
AR-519
AR-519D
AR-715
AR-715D
300–700˚F
AR-719
*Models equipped with Pilot Light are designated by the suffix "P" on the Model Number.
Models equipped with Knob Cover are designated by the suffix "KC" on the Model Number.
Models equipped with both a Pilot Light and a Knob Cover are designated by the suffix "PKC" on the
Model Number.
Models installed in a moisture resistant enclosure are designated by the suffix "LT" on the Model
Number.
Pilot Light nor Knob Cover available on LT models.
3/4" NPT Conduit Holes
7-1/16"
Figure 1
SERVICE REFERENCE
4
SECTION
SALES
(Supersedes PK405-17)
MARCH, 2004
Sensing Bulb
Approx.
Capillary
Dia.
Length
Style
(In.)
(In.)
5
0.375
4-3/8
4
0.250
5-5/32
5
0.375
4
9
0.188
10-3/4
4
0.250
7-5/16
5
0.375
3-5/8
9
0.188
11-1/2
5
0.375
3-11/16
9
0.188
12
2-21/32"
4-3/32"
(Refer to Specifications Table A)
AR
PK405-18
161-049287-001
Maximum
Length
A.C. Rating
(Ft.)
(Amps.)
7
2
12
10 Amp.
480 Vac
7
30 Amp.
15
120-277 Vac
7
2
250VA
7
120-277 Vac
(Pilot Duty)
15
7
7
2
7
15
7
15
7
2-21/32"
Bulb
Dia.
Length

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PK405-18 and is the answer not in the manual?

Questions and answers

Summary of Contents for Chromalox PK405-18

  • Page 1: Installation Instructions

    Chromalox Installation Instructions RENEWAL PARTS IDENTIFICATION AR (Single Phase) Industrial Thermostat NEMA-I Model AR-LT Moisture Resistant Model © 2010 Chromalox, Inc. ® Table A – Specifications NEMA I 3-3/8” Model* 3-1/8” AR-115 AR-115A AR-115C AR-214 AR-214D 5-7/8” AR-215 AR-215A AR-219...
  • Page 2 B. If control is a “–KC” model (knob cover), remove knob cover as in Figure 5. C. Set thermostat knob to OFF position and then remove knob by lifting knob from shaft (see Figure 6). D. Loosen two screws from end of base plate and remove ther- mostat cover (see Figure 7).
  • Page 3 Figure 17. For either method, the following general calibration procedures should be followed: 1. Remove knob cover, knob and thermostat housing as per instruc- tions 3, 4 and 5 under WIRING. WIRING Figure 6...
  • Page 4 AR-515 300-048518-011 AR-515A 300-048518-014 AR-519 300-048518-004 AR-519D 300-048518-027 AR-715 300-048518-006 AR-715D 300-048518-029 AR-719 300-048518-007 Please refer to the Chromalox limited warranty applicable to this product at http://www.chromalox.com/customer-service/policies/termsofsale.aspx. NEMA-I Models 213-018509-002 Thermostat Cover 080-024763-001 080-024763-001 080-024763-001 080-024763-001 080-024763-001 080-024763-001 080-024763-001 080-024763-001...

This manual is also suitable for:

Ar-115Ar-115aAr-115cAr-214Ar-214dAr-215 ... Show all

Table of Contents