Cleaning the spray arms
 Use a pointed object to push food
particles into the spray arm nozzles.
 Rinse the spray arm thoroughly under
running water.
Cleaning and care
Refitting the spray arms
 Refit the upper and middle spray
arms.
 Refit the lower spray arm and ensure
that the filter combination lies flat in
the base of the wash cabinet.
 Rotate the screw thread of the lower
spray arm clockwise until the arrow in
the viewing window points to the lock
symbol .
 Make sure the spray arms can rotate
freely.
Damage due to soiling entering
the circulation system.
The lower spray arm is used to se-
cure the filter combination. Without
filters, coarse soiling can enter the
circulation system and cause a
blockage.
Do not run a wash programme
without the lower spray arm or
without the filters.