Error codes
Error codes
* Even when the spa is turned off, the equipment will start in case of danger of frost damage.
DANSK BAD EM ILJØ
Status
No message in the display.
There is no electricity at the spa.
Unknown temperature.
"Overheating" - The spa is turned off. *
One of the sensors has measured a tempe-
rature above 47.8 ° C at the heater.
"Overheating" - The spa is turned off. *
One of the sensors has measured a tempe-
rature of 43.5 ° C in the water.
The spa is turned off. * The sensor in the
"A" socket does not work.
The spa is turned off. * If the message
changes with the temperature display, it
may be temporary. If messages flash alone,
the spa is turned off *.
The sensors are not in balance. If the
message changes with the temperature
display, it may be temporary. If messages
flash alone, the spa is off. *
There is a significant difference bet-
ween the measured temperatures at the
sensors. This can be a flow problem.
Persistent low water flow (Appears on the
fifth display of HL within 24 hours). The
heater is off, but other spa functions are
normal.
There may be too little water, poor flow or
air pockets in the heater. The spa is off for
15 minutes.
There is not enough water in the heater.
(Appears after third door message) The spa
is turned off. *
"Ice". There is a risk of frostbite.
Solution
The display will be turned off until the spa is powered.
All settings are saved until next time.
The current temperature only shows after approx. a
minute.
DO NOT GO IN THE WATER. Remove the cover and allow
the spa to cool. When the spa has cooled down again,
press any button to reset the display. If the display does
not reset, turn off the power and call for service.
DO NOT GO IN THE WATER. Remove the cover and allow
the water to cool. When the water reaches a tempera-
ture of 41.7 ° C, the display restarts automatically. If the
display does not reset, turn off the power and call for
service.
If this problem persists, call for service. The condition
may be temporary during overheating.
If this problem persists, call for service. The condition
may be temporary during overheating.
If this problem persists, call for service.
If the water level is normal, make sure there are no air
pockets in the pumps. If this problem persists, call for
service.
Do the same as with the HL message. Reset by pressing
any button. If this problem persists, call for service.
If the water level is normal, make sure there are no
air pockets in the heater Press a button to restart. The
message will turn off within 15 minutes. If this problem
persists, call for service.
Do the same as for the dr message. The spa does not
restart automatically. Press a button to restart.
Nothing needs to be done. All equipment starts automa-
tically regardless of the mode of the spa. The equipment
runs until four minutes after the sensors have measured
a temperature of 7.2 ° C or more.