IP network intercom terminal User Manual Summary Safety precaution Please abide by the warning and the relevant safety tips. Please take this manual in convenient place after you reading the guide for future reference. Warning The sign means there is potential safety hazard, when operate wrong may result in death or serious injury. The sign is used to remind user of this equipment is attached the important data of operation and maintenance.
If failure to comply with this provision, it will likely cause electric shock or fires. Product introduction IP network intercom terminal embedded IP Audio digital network audio technology of SPON proprietary intellectual property rights, it support the audio output, record output, alarm input and output, SD card broadcast etc. it can drive 16 piece panels.
IP network intercom terminal User Manual ①DC12V input interface Offer the 12V input voltage to machine ②Audio line output port This output port is the restored original audio signal, it can be used as the sound resource to amplifier or active speaker, it`s used to play the background music ③Record audio output port This port outputted voice is from panel microphone.
IP network intercom terminal User Manual (2)Detachable terminal (3.81-8P) 2 pcs (3)Power adapter (DC12V/2A) 1 pcs (4)Certification 1pcs (5)Instruction manual 1 pcs Wired (1)Make the power adapter one end connect to IP network intercom terminal DC12V port, and the other end connect to the power socket.
IP network intercom terminal User Manual (4) Make 2 piece detachable terminal(3.81-8P) install on IP network intercom terminal back panel as below picture. (5)Make the another end of the cable connect to the different equipment respectively as per below picture.. The wire selection Suggest use TCL CAT-5 or above wire.
IP network intercom terminal User Manual transmission distance). Connector wire standard: double –end 568B standard. Panel electrical parameters standby work current Less than or equal to 60 mA Maximum work current Intercom/receive broadcast :less than or equal to 400 mA standby voltage range More than 11V or less than 12V Intercom/the max voltage of receive broadcast :more than...
IP network intercom terminal User Manual distance (the distance between the panel and splitter should be less than 100 meters). Status light description The light will be red after power on, user can check the terminal executive task situation from the status indicator light Status light (color) Terminal status Red slow flash...
IP network intercom terminal User Manual 192.168.101, press the system configuration button to play the IP information when there is no network cable insert)then press Enter button. (2)Enter the user name and password in web page appeared login window interface (default user name and password are admin) (3)After press OK button to access into IP network intercom terminal web page Network parameters...
IP network intercom terminal User Manual Enter into “network parameters” setting, the relevant parameters list as follow: MAC Add The terminal Physical address Static IP: The default is static IP, the user defined IP address information . Connection Type Dynamic IP: Dynamic allocation IP address through DHCP IP Add The terminal itself IP address, The factory default IP address is 192.168.101 Subnet mask...
IP network intercom terminal User Manual Server version IP, when the terminal restart it can connect to the version server to Server version update program automatic. File server IP, it can download the server specified file contents to the SD card or File server built-in NandFlash through FTP .
IP network intercom terminal User Manual Intercom parameters Intercom coding, PCM means uncompressed data. ADPCM means Code mode compressed data.(small network data volume) Sampling rate The host intercom and monitoring sampling rate(8000Hz,22050Hz)。 Input volume The total volume for the host intercom input (0~15,6 degree is 0dB) The host intercom audio output mode (the line output lie in the main board, the speaker in the panels) Audio output...
IP network intercom terminal User Manual Alarm input parameters The alarm input status when without alarm input, this status decided the State alarm mode(open circuit alarm or close circuit alarm) When the alarm input is trigged ,the configuration need to link Alarm input linkage corresponding alarm output or not Audio output linkage...
IP network intercom terminal User Manual Modify password It can modify the login Web page account and password in WEB manage parameters. Modify port Web manage port: In order to visit this Web page port, if it’s not 80 port, please add the corresponding port when visiting this device Web page.(eg: the device port is 999,the visit add should be: http://xxx.xxxx.xxx.xxx:899)...
IP network intercom terminal User Manual Major parameters Restore factory setting All the device setting parameters recover to the factory default state Uploading correct All the device setting parameters recover to the last normal logining status setting Export the system Export the current system configuration files parameters Import the system...
Warning tone The prompt tone audio file is stored in SD card or built –in SPON folder short circuit input of NandFlash. 001 and short circuit input.002 this two subfiles, the terminal will play audio files of short circuit.001 folder (play the latest store audio files)when the alarm input 1 closed, the terminal will play audio files of short circuit.002 folder when the alarm input 2 closed.
Page 19
IP network intercom terminal User Manual The 4th step: Please choose the required import audio files from the “computer audio file list”, ,then choose the required update SD card terminal from the “SD card catalogue”, choose the audio files stored path in the catalogue, then click “file” button, the computer’s files will display to the SD card catalogue, as below: The 5th step: After finished the 4th step, please imported audio files in red “...
IP network intercom terminal User Manual Malfunction test Why the terminal can’t normal login to the server? 1、Check the software server and the main control is normal opened or not. It`s required to close all firewall before open the software server (including system built-in firewall and other antivirus software firewall). 2、Check the network connection is normal or not.
Only for private use, downloading and printing of the manual is not prohibited when it is spreading on internet and media. No part of the manual is allowed to be reproduced or used for commercial purpose. And SPON shall take no responsibility for any losses or damages caused by the illegal reproduction and conversion of the manual.