ELECTRICAL ADJUSTMENT INSTRUCTIONS
Note: Electrical adjustments are required after
replacing circuit components and certain
mechanical parts. It is important to perform
these adjustments only after all repairs and
replacements have been completed.
Also, do not attempt these adjustments unless
the proper equipment is available.
Test Equipment Required
1. NTSC Pattern Generator
2. Remote control unit
3. Color Analyzer
How to set up the service mode:
Service mode:
1. Turn the power on.
2. Press [0], [6], [2], [5], [9], [6] and [Info] buttons on
the remote control unit in the order. The following
screen appears.
" * " differs depending on the models.
System Information
Clear
Options
RGB Align
NVM Editer
NVM Copy
6-1
SAM
Op Hour: *****
Main SW ID:*******-*.**
ERR: *** *** *** *** ***
OP1: *** *** *** *** ***
OP2: *** *** *** *** ***
PL9.0EA