205,000btu/hr space warmer kerosene/ diesel heater with wheels

Advertisement

Motor runs, but the heater does not ignite
and locks out after a short time
Power indicator light is flashing
Flames come out of flue outlet
Heater stops during operation
Heater stops during operation
Power indicator light is flashing
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts
without prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
Empty fuel tank, dirty or wrong fuel
Fuel filter clogged
Air leaks on oil line
Burner nozzle clogged
Fuel viscosity increased at low temperature
Insufficient airflow into combustion chamber
Compressor pressure too high
The room temperature set on room thermostat has
been reached
Flame failure
Bad combustion
Reduced airflow
Overheating
01284 703534
sales@sealey.co.uk
Original Language Version
Remove wrong or dirty fuel
Fill tank with clean diesel or kerosene
Clean or replace fuel filter
Check hoses, tighten connections, if
necessary replace
Clean nozzle with compressed air,
replace if necessary
Mix diesel with 10-20% kerosene
Check air inlet, fan, motor
Check air pressure , adjust if needed
Normal operation
To start turn temperature control knob
clockwise onto a higher setting
Check and remove the cause of the
malfunction
To reset, turn On/Off switch to 0 and then
to I
Call technical service if problem persists