Dehumidifying

1
Press
to turn on the power.
- It takes 30 minutes of continuous operation to
reach the desired humidity level the first time
the product is used.
- The display shows the current humidity level.
2
Press
/
to change humidity.
- The desired humidity level can be set in 5-
percent increments from 30-80%.
- The display shows the desired humidity level
while it is being set, then reverts to the current
humidity level after 5 seconds.
- The current humidity level is displayed in 5-
percent increments from 25-90%.
If the humidity level is outside the range, the
display continues to show either 25% or 90%.
3
Press
to change the fan speed.
The fan speed has two levels: low or high.
4
Press
to turn off the product.
!
NOTE
• If the product is restarted immediately
after being shut down, to protect the
compressor there is a 3-minute delay
until the compressor begins operating.
• It is normal for the compressor to cause
the product to vibrate while starting or
stopping.
Copyright ©2016 LG Electronics. Inc. All right reserved.
Only for training and service purposes

Setting the Timer

1
Press
to turn on the power.
2
Press
to set the automatic shut off time.
- Press the button repeatedly to increase the
time until shut off in 1-hour increments up to
12 hours.
3
Press
to cancel the Timer function.
- Press the Timer button repeatedly until the
Timer light turns off.
!
NOTE
Empty the drain water bucket before
setting the Timer function.
If the water bucket becomes full during the
Timer function, the Bucket Full light goes
on and dehumidification stops.

Safety Standby Light

- After 23 hours of continuous operation, the red
Safety Standby light turns on for one hour and the
fan and compressor shut off to prevent product
malfunction.
- After an hour with the fan and compressor shut
off, the Safety Standby light turns off and the fan
and compressor automatically restart.

Bucket Full Light

- Empty the water bucket within three minutes of
the Bucket Full light turning on.
- After the light turns on, the fan operates for an
additional three minutes to remove remaining
condensed water and then the product shuts off.
- See Emptying the Water Bucket for further
instructions.