OTHER TECHNICAL DATA
TOTAL POWER:
Electric supply:
Appliance cate-
gory:
Gas connection:
Appliance class:
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
Multi Crown
Semi-rapid
Auxiliary
GAS BURNERS FOR LPG G30/G31 28-30/37 mbar
NORMAL
BURNER
POWER kW
Multi Crown
3,55
Semi-rapid
2,0
Auxiliary
1,0

ENERGY EFFICIENCY

PRODUCT INFORMATION ACCORDING TO EU 66/2014
Model identification
Type of hob
Number of gas burners
Energy efficiency per gas burner
(EE gas burner)
Gas original:
G20 (2H) 20 mbar
Gas replace-
G30 (3+) 28-30 mbar
ment:
G31 (3+) 37 mbar
220-240 V ~ 50-60 Hz
II2H3+
G 1/2"
3
NORMAL POWER kW MINIMUM POWER kW
4,0
2,0
1,0
MINIMUM
POWER kW
1,4
0,45
0,33
Left rear - Semi-rapid
Right rear - Semi-rapid
Left front - Multi crown
Right front - Auxiliary
1,4
0,45
0,33
NOMINAL GAS FLOW g/h
INJECTOR
MARK
G30 28-30 mbar
095
258
71
145
50
73
9 kW
621 g/h
611 g/h
INJECTOR MARK
146
96
70
G31 37 mbar
254
143
71
ZGH62424XA
Built-in hob
4
57.5%
57.5%
60.6%
not applicable
15