Regulatory and License Information
Regulatory Information
Communications Regulatory Information
Notice for the United Kingdom
The HP Brio PC is approved under approval number NS/G/1234/J/100003 for indirect connection to Public
Telecommunication systems within the United Kingdom.
This section contains important information for U.K. users of the HP PC communications board. It provides instructions on the correct
installation and use of the communications board in order to maintain the type approval granted.
Installation of the Communications Board
Electrical Power
Before making connections, check the safety levels on the various interfaces:
Telephone line connector = TNV
ISA connector = SELV
These indications are classified as per security standard EN 60-950/A2 10/93
SELV: Very Low Safety Voltage
TNV: Telecommunications Network Voltage, voltages in compliance with standard EN 60950 criteria.
The HP PC communications board is approved only for installation in a 'host' computer (PC) and with host attachment, which are either type
approved for such apparatus, or covered by a General Approval.
It is a condition of type approval that the power required by the host and the total of all other adapter cards installed within the host apparatus,
together with any auxiliary apparatus, does not exceed the power specification as stated in the Online Reference Guide.
The equipment is to be installed such that, with the exception of the connections to the host, clearance and creepage distances shown in the
table below are maintained between the board and any other assemblies which use or generate a voltage. The larger distance shown in
brackets applies where the local environment within the host is subject to conductive pollution or non-dry conductive pollution which could
become conductive due to condensation.
Failure to maintain these minimum distances would invalidate the approval.
In case of doubt, please obtain advice from a competent telecommunications safety engineer.
For a host or other expansion board fitted in the host, using or generating voltages greater than 300 Vrms or Vdc, advice from a competent
telecommunication safety engineer must be obtained before installation of the relevant equipment.
It is a condition of approval that the power required by the host and the total of all adapter boards installed within the host environment,
together with any auxiliary apparatus, does not exceed the power specification as stated in the Online Reference Guide.
50
Clearance
Creepage
(mm)
(mm)
2.0
2.4 (3.8)
2.6
3.0 (4.8)
4.0
5.0 (8.0)
4.0
6.4 (10.0)
Voltage used or generated
Up to 50 Vrms or Vdc
Up to 125 Vrms or Vdc
Up to 250 Vrms or Vdc
Up to 300 Vrms or Vdc