5.1.6. Reference
(White Balance Adj. coordinate and color
temperature)
▪ Luminance: 204 Gray, 80IRE
▪ Normal line
model: (normal line)LN5xxx, LA6xxx, LA7xxx, LA8xxx
Cool
H/R Time(Min)
x
269
1
0-2
281
2
3-5
280
3
6-9
279
4
10-19
277
5
20-35
275
6
36-49
273
7
50-79
271
8
80-119
270
9
Over 120
269
▪ Aging chamber line
(Aging chamber) Model : LN5xxx, LA6xxx, LA7xxx, LA8xxx
▪ Standard color coordinate and
CA-210(CH-14) – by aging time
Cool
H/R Time(Min)
x
269
1
0-5
280
2
6-10
276
3
11-20
273
4
21-30
270
5
31-40
267
6
41-50
266
7
51-80
265
8
81-119
264
9
Over 120
263
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Medium
Warm
y
x
x
y
273
285
293
313
290
297
310
322
288
296
308
321
287
295
307
320
284
293
304
318
280
291
300
316
277
289
297
314
275
287
295
312
274
286
294
311
273
285
293
310
temperature using
Medium
Warm
y
x
x
y
273
285
293
313
288
296
308
321
283
292
303
317
278
289
298
314
275
286
295
311
272
283
292
308
270
282
290
307
269
281
289
306
267
280
287
305
266
279
286
304
5.2. Option selection per country
5.2.1. Overview
(1) Tool option selection is only done for models in Non-USA
North America due to rating
(2) Applied model: LA32B Chassis applied to CANADA and
MEXICO
5.2.2. Country Group selection
x
(1) Press ADJ key on the Adj. R/C, and then select Country
329
Group Menu
(2) Depending on destination, select US, then on the lower
342
Country option, select US, CA, MX.
340
Selection is done using +, - KEY
339
(3) Using DFT(Auto)
※ PC (for communication through RS-232C) -> UART Baud
336
rate : 115200 bps
332
Command : ah 00 00 DATA(Area Number(hexadecimal))
329
ITEM
327
AREA OPTION1
326
325
5.2.3. Tool Option inspection
▪ Press Adj. key on the Adj. R/C, then select Tool option
Model
Module
x
32LN5300-UB
LGD
329
47LN5400-UA
LGD
340
55LN5400-UA
LGD(POLA)
335
50LN5400-UA
LGD
330
42LN5400-UA
LGD
327
42LN5300-UB
LGD
324
42LN5300-UB
AUO
322
42LN5300-UB
LGD(POLA)
321
39LN5300-UB
CMI(POLA)
319
39LN5300-UB
AUO(POLA)
318
32LN5300-UB
CSOT(POLA)
32LN530B-UB
LGD
32LN530B-UB
LGD(POLA)
32LB530B-UA
LGD(POA)
※ Tool option can be reconstructed by Software
5.3. Ship-out mode check (In-stop)
- After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode
- 14 -
DATA(Area Number)
0
USA
1
CANADA
2
MEXICO
Tool
Tool
Tool
option1
option2
option3
545
41478
37004
1569
33286
37004
2065
33286
37004
1825
33286
37004
1313
33286
37004
1313
41478
37004
9505
41478
37004
1297
41478
37004
5137
41478
37004
9233
41478
37004
4625
41478
37004
545
45574
37004
545
45574
37004
529
49730
24716
LGE Internal Use Only
AREA
Tool
option4
12031
46847
40703
48895
36607
03839
03839
03839
03839
03839
03839
03839