Service Manual – Alpha McDonald's Fresh-Trac
Important Safeguards/Conventions
This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance should be performed by an
authorized Wilbur Curtis service technician.
• Do NOT immerse the unit in water or any other liquid
• To reduce the risk of fire or electric shock, do NOT open service panels. No user serviceable parts inside.
• Keep hands and other items away from hot surfaces of unit during operation.
• Never clean with scouring powders, bleach or harsh chemicals.
Symbols
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
The Curtis Alpha G3 is Factory Pre-Set and Ready to Go... Right from the Box.
Following are the Factory Settings for the Alpha Fresh-Trac:
• Brew Temperature = 202°F
• Brew Volume = Set to vessel requirements (60 oz).
System Requirements:
• Water Source 20 – 90 PSI (minimum flow rate of 1 GPM)
• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model.
SETUP STEPS
1. The unit should be level (left to right - front to back), on a secure surface.
2. Connect the water line to the water inlet fitting on the rear of the unit. Water volume flow to the machine should be consistent. Use
tubing sized sufficiently to provide a minimum flow rate of 1 gallon per minute.
NOTE: A water filtration system must be used to help maintain trouble-free operation. Air must be purged from the cartridge prior to
connection to equipment. In areas with extremely hard water, we highly recommend the use of a Curtis approved water filter. For our
full line of filters, please log on to www.wilburcurtis.com.
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so that the unit can be moved
for cleaning.
2. This unit must be installed with adequate backflow protection to comply with applicable federal, state and local codes.
3. Water pipe connections and fixtures directly connected to a portable water supply shall be sized, installed and main-
tained in accordance with federal, state, and local codes.
3. Connect the unit to electrical outlet with appropriate amperage rating (see serial tag on machine).
4. Once power has been supplied to the unit, flip the toggle switch to the 'ON' position (located on the rear of the unit), the water tank will
begin to fill. When the water level in the tank reaches the probe, the heating element(s) will turn on.
5. Water in the heating tank will require approximately a half hour before reaching operating temperature (factory setting of 202°F). When
the unit reaches operating temperature, it will display "READY TO BREW".
BREWING INSTRUCTIONS
1. The brewer should be ON. Confirm this at the rear toggle switch, then press the ON/OFF button. Ready-to-Brew should be displayed.
2. Place an empty decanter on warmer plate.
3. Place a new paper filter into the brew cone.
4. Pour the proper amount of ground
coffee into the brewcone.
C
C
ilbur
urtis
ompany
5. Slide the filled brewcone into the
rails on the coffee brewer.
, i
.
nC
6. Press the BREW button on the
control panel to start brewing.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Alpha McDonald's Fresh-Trac ALP3GT15A826 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wilbur Curtis Alpha McDonald's Fresh-Trac ALP3GT15A826

  • Page 1 ilbur urtis ompany Service Manual – Alpha McDonald’s Fresh-Trac Important Safeguards/Conventions This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance should be performed by an authorized Wilbur Curtis service technician. • Do NOT immerse the unit in water or any other liquid • To reduce the risk of fire or electric shock, do NOT open service panels. No user serviceable parts inside. • Keep hands and other items away from hot surfaces of unit during operation. • Never clean with scouring powders, bleach or harsh chemicals. Symbols WARNINGS – To help avoid personal injury Important Notes/Cautions – from the factory Sanitation Requirements The Curtis Alpha G3 is Factory Pre-Set and Ready to Go… Right from the Box. Following are the Factory Settings for the Alpha Fresh-Trac: Model Included: • Brew Temperature = 202°F • Brew Volume = Set to vessel requirements (60 oz). • ALP3GT15A826 System Requirements: • Water Source 20 – 90 PSI (minimum flow rate of 1 GPM) • Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model. SETUP STEPS CAUTION: 1. The unit should be level (left to right - front to back), on a secure surface.
  • Page 2: Enter Program Mode

    Your Curtis G3 System is Factory Pre-Set for Optimum Performance. After connection to water and power; the rear toggle switch must be on. You will hear a beep sound, indicating power is available to the controller. <ALP3/4/5> CURTIS CURTIS The control displays . Press ON/OFF button and the screen will display . After three seconds, is displayed. CURTIS FILLING CURTIS Water will fill the tank (approximately 2-3 minutes depending on water flow rate). When the proper level is reached will appear on the screen. It takes approxi- HEATING mately 20 minutes to reach setpoint temperature of 202°F. Control will display when temperature reaches the setpoint (202°F). Unit is now ready to brew. Enter Program Mode Turn off (dark display) by pressing ON/OFF button (yellow). Press and hold BREW button (green) and then press and release ON/OFF button (yellow). Continue holding BREW button. Display will read , wait until is displayed Enter the 4-digit access code, the digits 1-4 cor- ENTERING PROGRAM ENTER CODE MODE – – – – respond to the buttons (see illustration below). The default code set at the factory is 1-2-3-4. Then will be displayed. PROGRAM MENUS < SELECT > All programming selections are performed with the three center buttons.
  • Page 3 PROGRAM MENUS Cold Brew Lock (Factory set to 15º) Press  to select, < or > to select desired setting (CBL 5 or 15),  to set. The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is within 5 degrees of set point, next is within 15 degrees of set point for the Ready to Brew message, however it will brew at any temperature. Master Reset Press  to display Are You Sure? Then < for Yes, > for No. Brewer factory defaults are then reset. Service Call (Phone number Factory set to 1-[800] 000-0000x) Press  to display number and change number or < to move place and EX to exit when complete This number will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR. Access Code (Factory set to 1-2-3-4) Press  to display number and change number, (the range is 1 to 4) or < to move place and ex to exit when complete. Banner Name (Factory set to McDONALD’S) Press  to display letters and change letters or < to move place and EX to exit when complete. This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner Name. Warmer Auto OFF (Factory set to Disable) Press  to Select. Press < or > to move to desired time and then  to set. Timer range is OFF, 2 hours, 3 hours, and 4 hours. P-Maintenance (Factory set to OFF) Press  to select. To turn on, press < or > set gallons brewed. The range is from Off to 3000 gallons. Press  to exit. When the number of brews reaches the set amount, P-Maintenance will display on the screen. Beeper On/Off (Factory set to ON) Press  to display ON or OFF. Pressing either < or > to toggle between on and off. Press  to set. Pulse Brew (Factory set to Pulse D [1 pulse of 40 sec on, 5 sec off, 2 pulses of 40 sec on, 5 sec off] ). Press  to select, < or > to select OFF or one of five pulse patterns (A to E) . Guidelines for Pulse Brew: This feature allows tuning of the coffee flavor. The pot level should always be set first with this option OFF. Depending on your grind profile and water condi- tions, the five Pulse Brew options help “tune” or change the coffee flavor. Filter Pack type coffees typically extract better with the A and B pulse setting. Decaf- feinated coffees typically extract better with the B pulse setting. High-Yield coffees typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used to suit your taste profile. There are two additional settings (D and E) that allow you to manually set the ON TIME pulses and OFF TIME. If Pulse Brew is selected (ON), Cold Brew Lock is set to within 15ºF of set point and Cold Brew Lock disappears from the list of program selections. When Pulse Brew is ON, Pre-infusion disappears from the list of program selections. Display Brew Time (Factory set to ON). Press  to display ON or OFF. Pressing either < or > toggles between on and off. Press  to set. When on, this feature will appear when the brew button is pressed. The brew time will count down. Drip-Out Mode (Factory set to 1 min) Press  to select. Press > to increase time (to a maximum of 5 minutes) or < to decrease the time and turn OFF. Time counts up in 5 second increments. Press  to set.
  • Page 4 INSTRUCTIONS FRESH-TRAC TIMER These instructions will explain the operation and maintenance of the Fresh-Trac coffee timer. This timer will allow the user to track the freshness of coffee brewed into glass decanters. Fresh-Trac is only available with Curtis Alpha G3 brewers. The Fresh-Trac decanter is dish-washer safe. The expected battery life in the light unit is two years.
  • Page 5: Transmitter Range

    INSTRUCTIONS FRESH-TRAC TIMER TRANSMITTER RANGE The most effective signal range of the Fresh- Trac transmitter is 230º. This is shown as a top view in the illustration. ROUGH-IN DRAWING...
  • Page 6 ILLUSTRATED PARTS LIST ALPHA G3...
  • Page 7 ILLUSTRATED PARTS LIST ALPHA G3 ITEM № PART № DESCRIPTION WC-6812 WARMER, ASSY TOP ALP3GT WC-13164 HARNESS ASSY, WARMER ALPGT UPPER WARMER WC- 889-101 VALVE, DUMP LEFT 120V 12W WC-37379 KIT, SPRAYHEAD FITTING WC- 774-108* CONTROL MODULE, FRESH TRAC MCDONALDS ALP WC-390178 LABEL, UCM OVERLAY ALP3GT WITH QR CODE CURTIS LOGO WC-1809* FAUCET, PS/HSP SERIES HOT WATER 1/2-20 UNF WC-5853-102 COVER, TOP HEATING TANK WC-43062* GASKET, TANK LID WC-4320 O’ RING, 1/2” I.D. WC-5502-01* KIT, PROBE, ASSY WATER LEVEL W/HEX FITTING, O-RING & NUT WC-4394 GUARD, SHOCK HEATING ELEMENT WC-43055 GUARD, SHOCK RESET THERMOSTAT WC-1438-101* SENSOR, TEMPERATURE TANK WC- 522 * THERMOSTAT, HI LIMIT HEATER DPST 277V-40A WC-6267* TANK, COMPLETE ALP-DS/G3 220V WC-2401 ELBOW, 3/8 NPT x 1/4 FLARE PLATED WC- 826L*...
  • Page 8: Electrical Schematic

    ELECTRICAL SCHEMATIC...
  • Page 9 CLEANING 1. Brewer (Exterior) Cleaning Instructions: Use KAY QSR Glass & Multi-Surface Cleaner solution and a clean, sanitizer-soaked towel to remove soils from the exterior of coffee brewers. 2. Glass Coffee Pot Cleaning Instructions: a. Remove lid from the decanter. b.
  • Page 10: Product Warranty Information

    Curtis equipment that have not been purchased from the Wilbur Curtis Company, Inc. The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met. The warranty does not cover and is void under the following circumstances: 1) Improper operation of equipment: The equipment must be used for its designed and intended purpose and function.

Table of Contents