Page 1
All manuals and user guides at all-guides.com FOSTORIA INDUSTRIES, INC. 1200 North Main Street Fostoria, OH 44830-1911 Phone: 800-495-4525 Fax: 419-435-0842 www.fostoriaindustries.com A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) CONTENTS Specifications Page 2 IMPORTANT SAFETY...
All manuals and user guides at all-guides.com SPECIFICATIONS Portable Electric Heaters – UL file number E154159 Model Part number Volts Amps Fan Output Heat Output Dim A FES-1024-1CA 08860010 800 CFM 34152 BTUH 21” FES-1520-3A 08860110 41.5 800 CFM 51228 BTUH 21”...
Page 3
All manuals and user guides at all-guides.com YES - SERIES INSTALLATION ALL Fostoria YES models require some assembly. Four steps are required to complete the assembly and installation. Tools required: (2) ¾” socket or box wrenches. Step 1: Install (1) side rotating stop over bolt and into curved slot (as shown at Parts required: the two screws required to secure right) on each side of heater.
Page 4
All manuals and user guides at all-guides.com FES – SERIES ASSEMBLY Tools Required: (2) 7/16” socket or box wrenches. To position the handle at operating height: Bolts Step 1: Remove and keep the hardware securing the handle to the legs. Step 2: Raise handle until holes align with the upper holes in the legs.
All manuals and user guides at all-guides.com WIRING (continued) FES-1024-1CA YES-1024-1CA Models FES-1024-1CA and YES-1024-1CA are shipped with a cordset factory-installed. This cordset contains a plug for use with a 50A household range receptacle. The blade configuration on the plug included on these heaters is represented in fig.
Page 6
All manuals and user guides at all-guides.com WIRING (continued) FES-1524-1A YES-1524-1A FES-1524-1A YES-1524-1A T E R M IN A L B L O C K Attach feeder cable or cable kit to heater as shown in Ground lug is located photograph at right for the single-phase models Attach circuit conductors at directly below fuse as...
Page 7
All manuals and user guides at all-guides.com WIRING (continued) FES & YES 3- PHASE WIRING DIAGRAMS FES-1520-3A YES-1520-3A FES-1524-3E YES-1524-3E MAXIMUM OVERCURRENT PROTECTION 45 AMPS. USE COPPER WIRE ONLY MAXIMUM OVERCURRENT PROTECTION 55 AMPS. USE COPPER WIRE ONLY CABLE NOT INCLUDED CABLE NOT INCLUDED FES-1548-3E YES-1548-3E...
Page 8
All manuals and user guides at all-guides.com WIRING (continued) FES & YES 3-PHASE WIRING DIAGRAMS FES-3048-3A YES-3048-3A FES-3060-3A YES-3060-3A 480 VOLTS 60 HZ 3-PHASE MAXIMUM OVERCURRENT PROTECTION 40AMPS. MAXIMUM OVERCURRENT PROTECTION 45 AMPS. 30 KW USE COPPER WIRE ONLY USE COPPER WIRE ONLY. CABLE NOT INCLUDED CABLE NOT INCLUDED Page 8 of 24...
Page 9
All manuals and user guides at all-guides.com OPERATING INSTRUCTIONS Fostoria FES and YES series heaters are designed Note: ALL FES/YES models are equipped with to circulate room air across its heating elements to an internal over temperature limit designed to gradually increase room temperature.
Page 10
All manuals and user guides at all-guides.com FES REPLACEMENT PARTS LIST& EXPLODED VIEWS Description 1024-1CA 1520-3A 1524-3E 1548-3E 1560-3A 3048-3A 3060-3A Motor 8482001 (1) 8482001 (1) 8482001 (1) 8482002 (1) 8482003 (1) 8482004 (1) 8482005 (1) Bolt carriage ½-13 x 2-3/4 2470132 (2) 2470132 (2) 2470132 (2)
Page 11
All manuals and user guides at all-guides.com FES REPLACEMENT PARTS LIST& EXPLODED VIEWS Ref No. Description Part No. Handle 8480021 Washer flat ¼ 3442532 Screw ¼-20 x 2-3/4 2470032 Nut stop ¼-20 3440132 Axle 8481332 Cap plug 3409200 8480121 Washer rubber 2480200 Spacer 8480500...
All manuals and user guides at all-guides.com MAINTENANCE Other than periodic cleaning of the exterior, no maintenance is required for these heaters. ELECTRICAL SHOCK • Do not hose these units down. HAZARD • Remove dust and dirt from inside heater with compressed air.
Need help?
Do you have a question about the SUN-MITE FES Series and is the answer not in the manual?
Questions and answers