Download Print this page

TPI SUN-MITE FES Series Manual

Portable, suspended electric heater

Advertisement

Quick Links

A DIVISION OF
(FES-1524-3E shown)
IMPORTANT SAFETY
INFORMATION INSIDE
• Serious injury or death possible.
• Read, understand, and follow all
safety information and
instructions in this manual
before using or servicing this
product.
• Retain these instructions for
future reference.
Issue Date: 4-19-02 Rev. Date: 11-10-04 Rev. Level: 10
All manuals and user guides at all-guides.com
FOSTORIA INDUSTRIES, INC.
1200 North Main Street
Fostoria, OH 44830-1911
Phone: 800-495-4525
Fax: 419-435-0842
www.fostoriaindustries.com
FES - Series
Portable Electric Heaters
YES - Series
Suspended Electric Heaters
CONTENTS
Specifications
YES Installation
FES Assembly
Wiring
Operating
Replacement Parts Page 10,11
Maintenance
Limited Warranty Page 12
OIPM P/N 3420458
Page 2
Page 3
Page 4
Page 4,5,6,7,8
Page 9
Page 12
Page 1 of 24

Advertisement

loading
Need help?

Need help?

Do you have a question about the SUN-MITE FES Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TPI SUN-MITE FES Series

  • Page 1 All manuals and user guides at all-guides.com FOSTORIA INDUSTRIES, INC. 1200 North Main Street Fostoria, OH 44830-1911 Phone: 800-495-4525 Fax: 419-435-0842 www.fostoriaindustries.com A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) CONTENTS Specifications Page 2 IMPORTANT SAFETY...
  • Page 2: Specifications

    All manuals and user guides at all-guides.com SPECIFICATIONS Portable Electric Heaters – UL file number E154159 Model Part number Volts Amps Fan Output Heat Output Dim A FES-1024-1CA 08860010 800 CFM 34152 BTUH 21” FES-1520-3A 08860110 41.5 800 CFM 51228 BTUH 21”...
  • Page 3 All manuals and user guides at all-guides.com YES - SERIES INSTALLATION ALL Fostoria YES models require some assembly. Four steps are required to complete the assembly and installation. Tools required: (2) ¾” socket or box wrenches. Step 1: Install (1) side rotating stop over bolt and into curved slot (as shown at Parts required: the two screws required to secure right) on each side of heater.
  • Page 4 All manuals and user guides at all-guides.com FES – SERIES ASSEMBLY Tools Required: (2) 7/16” socket or box wrenches. To position the handle at operating height: Bolts Step 1: Remove and keep the hardware securing the handle to the legs. Step 2: Raise handle until holes align with the upper holes in the legs.
  • Page 5: Electrical Shock Hazard

    All manuals and user guides at all-guides.com WIRING (continued) FES-1024-1CA YES-1024-1CA Models FES-1024-1CA and YES-1024-1CA are shipped with a cordset factory-installed. This cordset contains a plug for use with a 50A household range receptacle. The blade configuration on the plug included on these heaters is represented in fig.
  • Page 6 All manuals and user guides at all-guides.com WIRING (continued) FES-1524-1A YES-1524-1A FES-1524-1A YES-1524-1A T E R M IN A L B L O C K Attach feeder cable or cable kit to heater as shown in Ground lug is located photograph at right for the single-phase models Attach circuit conductors at directly below fuse as...
  • Page 7 All manuals and user guides at all-guides.com WIRING (continued) FES & YES 3- PHASE WIRING DIAGRAMS FES-1520-3A YES-1520-3A FES-1524-3E YES-1524-3E MAXIMUM OVERCURRENT PROTECTION 45 AMPS. USE COPPER WIRE ONLY MAXIMUM OVERCURRENT PROTECTION 55 AMPS. USE COPPER WIRE ONLY CABLE NOT INCLUDED CABLE NOT INCLUDED FES-1548-3E YES-1548-3E...
  • Page 8 All manuals and user guides at all-guides.com WIRING (continued) FES & YES 3-PHASE WIRING DIAGRAMS FES-3048-3A YES-3048-3A FES-3060-3A YES-3060-3A 480 VOLTS 60 HZ 3-PHASE MAXIMUM OVERCURRENT PROTECTION 40AMPS. MAXIMUM OVERCURRENT PROTECTION 45 AMPS. 30 KW USE COPPER WIRE ONLY USE COPPER WIRE ONLY. CABLE NOT INCLUDED CABLE NOT INCLUDED Page 8 of 24...
  • Page 9 All manuals and user guides at all-guides.com OPERATING INSTRUCTIONS Fostoria FES and YES series heaters are designed Note: ALL FES/YES models are equipped with to circulate room air across its heating elements to an internal over temperature limit designed to gradually increase room temperature.
  • Page 10 All manuals and user guides at all-guides.com FES REPLACEMENT PARTS LIST& EXPLODED VIEWS Description 1024-1CA 1520-3A 1524-3E 1548-3E 1560-3A 3048-3A 3060-3A Motor 8482001 (1) 8482001 (1) 8482001 (1) 8482002 (1) 8482003 (1) 8482004 (1) 8482005 (1) Bolt carriage ½-13 x 2-3/4 2470132 (2) 2470132 (2) 2470132 (2)
  • Page 11 All manuals and user guides at all-guides.com FES REPLACEMENT PARTS LIST& EXPLODED VIEWS Ref No. Description Part No. Handle 8480021 Washer flat ¼ 3442532 Screw ¼-20 x 2-3/4 2470032 Nut stop ¼-20 3440132 Axle 8481332 Cap plug 3409200 8480121 Washer rubber 2480200 Spacer 8480500...
  • Page 12: Maintenance

    All manuals and user guides at all-guides.com MAINTENANCE Other than periodic cleaning of the exterior, no maintenance is required for these heaters. ELECTRICAL SHOCK • Do not hose these units down. HAZARD • Remove dust and dirt from inside heater with compressed air.