Location Of Your Dryer - GE DCCH43GAWW Installation Instructions Manual

Gas & electric dryer
Table of Contents

Advertisement

LOCATION OF YOUR DRYER

1. In an area exposed to dripping water or outside weather
conditions.
2. In an area where it will come in contact with curtains, drapes,
or anything that will obstruct the flow of combustion and
ventilation air.
3. On carpet. Floor
inch (2.54 cm).
1. A dryer installed in a bedroom, bathroom, recess or closet,
be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the
same closet as the Gas dryer.
3. Your dryer needs the space around it for proper ventilation.
CLOSET DOOR
be solid with a maximum slope of 1
4. A minimum of 120 square inches (774.2 square cm) of
opening, equally divided at the top and bottom of the door,
is required. Air openings are required to be unobstructed
when a door is installed. A louvered door with equivalent
air openings for the full length of the door is acceptable.
FRONT
Alcove
0 (0 cm)
Closet
1 (2.54 cm) 0 (0 cm) 0 (0 cm) 15 (38.1 cm)
Closet door ventilation required: 2 louvered openings each 60
square inches (387 square centimeters) — 3 inches (7.6 cm)
from bottom and top of door.
5. The following illustrations show minimum clearance
dimensions for proper operation in a recess or closet
installation.
4
SIDES
REAR
TOP
0 (0 cm) 0 (0 cm) 15 (38.1 cm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcch43eaww

Table of Contents